AbstractBackgroundLaboratory diagnosis of von Willebrand Disease (VWD) is complex. Reliance on laboratory testing can be problematic as different VWD screening panels, assays and methodologies can produce analytic variability in test results.ObjectivesTo compare the degree of imprecision among the VWD assays and within the platelet binding activity (PBA) assays, to determine the consensus among the VWD assays for correct classification of sample results, and to determine consensus among laboratories’ von Willebrand factor (VWF) multimer interpretations and final interpretations of the VWD panels.Patients/MethodsProficiency testing results from the North American Specialized Coagulation Laboratory Association (NASCOLA) submitted by laboratories from 2010 to 2019 for all normal, type (T) 1 VWD and T2 VWD samples were analysed.Results and ConclusionsImprecision was lowest for VWF antigen and highest for collagen binding activity (CBA) with median coefficient of variation (CV) of 12% (interquartile range (IQR) 7%) and 23% (IQR 21%) respectively. Within the VWF PBA assays, the gain‐of‐function mutant GP1b binding (VWF: GP1bM) methods had the least imprecision (CV 9%, IQR 10%). All assays, including the various PBA methods had excellent consensus. The majority of laboratories agreed that normal (median consensus‐82%, IQR 16%) and T1 VWD (median consensus‐100%, IQR 9%) samples had normal multimer distribution. Consensus among laboratories for final interpretations was excellent for normal samples (median 81%, IQR 8%), good for T1 VWD samples (median 59%, IQR 9%), and fair for T2 VWD samples (median 44%, IQR 21%). Consensus on final interpretation decreased as sample complexity increased.
Diagnostic laboratory standardization and validation of platelet transmission electron microscopy
SummaryIntroductionThe performance of factor XI activity (FXI) by laboratories in the North American Specialized Coagulation Laboratory Association proficiency testing program was analyzed.MethodsOver 10 years (2003–2013), 80 samples were distributed; 33–55 laboratories participated per exercise providing 3833 total responses. Analysis was performed on numeric results and qualitative classification of results.ResultsThe sample FXI levels ranged from 3.8 to 154.0 IU/dL. The overall interlaboratory average coefficient of variation (CV%) was 17.5%; the CV was higher for a sample with low (3.8 IU/dL) FXI. Results were correctly classified as abnormal (100%) for a sample with 3.8 IU/dL FXI and normal/borderline normal (97.7%) for 45 samples with 80 to < 140 IU/dL FXI. The classification was heterogeneous for samples with FXI of 50 to < 80 IU/dL. Six specimens were repeat‐tested from 2007 to 2013. The mean FXI was not significantly different in laboratories using the same method on both exercises, suggesting good intralaboratory precision over time. Univariate analysis of data from 2011 to 2012 did not find a consistent significant difference among the activators, analyzers, calibrators, and FXI‐deficient plasmas.ConclusionLaboratories generally performed well in assessment of FXI based on interlaboratory precision when FXI >30 IU/dL and on classification of samples with very low or normal FXI.
External Quality Assessment of Platelet Disorder Investigations: Results of International Surveys on Diagnostic Tests for Dense Granule Deficiency and Platelet Aggregometry Interpretation