Back to Authors

Grahn, Peter J.

https://orcid.org/0000-0002-2976-814X

Mayo Clinic

Mayo Clinic

Citations 18

The Translesional Spinal Network and Its Reorganization after Spinal Cord Injury
Krůpa, Petr , Siddiqui, Ahad M. , Grahn, Peter J. , Islam, Riazul, Chen, Bingkun K. , Madigan, Nicolas N. , Windebank, Anthony J. , Lavrov, Igor , Lavrov, Igor A, Lavrov, Igor

The Neuroscientist | October 22, 2020 | Volume: 28 | Issue: 2 | Pages: 163-179

10.1177/1073858420966276 Get It

Evidence from preclinical and clinical research suggest that neuromodulation technologies can facilitate the sublesional spinal networks, isolated from supraspinal commands after spinal cord injury (SCI), by reestablishing the levels of excitability and enabling descending motor signals via residual connections. Herein, we evaluate available evidence that sublesional and supralesional spinal circuits could form a translesional spinal network after SCI. We further discuss evidence of translesional network reorganization after SCI in the presence of sensory inputs during motor training. In this review, we evaluate potential mechanisms that underlie translesional circuitry reorganization during neuromodulation and rehabilitation in order to enable motor functions after SCI. We discuss the potential of neuromodulation technologies to engage various components that comprise the translesional network, their functional recovery after SCI, and the implications of the concept of translesional network in development of future neuromodulation, rehabilitation, and neuroprosthetics technologies.
Impact of long-term epidural electrical stimulation enabled task-specific training on secondary conditions of chronic paraplegia in two humans
Veith, Daniel D. , Linde, Margaux , Gill, Megan L., Calvert, Jonathan S. , Grahn, Peter J. , Garlanger, Kristin, Husmann, Douglas A. , Lavrov, Igor , Sayenko, Dimitry G. , Strommen, Jeffrey A., Lee, Kendall, Zhao, Kristin D. , Beck, Lisa, Veith, Daniel, Gill, Megan, Calvert, Jonathan, Grahn, Peter, Husmann, Douglas , Strommen, Jeffrey, Zhao, Kristin, Lavrov, Igor , Trentadue, Taylor P , Sayenko, Dimitry G , Beck, Lisa, Lee, Kendall H.

The Journal of Spinal Cord Medicine | March 23, 2020 | Volume: 44 | Issue: 5 | Pages: 800-805

10.1080/10790268.2020.1739894 Get It

Preferential activation of spinal sensorimotor networks via lateralized transcutaneous spinal stimulation in neurologically intact humans
Calvert, Jonathan S. , Manson, Gerome A. , Grahn, Peter J. , Sayenko, Dimitry G. , Sayenko, Dimitry G

Journal of Neurophysiology | September 25, 2019 | Volume: 122 | Issue: 5 | Pages: 2111-2118

10.1152/jn.00454.2019 Get It

Transcutaneous spinal stimulation (TSS), a noninvasive technique to modulate sensorimotor circuitry within the spinal cord, has been shown to enable a wide range of functions that were thought to be permanently impaired in humans with spinal cord injury. However, the extent to which TSS can be used to target specific mediolateral spinal cord circuitry remains undefined. We tested the hypothesis that TSS applied unilaterally to the skin ~2 cm lateral to the midline of the lumbosacral spine selectively activates ipsilateral spinal sensorimotor circuitry, resulting in ipsilateral activation of downstream lower extremity neuromusculature. TSS cathodes and anodes were positioned lateral from the midline of the spine in 15 healthy subjects while supine, and the timing of TSS pulses was synchronized to recordings of lower extremity muscle activity and force. At motor threshold, left and right TSS-evoked muscle activity was significantly higher in the ipsilateral leg compared with contralateral recordings from the same muscles. Similarly, we observed a significant increase in force production in the ipsilateral leg compared with the contralateral leg. Delivery of paired TSS pulses, during which an initial stimulus was applied to one side of the spinal cord and 50 ms later a second stimulus was applied to the contralateral side, revealed that ipsilateral leg muscle responses decreased following the initial stimulus, whereas contralateral muscle responses did not decrease, indicating side-specific activation of lateral spinal sensorimotor circuitry. Our results indicate TSS can selectively engage ipsilateral neuromusculature via lumbosacral sensorimotor networks responsible for lower extremity function in healthy humans. NEW & NOTEWORTHY We demonstrate the selectivity of transcutaneous spinal stimulation (TSS), which has been shown to enable function in humans with chronic paralysis. Specifically, we demonstrate that TSS applied to locations lateral to the spinal cord can selectively activate ipsilateral spinal sensorimotor networks. We quantified lumbosacral spinal network activity by recording lower extremity muscle electromyography and force. Our results suggest lumbosacral TSS engages side-specific spinal sensorimotor networks associated with ipsilateral lower extremity function in humans.
Electrophysiological Guidance of Epidural Electrode Array Implantation over the Human Lumbosacral Spinal Cord to Enable Motor Function after Chronic Paralysis
Calvert, Jonathan S. , Grahn, Peter J. , Strommen, Jeffrey A., Lavrov, Igor , Gill, Megan L., Linde, Margaux B. , Straaten, Meegan G. Van , Veith, Daniel D. , Lopez, Cesar , Sayenko, Dimitry G. , Gerasimenko, Yury , Edgerton, V. Reggie , Zhao, Kristin D. , Lee, Kendall H. , Lavrov, Igor A, Brown, Desmond A., Van Straaten, Meegan G, Lavrov, Igor , Trentadue, Taylor P , Beck, Lisa A., Brown, Desmond , Sayenko, Dimitry G

Journal of Neurotrauma | November 15, 2018 | Volume: 36 | Issue: 9 | Pages: 1451-1460

10.1089/neu.2018.5921 Get It

Epidural electrical stimulation (EES) of the spinal cord has been shown to restore function after spinal cord injury (SCI). Characterization of EES-evoked motor responses has provided a basic understanding of spinal sensorimotor network activity related to EES-enabled motor activity of the lower extremities. However, the use of EES-evoked motor responses to guide EES system implantation over the spinal cord and their relation to post-operative EES-enabled function in humans with chronic paralysis attributed to SCI has yet to be described. Herein, we describe the surgical and intraoperative electrophysiological approach used, followed by initial EES-enabled results observed in 2 human subjects with motor complete paralysis who were enrolled in a clinical trial investigating the use of EES to enable motor functions after SCI. The 16-contact electrode array was initially positioned under fluoroscopic guidance. Then, EES-evoked motor responses were recorded from select leg muscles and displayed in real time to determine electrode array proximity to spinal cord regions associated with motor activity of the lower extremities. Acceptable array positioning was determined based on achievement of selective proximal or distal leg muscle activity, as well as bilateral muscle activation. Motor response latencies were not significantly different between intraoperative recordings and post-operative recordings, indicating that array positioning remained stable. Additionally, EES enabled intentional control of step-like activity in both subjects within the first 5 days of testing. These results suggest that the use of EES-evoked motor responses may guide intraoperative positioning of epidural electrodes to target spinal cord circuitry to enable motor functions after SCI.
Chapter 16 Functional Electrical Stimulation for the Treatment of Spinal Cord Injury
Grahn, Peter J. , Ruiz, Aldo A. Mendez, Ruiz, Aldo A. Mendez, Hachmann, Jan T. , Luján, J. Luis

Deep Brain Stimulation | December 2, 2016 | Volume: No volume available | Issue: No issue available | Pages: 283-310

10.1201/9781315364759-17 Get It

MRI-Guided Stereotactic System for Delivery of Intraspinal Microstimulation
Grahn, Peter J. , Goerss, Stephan J., Mallory, Grant W., Kall, Bruce A., Mendez, Aldo A. , Trevathan, James K. , Felmlee, Joel P. , Bennet, Kevin E. , Lee, Kendall H. , Luján, J. Luis , Trevathan, James K

Spine | December 16, 2015 | Volume: 41 | Issue: 13 | Pages: E806-E813

10.1097/brs.0000000000001397 Get It

Study Design. Laboratory/animal-based proof of principle study. Objective. To validate the accuracy of a magnetic resonance imaging (MRI)-guided stereotactic system for intraspinal electrode targeting and demonstrate the feasibility of such a system for controlling implantation of intraspinal electrodes. Summary of Background Data. Intraspinal microstimulation (ISMS) is an emerging preclinical therapy, which has shown promise for the restoration of motor function following spinal cord injury. However, targeting inaccuracy associated with existing electrode implantation techniques remains a major barrier preventing clinical translation of ISMS. Methods. System accuracy was evaluated using a test phantom comprised of nine target locations. Targeting accuracy was determined by calculating the root mean square error between MRI-generated coordinates and actual frame coordinates required to reach the target positions. System performance was further validated in an anesthetized pig model by performing MRI-guided intraspinal electrode implantation and stimulation followed by computed tomography of electrode location. Finally, system compatibility with a commercially available microelectrode array was demonstrated by implanting the array and applying a selection of stimulation amplitudes that evoked hind limb responses. Results. The root mean square error between actual frame coordinates and software coordinates, both acquired using the test phantom, was 1.09 ± 0.20 mm. Postoperative computed tomography in the anesthetized pig confirmed spatially accurate electrode placement relative to preoperative MRI. Additionally, MRI-guided delivery of a microwire electrode followed by ISMS evoked repeatable electromyography responses in the biceps femoris muscle. Finally, delivery of a microelectrode array produced repeatable and graded hind limb evoked movements. Conclusion. We present a novel frame-based stereotactic system for targeting and delivery of intraspinal instrumentation. This system utilizes MRI guidance to account for variations in anatomy between subjects, thereby improving upon existing ISMS electrode implantation techniques. Level of Evidence: N/A
Positively Charged Oligo[Poly(Ethylene Glycol) Fumarate] Scaffold Implantation Results in a Permissive Lesion Environment after Spinal Cord Injury in Rat
Hakim, Jeffrey S. , Rad, Melika Esmaeili, Grahn, Peter J. , Chen, Bingkun K. , Schmeichel, Ann M., Isaq, Nasro A., Dadsetan, Mahrokh, Yaszemski, Michael J. , Windebank, Anthony J. , Esmaeili Rad, Melika, Knight, Andrew M, Knight, Andrew M.

Tissue Engineering Part A | April 19, 2015 | Volume: 21 | Issue: 13-14 | Pages: 2099-2114

10.1089/ten.tea.2015.0019 Get It

Wireless control of intraspinal microstimulation in a rodent model of paralysis
Grahn, Peter J. , Lee, Kendall H. , Kasasbeh, Aimen, Mallory, Grant W., Hachmann, Jan T. , Dube, John R., Kimble, Christopher J., Lobel, Darlene A., Bieber, Allan J., Jeong, Ju Ho , Bennet, Kevin E. , Bieber, Allan, Luján, J. Luis

Journal of Neurosurgery | December 5, 2014 | Volume: 123 | Issue: 1 | Pages: 232-242

10.3171/2014.10.jns132370 Get It

OBJECT Despite a promising outlook, existing intraspinal microstimulation (ISMS) techniques for restoring functional motor control after spinal cord injury are not yet suitable for use outside a controlled laboratory environment. Thus, successful application of ISMS therapy in humans will require the use of versatile chronic neurostimulation systems. The objective of this study was to establish proof of principle for wireless control of ISMS to evoke controlled motor function in a rodent model of complete spinal cord injury. METHODS The lumbar spinal cord in each of 17 fully anesthetized Sprague-Dawley rats was stimulated via ISMS electrodes to evoke hindlimb function. Nine subjects underwent complete surgical transection of the spinal cord at the T-4 level 7 days before stimulation. Targeting for both groups (spinalized and control) was performed under visual inspection via dorsal spinal cord landmarks such as the dorsal root entry zone and the dorsal median fissure. Teflon-insulated stimulating platinum-iridium microwire electrodes (50 μm in diameter, with a 30- to 60-μm exposed tip) were implanted within the ventral gray matter to an approximate depth of 1.8 mm. Electrode implantation was performed using a free-hand delivery technique (n = 12) or a Kopf spinal frame system (n = 5) to compare the efficacy of these 2 commonly used targeting techniques. Stimulation was controlled remotely using a wireless neurostimulation control system. Hindlimb movements evoked by stimulation were tracked via kinematic markers placed on the hips, knees, ankles, and paws. Postmortem fixation and staining of the spinal cord tissue were conducted to determine the final positions of the stimulating electrodes within the spinal cord tissue. RESULTS The results show that wireless ISMS was capable of evoking controlled and sustained activation of ankle, knee, and hip muscles in 90% of the spinalized rats (n = 9) and 100% of the healthy control rats (n = 8). No functional differences between movements evoked by either of the 2 targeting techniques were revealed. However, frame-based targeting required fewer electrode penetrations to evoke target movements. CONCLUSIONS Clinical restoration of functional movement via ISMS remains a distant goal. However, the technology presented herein represents the first step toward restoring functional independence for individuals with chronic spinal cord injury.