AbstractBackgroundRecipients of implantable cardioverter defibrillator (ICD) generator replacement with multiple medical comorbidities may be at higher risk of adverse outcomes that attenuate the benefit of ICD replacement. The aim of this investigation was to study the association between the Charlson comorbidity index (CCI) and outcomes after ICD generator replacement.MethodsAll patients undergoing first ICD generator replacement at Mayo Clinic, Rochester and Beth Israel Deaconess Medical Center, Boston between 2001 and 2011 were identified. Outcomes included: (a) all‐cause mortality, (b) appropriate ICD therapy, and (c) death prior to appropriate therapy. Multivariable Cox regression analysis was performed to assess association between CCI and outcomes.ResultsWe identified 1421 patients with mean age of 69.6 ± 12.1 years, 81% male and median (range) CCI of 3 (0‐18). During a mean follow‐up of 3.9 ± 3 years, 52% of patients died, 30.6% experienced an appropriate therapy, and 23.6% died without experiencing an appropriate therapy. In multivariable analysis, higher CCI score was associated with increased all‐cause mortality (Hazard ratio, HR 1.10 [1.06‐1.13] per 1 point increase in CCI, P < .001), death without prior appropriate therapy (HR 1.11 [1.07‐1.15], P < .0001), but not associated with appropriate therapy (HR 1.01 [0.97‐1.05], P = .53). Patients with CCI ≥5 had an annual risk of death of 12.2% compared to 8.7% annual rate of appropriate therapy.ConclusionsCCI is predictive of mortality following ICD generator replacement. The benefit of ICD replacement in patients with CCI score ≥5 should be investigated in prospective studies.
Abstract PD4-05: Molecular breast imaging and tomosynthesis to eliminate the reservoir of undetected cancer in dense breasts: The Density MATTERS trial
Abstract Background High mammographic breast density is the primary reason for missed cancers or delayed detection on mammography, and is associated with a higher rate of advanced and interval cancers which increase breast cancer mortality. Digital breast tomosynthesis (DBT) has been shown to reduce false positive findings relative to 2D mammography but does not eliminate the potential for tumor masking in dense breasts due to the similar x-ray attenuation characteristics of tumors and normal fibroglandular tissue. Molecular Breast Imaging (MBI) performed with a dedicated gamma camera to detect functional uptake of a radiotracer, Tc-99m sestamibi, has been shown to reveal breast cancers obscured by density on mammography. In single-institution studies, adding MBI to 2D mammography in women with dense breasts detected an additional 5 to10 invasive cancers per 1000 screened, with modest increases in recall rate (6 to 8%) at a lower cost-per-cancer detected than mammography alone. Despite this promising evidence, the lack of multicenter trial data has limited wider acceptance. Also, MBI has yet to be compared to DBT, which in some centers has replaced 2D mammography screening. We present interim results from a multicenter trial comparing cancer detection rate of DBT and MBI in screening of women with mammographically dense breasts. Methods In this ongoing, prospective, multicenter clinical trial, asymptomatic women aged 40-75 years with dense breasts on prior mammogram and no prior history of supplemental screening are invited to undergo two annual rounds of concurrent DBT and MBI. MBI is performed with injection of 300 MBq Tc-99m sestamibi with a dual-head semiconductor-based gamma camera. Screening tests are interpreted independently. Here, preliminary cancer detection rates (cancers per 1000 women screened), recall rates, and biopsy rates of DBT and MBI for initial screening are reported. Results In 537 women out of a planned 3000 who have completed the first round of screening, 7 cancers were detected: one by DBT only and 6 by MBI only, giving cancer detection rates of 1.9 for DBT vs. 11.2 for MBI and incremental cancer detection rate of 9.3 for MBI. The one DBT-only cancer was a node-negative 0.8 cm invasive lobular carcinoma. All 6 cancers detected by MBI were invasive; 5 of 6 were node negative (median size 1.0 cm; range 0.6 to 2.6 cm). Recall rate was 11% (60/537) for DBT alone; 16% (84/537) for MBI alone, and 21% (115/537) for the combination. Biopsy was prompted by DBT in 13 patients (PPV 8% [1/13]); by MBI in 23 patients (PPV 26% [6/23]); and by the combination of modalities in 33 (PPV 21% [7/33]). Conclusion These preliminary results demonstrate that MBI detects invasive breast cancers occult on DBT in dense breasts. Data from a second screening round will allow calculation of sensitivity and specificity, and determination of the impact of screening MBI in reducing advanced (> 2 cm) and interval cancers. Additional planned analyses will evaluate a denoising algorithm for further reduction in MBI radiation dose to match that of DBT. Citation Format: Rhodes D, Hunt K, Conners A, Zingula S, Whaley D, Ellis R, Gasal Spilde J, Mehta R, Polley M-Y, O'Connor M, Hruska C. Molecular breast imaging and tomosynthesis to eliminate the reservoir of undetected cancer in dense breasts: The Density MATTERS trial [abstract]. In: Proceedings of the 2018 San Antonio Breast Cancer Symposium; 2018 Dec 4-8; San Antonio, TX. Philadelphia (PA): AACR; Cancer Res 2019;79(4 Suppl):Abstract nr PD4-05.
Outcomes After Implantable Cardioverter-Defibrillator Generator Replacement for Primary Prevention of Sudden Cardiac Death
Background— The effectiveness of implantable cardioverter-defibrillators (ICDs) for primary prevention of sudden death in patients with an ejection fraction (EF) ≤35% and clinical heart failure is well established. However, outcomes after replacement of the ICD generator in patients with recovery of EF to >35% and no previous therapies are not well characterized. Methods and Results— Between 2001 and 2011, generator replacement was performed at 2 tertiary medical centers in 253 patients (mean age, 68.3±12.7 years; 82% men) who had previously undergone ICD placement for primary prevention but subsequently never received appropriate ICD therapy. EF had recovered to >35% in 72 of 253 (28%) patients at generator replacement. During median (quartiles) follow-up of 3.3 (1.8–5.3) years after generator replacement, 68 of 253 (27%) experienced appropriate ICD therapy. Patients with EF ≤35% were more likely to experience ICD therapy compared with those with EF >35% (12% versus 5% per year; hazard ratio, 3.57; P =0.001). On multivariable analysis, low EF predicted appropriate ICD therapy after generator replacement (hazard ratio, 1.96 [1.35–2.87] per 10% decrement; P =0.001). Death occurred in 25% of patients 5 years after generator replacement. Mortality was similar in patients with EF ≤35% and >35% (7% versus 5% per year; hazard ratio, 1.10; P =0.68). Atrial fibrillation (3.24 [1.63–6.43]; P <0.001) and higher blood urea nitrogen (1.28 [1.14–1.45] per increase of 10 mg/dL; P <0.001) were associated with mortality. Conclusions— Although approximately one fourth of patients with a primary prevention ICD and no previous therapy have EF >35% at the time of generator replacement, these patients continue to be at significant risk for appropriate ICD therapy (5% per year). These data may inform decisions on ICD replacement.
Risk of Appropriate Therapy and Death Before Therapy After Implantable Cardioverter-Defibrillator Generator Replacement
Background The decision to initially implant an implantable cardioverter-defibrillator (ICD) is informed by robust randomized controlled trials, but no such data exist to guide the decision to replace an ICD generator. In this study, we aimed to determine outcomes after ICD generator replacement. Methods All patients with ischemic or nonischemic cardiomyopathy who underwent ICD generator replacement from 2001 to 2011 at Mayo Clinic, MN, or Beth Israel Deaconess Medical Center, MA, were included. Outcomes included (1) appropriate therapy after generator replacement and (2) death before appropriate therapy after generator replacement. Cox proportional hazards modeling was used to determine the associations between patient characteristics and outcomes. Results In 1421 patients undergoing ICD generator replacement (mean±SD age 69.6±12.1 years, 81% male), appropriate therapy occurred after replacement in 435 patients (30.6%) over a mean follow-up of 2.7±2.6 years. Associated factors included lower left ventricular ejection fraction and history of appropriate therapy before generator replacement. Death before appropriate ICD therapy occurred in 336 (23.7%) patients. Older age, lower left ventricular ejection fraction, and noncardiac comorbidities, including diabetes mellitus, chronic lung disease, peripheral vascular disease, lower hemoglobin, and lower glomerular filtration rate, were associated with greater risk of death before appropriate therapy. A progressive increase in mortality was observed with aggregation of these noncardiac comorbidities. Conclusions The decision to replace the ICD should take into consideration not only left ventricular ejection fraction and history of ventricular arrhythmias, but also comorbid illnesses that may impact the duration and the quality of life.
207Clinical utility of performing magnetic resonance imaging in patients with cardiac implantable electronic devices in situ
Background: Use of magnetic resonance imaging (MRI) brain is restricted in patients with cardiovascular implantable electronic devices (CIEDs). We proposed to determine whether mortality difference exists for patients with non–MRI-conditional CIEDs undergoing brain MRI compared with controls. Methods and Results: Retrospective analysis of prospectively collected data was performed to compare all-cause mortality in patients with CIEDs undergoing brain MRI (CIED-MRI) with 3 control groups matched for age, sex, imaging year, and type of CIED: (1) no CIED, brain MRI (no–CIED-MRI); (2) CIED, brain computerized tomography (CT) scan (CIED-CT); and (3) no CIED, brain CT (no–CIED-CT). The primary outcome was a significant difference ( P <0.05) between estimated mortality rates. Secondary outcomes were changes in device function before and after brain MRI. The estimated all-cause mortality at 5 years for the CIED-MRI group [mean age (±SD), 68.2 years (15.3 years); 61.2% men] was not significantly different from patients who underwent CT with or without a device (CIED-CT group: hazard ratio, 0.814; 95% confidence interval, 0.593–1.117; P =0.2; no–CIED-CT group: hazard ratio, 1.149; 95% confidence interval, 0.818–1.613; P =0.4). There was a significant increase in mortality between CIED-MRI and no–CIED-MRI groups (hazard ratio, 1.463; 95% confidence interval, 1.019–2.099; P =0.04). Conclusions: Brain MRI in patients with CIEDs does not carry an increased mortality risk compared with brain CT and can be performed with adherence to appropriate procedural protocols.
Risk of Hypertension among First-Time Symptomatic Kidney Stone Formers
Background and objectives Prior work has suggested a higher risk of hypertension in kidney stone formers but lacked disease validation and adjustment for potential confounders. Certain types of stone formers may also be at higher risk of hypertension. Design, setting, participants, & measurements In our study, incident symptomatic stone formers in Olmsted County from 2000 to 2011 were manually validated by chart review and age and sex matched to Olmsted County controls. We followed up patients through November 20, 2015. Hypertension was also validated by manual chart review, and the risk of hypertension in stone formers compared with controls was assessed both univariately and after adjusting for comorbidities. The risk of hypertension among different subtypes of stone formers was also evaluated. Results Among 3023 coded stone formers from 2000 to 2011, a total of 1515 were validated and matched to 1515 controls (mean age was 45 years old, and 56% were men). After excluding those with baseline hypertension (20% of stone formers and 18% of controls), 154 stone formers and 110 controls developed hypertension. Median follow-up time was 7.8 years in stone formers and 9.6 years in controls. Stone formers were found to have a higher risk of hypertension compared with controls (hazard ratio, 1.50; 95% confidence interval, 1.18 to 1.92), even after adjusting for age, sex, body mass index, serum creatinine, CKD, diabetes, gout, coronary artery disease, dyslipidemia, tobacco use, and alcohol abuse (hazard ratio, 1.58; 95% confidence interval, 1.12 to 2.21). Results were similar after excluding patients who were ever on a thiazide diuretic (hazard ratio, 1.65; 95% confidence interval, 1.16 to 2.38). Stone composition, radiographic stone burden, number of subsequent stone events, and stone removal surgeries were not associated with hypertension ( P >0.05 for all). Conclusions The risk of hypertension was higher after the first symptomatic kidney stone event. However, kidney stone severity, type, and treatment did not associate with hypertension.
Pre- and Postoperative Predictors of Infection-Related Complications in Patients Undergoing Percutaneous Nephrolithotomy
Abstract INTRODUCTION High-sensitivity cardiac troponin assays have potent prognostic value in stable cardiovascular disease cohorts. Our objective was to assess the prognostic utility of a novel cardiac troponin I (cTnI) high-sensitivity assay, independently and in combination with amino-terminal pro–B-type natriuretic peptide (NT-proBNP), for the future development of heart failure and mortality in the general community. METHODS A well-characterized community-based cohort of 2042 participants underwent clinical assessment and echocardiographic evaluation. Baseline measurements of cTnI with a high-sensitivity assay and NT-proBNP were obtained in 1843 individuals. Participants were followed for new-onset heart failure and mortality with median (25th, 75th percentile) follow-up of 10.7 (7.9, 11.6) and 12.1 (10.4, 13.0) years, respectively. RESULTS When measured with a high-sensitivity assay, cTnI greater than the sex-specific 80th percentile was independently predictive of heart failure [hazard ratio 2.56 (95% confidence interval 1.88–3.50), P < 0.001] and mortality [1.91(1.49–2.46), P < 0.001] beyond conventional risk factors in this community-based cohort, with significant increases in the net reclassification improvement for heart failure. The prognostic utility of cTnI measured with a high-sensitivity assay goes beyond NT-proBNP, yet our data suggest that these 2 assays are complementary and most beneficial when evaluated together in identifying at-risk individuals in the community. CONCLUSIONS Our findings lay the foundation for prospective studies aimed at identification of individuals at high risk by use of a multimarker approach, followed by aggressive prevention strategies to prevent subsequent heart failure.