Background: The stability of a suture knot construct has been realized as an important parameter that affects the strength of flexor tendon repairs. A novel 2-strand-overhand-locking (TSOL) knot, which is not commonly used in the clinical setting, recently was reported to increase repair strength and to decrease tendon gliding resistance in a 2-strand repair technique. The purpose of the present study was to investigate the effect of the TSOL knot on tendon repair strength and gliding resistance compared with a typical surgical knot in both 2-strand and 4-strand repair techniques using an in vitro turkey flexor tendon model. Methods: Sixty flexor digitorum profundus tendons from the long digit of the turkey foot were divided evenly into 4 groups and repaired with the following techniques: (1) a 2-strand modified Pennington repair with a square knot, (2) a 2-strand modified Pennington repair with a TSOL knot, (3) a 4-strand grasping cruciate repair with a square knot, and (4) a 4-strand grasping cruciate repair with a TSOL knot. Repaired tendons were tested for failure mode, gliding resistance, and repair strength at failure. Results: The repair strength and stiffness of the 4-strand repairs were significantly higher than those of the 2-strand repairs, regardless of knot type (p < 0.05). The repair strength at failure of the TSOL knot was significantly greater than that of the square knot in 2-strand repairs (p < 0.05) but not in 4-strand repairs. The gliding resistance of the TSOL knot was significantly decreased compared with that of the square knot in both 2-strand and 4-stand repairs (p < 0.05). With regard to failure mode, the TSOL knot was less likely to fail due to knot unravelling. Conclusions: In this in vitro biomechanical study involving the use of turkey flexor tendons to compare gliding resistance and repair strength characteristics for knot-inside 2 and 4-strand repairs, the TSOL knot was associated with decreased repaired tendon gliding resistance, regardless of the number of strands used. Although the TSOL knot also increased the repair strength, the difference was only significant when 2-strand repairs were used. The results of our study support the use of the TSOL knot in the clinical setting of flexor tendon repair using 2 or 4-strand, knot-inside methods. Clinical Relevance: In surgical repair of flexor tendons, there is substantial interest in maximizing strength while minimizing friction. This study shows the potential utility of the TSOL knot to increase repair strength while decreasing gliding resistance, particularly in 2-strand repairs.
The Effect of Gelatin Molecular Weight on Tendon Lubrication Utilizing an Extrasynovialized Turkey Flexor Tendon Model
ABSTRACT Introduction Flexor tendon injuries are common hand injuries among the military population often resulting in functional impairment. Flexor tendon gliding friction has been linked to adhesion formation, especially with the use of extrasynovial grafts. Carbodiimide-derivatized hyaluronic acid with gelatin (cd-HA-gelatin) can reduce gliding friction of the tendon graft; however, the effects of gelatin molecular weight (MW) have not been studied. The turkey model has been shown to better match humans, but extrasynovial tendons are unavailable. The purpose of this study was to (1) manually roughen turkey flexor digitorum profundus (FDP) tendons to simulate extrasynovial tendons and (2) investigate the effects of gelatin MW on tendon friction. Materials and Methods The third digit of (n = 48) turkeys were dissected with the proximal pulley, and FDP tendon and the flexor superficialis tendon were preserved. Digits were randomly assigned into four groups: one saline control and three cd-HA-gelatin-treated groups of varying gelatin MW. Flexor digitorum profundus tendon friction was measured at its original condition, serving as a baseline. Tendons were roughened using a custom rig, and tendon friction was measured again. All four groups received treatment and gliding friction was measured every 100 cycles to a total of 1,000 cycles. Results Tendon friction significantly increased (P < 0.05) after roughening. Friction in the saline control group increased steadily over repeated cycles, whereas friction of all gelatin-treated tendons decreased significantly compared with the saline control group (P < 0.05), maintaining low friction to 1,000 cycles representing human tendons. There was no significant difference found between gelatin-treated groups. Conclusions We have developed a method to roughen synovial FDP tendons to create extrasynovial-like tendons for lubrication material evaluations. Cd-HA-gelatin effectively reduces tendon friction in this model. Our data suggest medium or low MW gelatin may provide a better reduction in friction compared with high MW gelatin.
Characterization of a purified exosome product and its effects on canine flexor tenocyte biology
AbstractFlexor tendon injuries and tendinopathy are very common but remain challenging in clinical treatment. Exosomes‐based cell‐free therapy appears to be a promising strategy for tendon healing, while limited studies have evaluated its impacts on tenocyte biology. The objective of this study was to characterize a novel purified exosome product (PEP) derived from plasma, as well as to explore its cellular effects on canine tenocyte biology. The transmission electron microscope revealed that exosomes of PEP present cup‐shaped structures with the diameters ranged from 80 to 141 nm, and the NanoSight report presented that their size mainly concentrated around 100 nm. The enzyme‐linked immunosorbent assay kits analysis showed that PEP was positive for CD63 and AChE expression, and the cellular uptake of exosomes internalized into tenocyte cytoplasm was observed. The cell growth assays displayed that tenocyte proliferation ability was enhanced by PEP solution in a dose‐dependent manner. Tenogenic phenotype was preserved as is evident by that tendon‐related genes expression (SCX, COL1A, COL3A1, TNMD, DCN, and MKX) were expressed insistently in a high level, while tenocytes were treated with 5% PEP solution. Furthermore, migration capability was maintained and total collagen deposition was increased. More interesting, dexamethasone‐induced cellular apoptosis was attenuated during the incubation of tenocytes with a 5% PEP solution. These findings will provide the basic understandings about the PEP, and support the potential use of this biological strategy for tendon healing.
Biological analysis of flexor tendon repair-failure stump tissue: a potential recycling of tissue for tendon regeneration
Objectives Re-rupture is common after primary flexor tendon repair. Characterization of the biological changes in the ruptured tendon stumps would be helpful, not only to understand the biological responses to the failed tendon repair, but also to investigate if the tendon stumps could be used as a recycling biomaterial for tendon regeneration in the secondary grafting surgery. Methods A canine flexor tendon repair and failure model was used. Following six weeks of repair failure, the tendon stumps were analyzed and characterized as isolated tendon-derived stem cells (TDSCs). Results Failed-repair stump tissue showed cellular accumulation of crumpled and disoriented collagen fibres. Compared with normal tendon, stump tissue had significantly higher gene expression of collagens I and III, matrix metalloproteinases (MMPs), vascular endothelial growth factor (VEGF), platelet-derived growth factor (PDGF), and insulin-like growth factor (IGF). The stump TDSCs presented both mesenchymal stem and haematopoietic cell markers with significantly increased expression of CD34, CD44, and CD90 markers. Stump TDSCs exhibited similar migration but a lower proliferation rate, as well as similar osteogenic differentiation but a lower chondrogenic/adipogenic differentiation capability, compared with normal TDSCs. Stump TDSCs also showed increasing levels of SRY-box 2 (Sox2), octamer-binding transcription factor 4 (Oct4), tenomodulin (TNMD), and scleraxis (Scx) protein and gene expression. Conclusion We found that a failed repair stump had increased cellularity that preserved both mesenchymal and haematopoietic stem cell characteristics, with higher collagen synthesis, MMP, and growth factor gene expression. This study provides evidence that tendon stump tissue has regenerative potential. Cite this article: C-C. Lu, T. Zhang, R. L. Reisdorf, P. C. Amadio, K-N. An, S. L. Moran, A. Gingery, C. Zhao. Biological analysis of flexor tendon repair-failure stump tissue: A potential recycling of tissue for tendon regeneration. Bone Joint Res 2019;8:232–245. DOI: 10.1302/2046-3758.86.BJR-2018-0239.R1.
Revitalized and synovialized allograft for intrasynovial flexor tendon reconstruction in an in vivo canine model
Background: Flexor tendon injury is common, and tendon reconstruction is indicated clinically if the primary repair fails or cannot be performed immediately after tendon injury. The purpose of the current study was to compare clinically standard extrasynovial autologous graft (EAG) tendon and intrasynovial allogeneic graft (IAG) that had both undergone biolubricant surface modification in a canine in vivo model. Methods: Twenty-four flexor digitorum profundus (FDP) tendons from the second and fifth digits of 12 dogs were used for this study. In the first phase, a model of failed FDP tendon repair was created. After 6 weeks, the ruptured FDP tendons with a scarred digit were reconstructed with the use of either EAG or IAG tendons treated with carbodiimide-derivatized hyaluronic acid and lubricin. At 12 weeks after tendon reconstruction, the digits were harvested for functional, biomechanical, and histologic evaluations. Results: The tendon failure model was a clinically relevant and reproducible model for tendon reconstruction. The IAG group demonstrated improved digit function with decreased adhesion formation, lower digit work of flexion, and improved graft gliding ability compared with the EAG group. However, the IAG group had decreased healing at the distal tendon-bone junction. Our histologic findings verified the biomechanical evaluations and, further, showed that cellular repopulation of allograft at 12 weeks after reconstruction is still challenging. Conclusions: FDP tendon reconstruction using IAG with surface modification has some beneficial effects for reducing adhesions but demonstrated inferior healing at the distal tendon-bone junction compared with EAG. These mixed results indicate that vitalization and turnover acceleration are crucial to reducing failure of reconstruction with allograft. Clinical Relevance: Flexor tendon reconstruction is a common surgical procedure. However, postoperative adhesion formation may lead to unsatisfactory clinical outcomes. In this study, we developed a potential flexor tendon allograft using chemical and tissue-engineering approaches. This technology could improve function following tendon reconstruction.
Effects of lubricant and autologous bone marrow stromal cell augmentation on immobilized flexor tendon repairs