Back to Authors

Deshmukh, Abhishek

https://orcid.org/0000-0002-9560-1102

Mayo Clinic

Mayo Clinic

Citations 260

Abstract 18514: Outcomes of Different Mechanical Circulatory Support (MCS) Devices and Transcatheter Aortic Valve Replacement (TAVR): A National Cross-sectional US Experience
Savani, Chirag, Singh, Vikas , Sonani, Rajesh, Arora, Shilpkumar , Thakkar, Badal, Patel, Nilay, Patel, Nileshkumar , Patel, Achint , Patel, Aashay, Dave, Abhishek , Chothani, Ankit , Deshmukh, Abhishek , Badheka, Apurva O., Patel, Samir , Lahewala, Sopan , Panaich, Sidakpal , Bhatt, Parth , Dave, Abhishek, Jhamnani, Sunny

Circulation | March 19, 2022 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.18514 Get It

Introduction: The data regarding use of different Mechanical Circulatory Support (MCS) devices in TAVR is limited. The present study was performed to analyze the complications and outcomes of different MCS in TAVR. Methods: The subjects under study were obtained from Nationwide Inpatient Sample (NIS) for the years 2011-12 using ICD-9-CM procedure codes for TAVR and MCS. The use of MCS was divided into Intra-aortic balloon pump (IABP), percutaneous ventricular assist devices (PVADs) including Impella and TandemHeart, Extracorporeal membrane oxygenation (ECMO) and percutaneous cardiopulmonary support and cardiopulmonary bypass (CBP) using ICD-9-CM codes. The incidence of in-hospital mortality and occurrence of procedure related complications were analyzed. Results: Out of total 1794 TAVR procedures, MCS was utilized in 190 (10.6%) procedures. CBP was the most commonly utilized 136 (71.6%) followed by IABP 36 (18.9%), ECMO 14 (7.4%) and 4 (2.1%). In-hospital mortality was highest with use of IABP (36.6%), followed by ECMO (14.3%), CBP (9.6%) and PVAD (0%) with p-value <0.01. The incidence of complications was similar in IABP and PVAD (100% each) followed by ECMO (85.7%) and CBP (59.4%) with p-value <0.01. Conclusion: Being retrospective in design, the present study has no information regarding indications and individual patient related variables in which each of the MCS devices used. Overall, CBP was observed as the most extensive used MCS modality with less mortality (9.6%) and least complications (59.4%).
Abstract 18193: Transcatheter Aortic Valve Replacement versus Surgical Aortic Valve Replacement in Patients With Cirrhosis: A Propensity Score Matched Analysis
Thakkar, Badal, Patel, Aashay, Bhimani, Ronak , Patel, Nileshkumar , Savani, Chirag, Patel, Achint , Sonani, Rajesh, Arora, Shilpkumar , Patel, Nilay , Dave, Abhishek , Chothani, Ankit , Singh, Vikas , Deshmukh, Abhishek , Badheka, Apurva O., Bhatt, Parth , Patel, Samir , Solanki, Shantanu , Lahewala, Sopan , Dave, Abhishek, Panaich, Sidakpal

Circulation | March 19, 2022 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.18193 Get It

Introduction: Over the past decade, Transcatheter Aortic Valve Replacement (TAVR) has emerged as a therapeutic option for treating severe aortic stenosis in high-risk patients. Patients with liver cirrhosis are at high risk for operative morbidity and mortality when they undergo cardiac surgery. In the present study, in-hospital outcomes are compared in cirrhotic patients undergoing TAVR vs. Surgical Aortic Valve Replacement (SAVR). Methods: The study population was derived from the National Inpatient Sample (NIS) for the years 2011 and 2012 using the International Classification of Diseases, 9th Revision, Clinical Modification (ICD-9-CM) procedure codes 35.21 and 35.22 for SAVR, and 35.05 and 35.06 for TAVR. Patients<50 years of age and those with concomitantly other valvular procedures were excluded. ICD-9-CM diagnosis codes were used to identify patients with liver cirrhosis including those with other manifestations of cirrhosis such as portal hypertension and esophageal varices. Using propensity score matching, two matched cohorts were derived in which the outcomes were compared using chi-square test, fisher’s exact test, and student’s t-test. Results: There were 30 cirrhotic patients in the SAVR and TAVR group each after propensity score matching. Compared to the TAVR group, the patients in the SAVR group had higher mean cost of hospitalization ($79,263 vs. $63,913, p=0.12), mean post-procedural length of stay (14.3 days vs. 6.2 days, p<0.01), any complications rate (80.0% vs. 60.0%, p=0.09), rate of transfusion of blood or blood products (56.7% vs. 30.0%, p=0.037) and liver complications rate (20.0% vs. 10.0%, p=0.4). The in-hospital mortality rate was same in both the groups (6.7%). Conclusions: In high-risk cirrhotic patients, TAVR is a viable option for aortic valve replacement compared to SAVR.
Abstract 16562: Cardiac Device Implantation Post TAVR: Mortality and Rates of Pacemaker Dependency
Padmanabhan, Deepak , Eleid, Mackram F. , Deshmukh, Abhishek , Cha, Yong-Mei M, Asirvatham, Samuel, Friedman, Paul A. , Greason, Kevin L. , Gulati, Rajiv , Scott, Christopher G. , McLeod, Christopher J. , Cha, Yong-Mei M, Noseworthy, Peter A.

Circulation | March 19, 2022 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.16562 Get It

Background: Transcatheter aortic valve replacement (TAVR) is often complicated by AV block requiring pacing, but whether patients recover AV conduction and whether the need for pacing affects outcomes is unknown. Methods: We retrospectively studied 534 patients who underwent TAVR at Mayo Clinic in Rochester, Minnesota between November 2008 and January 2015. Of these, 115 patients had implantable cardiac devices. Data was collected from subsequent device follow-ups to determine pacemaker dependency and percentage pacing. Results: 44 patients (8.2%) had devices implanted in the immediate post procedural period. The most common indications for implantation were high grade AV block (18 patients) and complete heart block (14 patients). 17/44 (38.6%) patients were pacemaker-dependent at implant and only 4 of these patients were no longer pacemaker-dependent during subsequent followup. The indication for pacing among these four patients was high grade atrio-ventricular block (2 patients), asystole (1 patient) and complete heart block (1). Among non-pacemaker-dependent patients, no significant change in the ventricular pacing percentages was noted over time. Survival was similar between patients who required device implantation post TAVR and those who did not after adjustment for age and gender (HR 0.73 [0.39-1.36], p=ns; figure) Conclusion: Patients requiring pacing after TAVR are often pacemaker-dependent at the time of implant. It is uncommon for patients who are dependent at the time of implant to regain AV conduction, but the need for cardiac pacing is not associated with increased mortality.
A real‐world experience of atrioventricular synchronous pacing with leadless ventricular pacemakers
Kowlgi, Gurukripa N. , Tseng, Andrew S. , Tempel, Nathan D., Henrich, Mark, Venkatachalam, Kalpathi L., Scott, Luis R. , Shen, Win‐Kuang , Deshmukh, Abhishek , Madhavan, Malini , Lee, Hon‐Chi, Asirvatham, Samuel J. , Friedman, Paul A. , Cha, Yong‐Mei , Mulpuru, Siva K. , Henrich, Mark J, Deshmukh, Abhishek J , Tseng, A S , Asirvatham, Samuel J , Kowlgi, Narayan G

Journal of Cardiovascular Electrophysiology | March 2, 2022 | Volume: 33 | Issue: 5 | Pages: 982-993

10.1111/jce.15430 Get It

AbstractAimsThe MicraTM transcatheter pacing system (TPS) (Medtronic) is the only leadless pacemaker that promotes atrioventricular (AV) synchrony via accelerometer‐based atrial sensing. Data regarding the real‐world experience with this novel system are scarce. We sought to characterize patients undergoing MicraTM‐AV implants, describe percentage AV synchrony achieved, and analyze the causes for suboptimal AV synchrony.MethodsIn this retrospective cohort study, electronic medical records from 56 consecutive patients undergoing MicraTM‐AV implants at the Mayo Clinic sites in Minnesota, Florida, and Arizona with a minimum follow‐up of 3 months were reviewed. Demographic data, comorbidities, echocardiographic data, and clinical outcomes were compared among patients with and without atrial synchronous ventricular pacing (AsVP) ≥ 70%.ResultsSixty‐five percent of patients achieved AsVP ≥ 70%. Patients with adequate AsVP had smaller body mass indices, a lower proportion of congestive heart failure, and prior cardiac surgery. Echocardiographic parameters and procedural characteristics were similar across the two groups. Active device troubleshooting was associated with higher AsVP. The likely reasons for low AsVP were small A4‐wave amplitude, high ventricular pacing burden, and inadequate device reprogramming. Importantly, in patients with low AsVP, subjective clinical worsening was not noted during follow‐up.ConclusionWith the increasing popularity of leadless pacemakers, it is paramount for device implanting teams to be familiar with common predictors of AV synchrony and troubleshooting with MicraTM‐AV devices.
Heart Watch Study: protocol for a pragmatic randomised controlled trial
Dhruva, Sanket S. , Shah, Nilay D. , Vemulapalli, Sreekanth , Deshmukh, Abhishek , Gamble, Ginger , Hummel, James P. , Piccini, Jonathan P. , Akar, Joseph G. , Ervin, Keondae, Arges, Kristine, Emanuel, Lindsay, Hu, Tiffany , Bartlett, Victoria , Gamble, Ginger M , Piccini, Jonathan P , Beatty, Alexis L. , Freeman, James V. , Noseworthy, Peter A. , Hu, Tiffany, Ross, Joseph S.

BMJ Open | December 30, 2021 | Volume: 11 | Issue: 12 | Pages: e054550

10.1136/bmjopen-2021-054550 Get It

Introduction Personal digital devices that provide health information, such as the Apple Watch, have developed an increasing array of cardiopulmonary tracking features which have received regulatory clearance and are directly marketed to consumers. Despite their widespread and increasing use, data about the impact of personal digital device use on patient-reported outcomes and healthcare utilisation are sparse. Among a population of patients with atrial fibrillation and/or atrial flutter undergoing cardioversion, our primary aim is to determine the impact of the heart rate measurement, irregular rhythm notification, and ECG features of the Apple Watch on quality of life and healthcare utilisation. Methods and analysis We are conducting a prospective, open-label multicentre pragmatic randomised clinical trial, leveraging a unique patient-centred health data sharing platform for enrolment and follow-up. A total of 150 patients undergoing cardioversion for atrial fibrillation or atrial flutter will be randomised 1:1 to receive the Apple Watch Series 6 or Withings Move at the time of cardioversion. The primary outcome is the difference in the Atrial Fibrillation Effect on QualiTy-of-life global score at 6 months postcardioversion. Secondary outcomes include inpatient and outpatient healthcare utilisation. Additional secondary outcomes include a comparison of the Apple Watch ECG and pulse oximeter features with gold-standard data obtained in routine clinical care settings. Ethics and dissemination The Institutional Review Boards at Yale University, Mayo Clinic, and Duke University Health System have approved the trial protocol. This trial will provide important data to policymakers, clinicians and patients about the impact of the heart rate, irregular rhythm notification, and ECG features of widely used personal digital devices on patient quality of life and healthcare utilisation. Findings will be disseminated to study participants, at professional society meetings and in peer-reviewed journals. Trial registration number NCT04468321
Gradual prolongation of PR interval followed by a pause. What is the mechanism?
Ghosh, Anindya , Raja, Deep Chandh , Deshmukh, Abhishek , Pandurangi, Ulhas M. , Raja, Deep C

Journal of Cardiovascular Electrophysiology | December 25, 2021 | Volume: 33 | Issue: 3 | Pages: 540-543

10.1111/jce.15338 Get It

Characteristics and outcomes of ventricular tachycardia and premature ventricular contractions ablation in patients with prior mitral valve surgery
Khalil, Fouad , Madhavan, Malini , Ahmad, Ali , Mulpuru, Siva K. , Siontis, Konstantinos C. , Deshmukh, Abhishek , Cha, Yong‐Mei , Friedman, Paul A. , Munger, Thomas M. , Asirvatham, Samuel J. , Killu, Ammar M. , Madhavan, Malini , Kapa, Suraj , Mulpuru, Siva K , Siontis, Konstantinos C , Deshmukh, Abhishek J , Friedman, Paul A , Munger, Thomas, Asirvatham, Samuel J , Killu, Ammar M , Khalil, Fouad , Toya, Takumi , Badawy, Mohamed, Kapa, Suraj , DeSimone, Christopher V.

Journal of Cardiovascular Electrophysiology | December 15, 2021 | Volume: 33 | Issue: 2 | Pages: 274-283

10.1111/jce.15331 Get It

AbstractBackgroundData regarding ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation following mitral valve surgery (MVS) is limited. Catheter ablation (CA) can be challenging given perivalvular substrate in the setting of mitral annuloplasty or prosthetic valves.ObjectiveTo investigate the characteristics, safety, and outcomes of radiofrequency CA in patients with prior MVS and ventricular arrhythmias (VA).MethodsWe identified consecutive patients with prior MVS who underwent CA for VT or PVC between January 2013 and December 2018. We investigated the mechanism of arrhythmia, ablation approach, peri‐operative complications, and outcomes.ResultsIn our cohort, 31 patients (77% men, mean age 62.3 ± 10.8 years, left ventricular ejection fraction 39.2 ± 13.9%) with prior MVS underwent CA (16 VT; 15 PVC). Access to the left ventricle was via transseptal approach in 17 patients, and a retrograde aortic approach was used in 13 patients. A combined transseptal and retrograde aortic approach was used in one patient, and a percutaneous epicardial approach was combined with trans‐septal approach in one patient. Heterogenous scar regions were present in 94% of VT patients and scar‐related reentry was the dominant mechanism of VT. Forty‐seven percent of PVC patients had abnormal substrate at the site targeted for ablation. Clinical VA substrates involved the peri‐mitral area in six patients with VT and five patients with PVC ablation. No procedure‐related complications were reported. The overall recurrence‐free rate at 1‐year was 72.2%; 67% in the VT group and 78% in the PVC group. No arrhythmia‐related death was documented on long‐term follow‐up.ConclusionCA of VAs can be performed safely and effectively in patients with MVS.
Catheter ablation versus medical therapy for atrial fibrillation: Penny‐wise Pound‐foolish
Kowlgi, Gurukripa N. , Deshmukh, Abhishek , Deshmukh, Abhishek J , Kowlgi, Narayan G

Journal of Cardiovascular Electrophysiology | December 12, 2021 | Volume: 33 | Issue: 2 | Pages: 176-177

10.1111/jce.15316 Get It

AbstractCatheter ablation for atrial fibrillation has emerged as a mainstay for the management of atrial fibrillation. It has been shown to be clinically effective and cost‐effective in multiple trials.
Risk of left atrial appendage thrombus and stroke in patients with atrial fibrillation and mitral regurgitation
Melduni, Rowlens M. , Nkomo, Vuyisile T. , Deshmukh, Abhishek , Padang, Ratnasari , Greene, Eddie L., Oh, Jae K. , Lee, Hon-Chi, Melduni, Rowlens , Padang, Ratnasari , Nkomo, Vuyisile T , Wysokiński, Waldemar E. , Gersh, Bernard J.

Heart | December 10, 2021 | Volume: 108 | Issue: 1 | Pages: 29-36

10.1136/heartjnl-2020-317659 Get It

Objective To investigate the association of mitral regurgitation (MR) on thromboembolic risk of patients with non-valvular atrial fibrillation (NVAF) undergoing transoesophageal echocardiography (TEE)-guided cardioversion. Methods Data for consecutive patients who underwent TEE-guided cardioversion for NVAF between 2000 and 2012 were analysed. MR severity was assessed by Doppler echocardiography and classified as ≤mild, moderate or severe. Left atrial appendage emptying velocities were averaged for five consecutive cycles. Multivariable regression models were used to identify independent predictors of left atrial appendage thrombus (LAAT) and stroke. Results 2950 patients (age, 69.3±12.2 years, 67% men) were analysed. 2173 (73.7%) had ≤mild MR; 631 (21.4%), moderate MR; and 146 (4.9%), severe MR. Patients with moderate (age, 72.4±10.7 years) and severe (age, 72.8±12.1 years) MR were older than those with ≤mild MR (age, 68.2±12.5 years). The prevalence of LAAT was 1.5% (n=43). CHA 2 DS 2 -VASc scores (≤mild MR, 3.0±1.6; moderate MR, 3.5±1.5; severe MR, 3.9±1.5; p<0.001) and heart failure frequency (≤mild MR, 38.4%; moderate MR, 48.0%; severe MR, 69.2%; p<0.001) were increasingly higher with greater MR severity. Multivariable logistic regression analysis showed no association of moderate MR (OR 0.77, 95% CI 0.38 to 1.56) or severe MR (OR 0.55, 95% CI 0.21 to 1.49) with LAAT. During a mean follow-up of 7.3±5.1 years (median 7.5, IQR, 2.7–10.9), 216 patients had an ischaemic stroke. Adjusted Cox regression analysis showed no significant association of moderate MR (HR 1.22, 95% CI 0.88 to 1.68) or severe MR (HR 0.73, 95% CI 0.31 to 1.46) with stroke. Conclusions Among patients with NVAF, the presence or severity of MR was not associated with a decreased risk of LAAT or stroke.
Gradual prolongation of PR interval followed by a pause. What's the mechanism?
Ghosh, Anindya , Raja, Deep Chandh , Deshmukh, Abhishek , Raja, Deep C , Pandurangi, Ulhas M.

No container title available | December 5, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.163875594.48423668/v1 Get It