Abstract Aims Syncope remains a diagnostic challenge despite advancements in testing and treatment. Cardiac syncope is an independent predictor of mortality and can be difficult to distinguish from other causes of transient loss of consciousness (TLOC). This paper explores whether artificial intelligence (AI) can improve the evaluation and management of patients with syncope. Methods and results We conducted a literature review and incorporated the opinions of experts in the fields of syncope and AI. The cause of TLOC is often unclear, hospitalization criteria are ambiguous, diagnostic tests are frequently non-informative, and assessments are costly. Patients are left with unanswered questions and limited guidance. Artificial intelligence (AI) has the potential to optimize syncope evaluation by processing large data sets, detecting imperceptible patterns, and assisting clinicians. However, AI has limitations, including errors, lack of human empathy, and uncertain clinical utility. Liability issues further complicate its integration. We present three viewpoints: (i) AI is crucial for advancing syncope management; (ii) AI can enhance the patient experience; and (iii) AI in syncope care is inevitable. Conclusion Artificial intelligence may improve syncope diagnosis and management, particularly through machine learning–based test interpretation and wearable device data. However, it has yet to surpass human clinical judgment in complex decision-making. Current challenges include gaps in understanding syncope mechanisms, AI interpretability, generalizability, and clinical integration. Standardized diagnostic approaches, real-world validation, and curated data sets are essential for progress. Artificial intelligence may enhance efficiency and communication but raises concerns regarding confidentiality, bias, inequities, and legal implications.
Cardioneuroablation for the treatment of reflex syncope and functional bradyarrhythmias: A Scientific Statement of the European Heart Rhythm Association (EHRA) of the ESC, the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS) and th
Abstract Cardioneuroablation has emerged as a potential alternative to cardiac pacing in selected cases with vasovagal reflex syncope, extrinsic vagally induced sinus bradycardia-arrest or atrioventricular block. The technique was first introduced decades ago, and its use has risen over the past decade. However, as with any intervention, proper patient selection and technique are a prerequisite for a safe and effective use of cardioneuroablation therapy. This document aims to review and interpret available scientific evidence and provide a summary position on the topic.
Monitoring and diagnosis of intermittent arrhythmias: evidence-based guidance and role of novel monitoring strategies
Abstract Technological advances have made diagnosis of heart rhythm disturbances much easier, with a wide variety of options, including single-lead portable devices, smartphones/watches to sophisticated implantable cardiac monitors, allowing accurate data to be collected over different time periods depending on symptoms frequency. This review provides an overview of the novel and existing heart rhythm testing options, including a description of the supporting evidence for their use. A description of each of the tests is provided, along with discussion of their advantages and limitations. This is intended to help clinicians towards choosing the most appropriate test, thus improving diagnostic yield management of patients with suspected arrhythmias.
Clinical applications of heart rhythm monitoring tools in symptomatic patients and for screening in high-risk groups
Abstract Recent technological advances have facilitated and diversified the options available for the diagnosis of cardiac arrhythmias. Ranging from simple resting or exercise electrocardiograms to more sophisticated and expensive smartphones and implantable cardiac monitors. These tests and devices may be used for varying periods of time depending on symptom frequency. The choice of the most appropriate heart rhythm test should be guided by clinical evaluation and optimized following accurate characterization of underlying symptoms, ‘red flags’, risk factors, and consideration of cost-effectiveness of the different tests. This review provides evidence-based guidance for assessing suspected arrhythmia in patients who present with symptoms or in the context of screening, such as atrial fibrillation or advanced conduction disturbances following transcatheter aortic valve implantation in high-risk groups. This is intended to help clinicians choose the most appropriate diagnostic tool to facilitate the management of patients with suspected arrhythmias.
Novel cardiac pacemaker-based human model of periodic breathing to develop real-time, pre-emptive technology for carbon dioxide stabilisation
Background Constant flow and concentration CO2 has previously been efficacious in attenuating ventilatory oscillations in periodic breathing (PB) where oscillations in CO2 drive ventilatory oscillations. However, it has the undesirable effect of increasing end-tidal CO2, and ventilation. We tested, in a model of PB, a dynamic CO2 therapy that aims to attenuate pacemaker-induced ventilatory oscillations while minimising CO2 dose. Methods First, pacemakers were manipulated in 12 pacemaker recipients, 6 with heart failure (ejection fraction (EF)=23.7±7.3%) and 6 without heart failure, to experimentally induce PB. Second, we applied a real-time algorithm of pre-emptive dynamic exogenous CO2 administration, and tested different timings. Results We found that cardiac output alternation using pacemakers successfully induced PB. Dynamic CO2 therapy, when delivered coincident with hyperventilation, attenuated 57% of the experimentally induced oscillations in end-tidal CO2: SD/mean 0.06±0.01 untreated versus 0.04±0.01 with treatment (p<0.0001) and 0.02±0.01 in baseline non-modified breathing. This translated to a 56% reduction in induced ventilatory oscillations: SD/mean 0.19±0.09 untreated versus 0.14±0.06 with treatment (p=0.001) and 0.10±0.03 at baseline. Of note, end-tidal CO2 did not significantly rise when dynamic CO2 was applied to the model (4.84±0.47 vs 4.91± 0.45 kPa, p=0.08). Furthermore, mean ventilation was also not significantly increased by dynamic CO2 compared with untreated (7.8±1.2 vs 8.4±1.2 L/min, p=0.17). Conclusions Cardiac pacemaker manipulation can be used to induce PB experimentally. In this induced PB, delivering CO2 coincident with hyperventilation, ventilatory oscillations can be substantially attenuated without a significant increase in end-tidal CO2 or ventilation. Dynamic CO2 administration might be developed into a clinical treatment for PB. Trial Registration number ISRCTN29344450.
Human CRM1 Augments Production of Infectious Human and Feline Immunodeficiency Viruses from Murine Cells
ABSTRACT Productive replication of human immunodeficiency virus type 1 (HIV-1) occurs efficiently only in humans. The posttranscriptional stages of the HIV-1 life cycle proceed poorly in mouse cells, with a resulting defect in viral assembly and release. Previous work has shown that the presence of human chromosome 2 increases HIV-1 production in mouse cells. Recent studies have shown that human chromosome region maintenance 1 (hCRM1) stimulates Gag release from rodent cells. Here we report that expressions of hCRM1 in murine cells resulted in marked increases in the production of infectious HIV-1 and feline immunodeficiency virus (FIV). HIV-1 production was also increased by hSRp40, and a combination of hCRM1 and hSRp40 resulted in a more-than-additive effect on HIV-1 release. In contrast, the overexpression of mouse CRM1 (mCRM1) minimally affected HIV-1 and FIV production and did not antagonize hCRM1. In the presence of hCRM1 there were large increases in the amounts of released capsid, which paralleled the increases in the infectious titers. Consistent with this finding, the ratios of unspliced to spliced HIV-1 mRNAs in mouse cells expressing hCRM1 and SRp40 became similar to those of human cells. Furthermore, imaging of intron-containing FIV RNA showed that hCRM1 increased RNA export to the cytoplasm.By testing chimeras between mCRM1 and hCRM1 and comparing those sequences to feline CRM1, we mapped the functional domain to HEAT (Huntingtin, elongation factor 3, protein phosphatase 2A, and the yeast kinase TOR1) repeats 4A to 9A and a triple point mutant in repeat 9A, which showed a loss of function. Structural analysis suggested that this region of hCRM1 may serve as a binding site for viral or cellular factors to facilitate lentiviral RNA nuclear export.