Back to Authors

Dipaola, Franca

0000-0002-1557-8935

Mayo Clinic

Internal Medicine, IRCCS Humanitas Research Hospital, Via Manzoni 56, Rozzano, Italy.

Citations 3

The hope and the hype of artificial intelligence for syncope management
Johnston, Samuel L. , Barsotti, Ercole John , Fedorowski, Artur , Ricci, Fabrizio , Heller, Eric G, Sheldon, Robert S. , Sutton, Richard , Shen, Win‐Kuang , Thiruganasambandamoorthy, Venkatesh , Adhaduk, Mehul , Parker, William H. , Aburizik, Arwa , Haselton, Corey R, Cuskey, Alex J, Johansson, Madeleine , Dominic, Paari , Rao, B. Hygriv , Mudireddy, Avinash , Statz, Giselle M., Benditt, David G. , Gatti, Mauro , Menè, Roberto , Shiffer, Dana , Vassilikos, Vassilios , Bakogiannis, Constantinos , Fedorowski, Artur , Ricci, Fabrizio , Sheldon, Robert , Sutton, Richard , Shen, Win-Kuang , Thiruganasambandamoorthy, Venkatesh , Adhaduk, Mehul , Parker, William H , Aburizik, Arwa , Lee, Sangil , Johansson, Madeleine , Macfarlane, Donald , Dominic, Paari , Abe, Haruhiko , Rao, B Hygriv , Mudireddy, Avinash , Sonka, Milan , Sandhu, Roopinder K , Kenny, Rose Anne , Gopinathannair, Rakesh , Benditt, David , Dipaola, Franca , Gatti, Mauro , Giaj Levra, Alessandro , Furlan, Raffaello , Ruwald, Martin H , Vassilikos, Vassilios , Gebska, Milena A , Olshansky, Brian , Cuskey, Alex, Lee, Sangil , Kenny, Rose Anne , Gopinathannair, Rakesh , Dipaola, Franca , Costantino, Giorgio , Furlan, Raffaello , Olshansky, Brian

European Heart Journal - Digital Health | June 25, 2025 | Volume: 6 | Issue: 5 | Pages: 1046-1054

10.1093/ehjdh/ztaf061 Get It

Abstract Aims Syncope remains a diagnostic challenge despite advancements in testing and treatment. Cardiac syncope is an independent predictor of mortality and can be difficult to distinguish from other causes of transient loss of consciousness (TLOC). This paper explores whether artificial intelligence (AI) can improve the evaluation and management of patients with syncope. Methods and results We conducted a literature review and incorporated the opinions of experts in the fields of syncope and AI. The cause of TLOC is often unclear, hospitalization criteria are ambiguous, diagnostic tests are frequently non-informative, and assessments are costly. Patients are left with unanswered questions and limited guidance. Artificial intelligence (AI) has the potential to optimize syncope evaluation by processing large data sets, detecting imperceptible patterns, and assisting clinicians. However, AI has limitations, including errors, lack of human empathy, and uncertain clinical utility. Liability issues further complicate its integration. We present three viewpoints: (i) AI is crucial for advancing syncope management; (ii) AI can enhance the patient experience; and (iii) AI in syncope care is inevitable. Conclusion Artificial intelligence may improve syncope diagnosis and management, particularly through machine learning–based test interpretation and wearable device data. However, it has yet to surpass human clinical judgment in complex decision-making. Current challenges include gaps in understanding syncope mechanisms, AI interpretability, generalizability, and clinical integration. Standardized diagnostic approaches, real-world validation, and curated data sets are essential for progress. Artificial intelligence may enhance efficiency and communication but raises concerns regarding confidentiality, bias, inequities, and legal implications.
Syncope Time Frames for Adverse Events after Emergency Department Presentation: An Individual Patient Data Meta-Analysis
Furlan, Ludovico , Trombetta, Lucia, Casazza, Giovanni , Dipaola, Franca , Furlan, Raffaello , Marta, Chiara , Numeroso, Filippo , Pérez‐Rodon, Jordi , Quinn, James , Reed, Matthew J. , Sheldon, Robert S. , Shen, Win‐Kuang , Sun, Benjamin , Solbiati, Monica , Solbiati, Monica , Dipaola, Franca , Furlan, Raffaello , Thiruganasambandamoorthy, Venkatesh , Ungar, Andrea , Costantino, Giorgio

Medicina | November 12, 2021 | Volume: 57 | Issue: 11 | Pages: 1235

10.3390/medicina57111235 Get It

Background and Objectives: Knowledge of the incidence and time frames of the adverse events of patients presenting syncope at the ED is essential for developing effective management strategies. The aim of the present study was to perform a meta-analysis of the incidence and time frames of adverse events of syncope patients. Materials and Methods: We combined individual patients’ data from prospective observational studies including adult patients who presented syncope at the ED. We assessed the pooled rate of adverse events at 24 h, 72 h, 7–10 days, 1 month and 1 year after ED evaluation. Results: We included nine studies that enrolled 12,269 patients. The mean age varied between 53 and 73 years, with 42% to 57% females. The pooled rate of adverse events was 5.1% (95% CI 3.4% to 7.7%) at 24 h, 7.0% (95% CI 4.9% to 9.9%) at 72 h, 8.4% (95% CI 6.2% to 11.3%) at 7–10 days, 10.3% (95% CI 7.8% to 13.3%) at 1 month and 21.3% (95% CI 15.8% to 28.0%) at 1 year. The pooled death rate was 0.2% (95% CI 0.1% to 0.5%) at 24 h, 0.3% (95% CI 0.1% to 0.7%) at 72 h, 0.5% (95% CI 0.3% to 0.9%) at 7–10 days, 1% (95% CI 0.6% to 1.7%) at 1 month and 5.9% (95% CI 4.5% to 7.7%) at 1 year. The most common adverse event was arrhythmia, for which its rate was 3.1% (95% CI 2.0% to 4.9%) at 24 h, 4.8% (95% CI 3.5% to 6.7%) at 72 h, 5.8% (95% CI 4.2% to 7.9%) at 7–10 days, 6.9% (95% CI 5.3% to 9.1%) at 1 month and 9.9% (95% CI 5.5% to 17) at 1 year. Ventricular arrhythmia was rare. Conclusions: The risk of death or life-threatening adverse event is rare in patients presenting syncope at the ED. The most common adverse events are brady and supraventricular arrhythmias, which occur during the first 3 days. Prolonged ECG monitoring in the ED in a short stay unit with ECG monitoring facilities may, therefore, be beneficial.
A Systematic Review of Noninvasive Electrocardiogram Monitoring Devices for the Evaluation of Suspected Cardiovascular Syncope
Trombetta, Lucia, Erba, Luca , Bozzano, Viviana , Barbic, Franca , Casazza, Giovanni , Dipaola, Franca , Furlan, Raffaello , Kenny, Rose Anne , Quinn, James , Sheldon, Robert S. , Shen, Win-Kuang, Sun, Benjamin , Thiruganasambandamoorthy, Venkatesh , Reed, Matthew J. , Solbiati, Monica , Sacco, Roberto M., Costantino, Giorgio , Raj, Satish R , Thiruganasambandamoorthy, Venkatesh , Kenny, Rose Anne , Dipaola, Franca , Furlan, Raffaello

Journal of Medical Devices | February 8, 2019 | Volume: 13 | Issue: 2 | Pages: No page available

10.1115/1.4042795 Get It

The aims of this study were (1) to identify research publications studying noninvasive electrocardiogram (ECG) monitoring devices, (2) to define and categorize current technology in noninvasive ECG recording, and (3) to discuss desirable noninvasive recording features for personalized syncope evaluation to guide technological advancement and future studies. We performed a systematic review of the literature that assessed noninvasive ECG-monitoring devices, regardless of the reason for monitoring. We performed an Internet search and corresponded with syncope experts and companies to help identify further eligible products. We extracted information about included studies and device features. We found 173 relevant papers. The main reasons for ECG monitoring were atrial fibrillation (n = 45), coronary artery disease (n = 10), syncope (n = 8), palpitations (n = 8), other cardiac diseases (n = 67), and technological aspects of monitoring (n = 35). We identified 198 devices: 5 hospital telemetry devices, 12 patches, 46 event recorders, 70 Holter monitors, 23 external loop recorders, 20 mobile cardiac outpatient telemetries, and 22 multifunctional devices. The features of each device were very heterogeneous. There are a large number of ECG-monitoring devices with different features available in the market. Our findings may help clinicians select the appropriate device for their patients. Since there are only a few published articles analyzing their usefulness in syncope patients, further research might improve their use in this clinical setting.