Most gene-based severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccines are nonreplicating vectors. They deliver the gene or messenger RNA to the cell to express the spike protein but do not replicate to amplify antigen production. This study tested the utility of replication in a vaccine by comparing replication-defective adenovirus (RD-Ad) and replicating single-cycle adenovirus (SC-Ad) vaccines that express the SARS-CoV-2 spike protein. SC-Ad produced 100 times more spike protein than RD-Ad and generated significantly higher antibodies against the spike protein than RD-Ad after single immunization of Ad-permissive hamsters. SC-Ad–generated antibodies climbed over 14 weeks after single immunization and persisted for more than 10 months. When the hamsters were challenged 10.5 months after single immunization, a single intranasal or intramuscular immunization with SC-Ad-Spike reduced SARS-CoV-2 viral loads and damage in the lungs and preserved body weight better than vaccination with RD-Ad-Spike. This demonstrates the utility of harnessing replication in vaccines to amplify protection against infectious diseases.
Acinetobacter baumannii Genomic Sequence-Based Core Genome Multilocus Sequence Typing Using Ridom SeqSphere+ and Antimicrobial Susceptibility Prediction in ARESdb
Whole-genome sequencing (WGS) is rapidly replacing traditional typing methods for the investigation of infectious disease outbreaks. Additionally, WGS data are being used to predict phenotypic antimicrobial susceptibility. Acinetobacter baumannii , which is often multidrug-resistant, is a significant culprit in outbreaks in health care settings.
Detection of Pathogenic Bacteria From Septic Patients Using 16S Ribosomal RNA Gene–Targeted Metagenomic Sequencing
Abstract Background Conventional blood cultures were compared to plasma cell-free DNA–based 16S ribosomal RNA (rRNA) gene polymerase chain reaction (PCR)/next-generation sequencing (NGS) for detection and identification of potential pathogens in patients with sepsis. Methods Plasma was prospectively collected from 60 adult patients with sepsis presenting to the Mayo Clinic (Minnesota) Emergency Department from March through August 2019. Results of routine clinical blood cultures were compared to those of 16S rRNA gene NGS. Results Nineteen (32%) subjects had positive blood cultures, of which 13 yielded gram-negative bacilli, 5 gram-positive cocci, and 1 both gram-negative bacilli and gram-positive cocci. 16S rRNA gene NGS findings were concordant in 11. For the remaining 8, 16S rRNA gene NGS results yielded discordant detections (n = 5) or were negative (n = 3). Interestingly, Clostridium species were additionally detected by 16S rRNA gene NGS in 3 of the 6 subjects with gastrointestinal sources of gram-negative bacteremia and none of the 3 subjects with urinary sources of gram-negative bacteremia. In the 41 remaining subjects, 16S rRNA gene NGS detected at least 1 potentially pathogenic organism in 17. In 15, the detected microorganism clinically correlated with the patient’s syndrome. In 17 subjects with a clinically defined infectious syndrome, neither test was positive; in the remaining 7 subjects, a noninfectious cause of clinical presentation was identified. Conclusions 16S rRNA gene NGS may be useful for detecting bacteria in plasma of septic patients. In some cases of gram-negative sepsis, it may be possible to pinpoint a gastrointestinal or urinary source of sepsis based on the profile of bacteria detected in plasma.
Diagnostic Value of 16S Ribosomal RNA Gene Polymerase Chain Reaction/Sanger Sequencing in Clinical Practice
Abstract Background Accurate microbiologic diagnosis is important for appropriate management of infectious diseases. Sequencing-based molecular diagnostics are increasingly used for precision diagnosis of infections. However, their clinical utility is unclear. Methods We conducted a retrospective analysis of specimens that underwent 16S ribosomal RNA (rRNA) gene polymerase chain reaction (PCR) followed by Sanger sequencing at our institution from April 2017 through March 2019. Results A total of 566 specimens obtained from 460 patients were studied. Patients were considered clinically infected or noninfected based on final diagnosis and management. In 17% of patients, 16S rRNA PCR/sequencing was positive and in 5% of patients, this test led to an impact on clinical care. In comparison, bacterial cultures were positive in 21% of patients. Specimens with a positive Gram stain had 12 times greater odds of having a positive molecular result than those with a negative Gram stain (95% confidence interval for odds ratio, 5.2–31.4). Overall, PCR positivity was higher in cardiovascular specimens (37%) obtained from clinically infected patients, with bacterial cultures being more likely to be positive for musculoskeletal specimens (P < .001). 16S rRNA PCR/sequencing identified a probable pathogen in 10% culture-negative specimens. Conclusion 16S rRNA PCR/sequencing can play a role in the diagnostic evaluation of patients with culture-negative infections, especially those with cardiovascular infections.
Prospective Validation of PREDICT and Its Impact on the Transesophageal Echocardiography Use in Management of Staphylococcus aureus Bacteremia
Abstract Background Infective endocarditis (IE) is the most feared complication of Staphylococcus aureus bacteremia (SAB). Transesophageal echocardiogram (TEE) is generally recommended for all patients with SAB; however, supporting data for this are limited. We previously developed a scoring system, “PREDICT,” that quantifies the risk of IE and identifies patients who would most benefit most from undergoing TEE. The current prospective investigation aims to validate this score. Methods We prospectively screened all consecutive adults (≥18 years) hospitalized with SAB at 3 Mayo Clinic sites between January 2015 and March 2017. Results Of 220 patients screened, 199 with SAB met study criteria and were included in the investigation. Of them, 23 (11.6%) patients were diagnosed with definite IE within 12 weeks of initial presentation based on modified Duke’s criteria. Using the previously derived PREDICT model, the day 1 score of ≥4 had a sensitivity of 30.4% and a specificity of 93.8%, whereas a day 5 score of ≤2 had a sensitivity and negative-predictive value of 100%. Additional factors including surgery or invasive procedure in the past 30 days, prosthetic heart valve, and higher number of positive blood culture bottles in the first set of cultures were associated with increased risk of IE independent of the day 5 risk score. Conclusions We validated the previously developed PREDICT scoring tools for stratifying risk of IE, and the need for undergoing a TEE, among cases of SAB. We also identified other factors with predictive potential, although larger prospective studies are needed to further evaluate possible enhancements to the current scoring system.
Abstract Babesiosis is an emerging health risk, and clinicians need to be aware of its different clinical manifestations. In our cohort of 38 patients, almost half did not recall a tick bite, and diagnosis was delayed due to the nonspecific nature of symptoms. Sixty-eight percent of patients required hospitalization, with 21% requiring intensive care unit stay. Coinfection with Lyme, anaplasma, or both Lyme and anaplasma was seen in 24%, 5%, and 8% of the patients, respectively. None of the patients in our cohort died from their disease.
Long-term Outcomes of Patients With Human Herpesvirus 6 Encephalitis
Abstract Human herpesviruses 6 (HHV-6) A and B cause encephalitis in patients with hematologic malignancies, especially those undergoing allogeneic hematopoietic stem cell transplantation. In this cohort of 10 patients, persistent neurologic deficits associated with moderate to severe bilateral hippocampal atrophy were characteristic long-term findings, despite prolonged antiviral treatment.
Molecular Approach to Diagnosis of Cardiovascular Implantable Electronic Device Infection
Abstract Background Sonicate fluid (SF), a solution derived from vortexing and sonication of explanted cardiovascular implantable electronic devices (CIEDs), is a higher-yield specimen compared with swabs or tissues for culture-based detection of microorganisms associated with CIED infection. Despite this, SF culture fails to identify a causative organism in ~50% of cases. We aimed to evaluate the diagnostic performance of 16S ribosomal RNA gene (rRNA) polymerase chain reaction (PCR)/sequencing of SF and compare it with that of SF culture. Methods We identified 322 SF specimens from extracted CIEDs and reviewed clinical data for each patient. Subjects were classified as having or not having CIED infection. Cases were subcategorized as culture negative if no significant growth was reported from SF cultures and as culture positive if an organism was detected above predefined thresholds. 16S rRNA PCR/sequencing was performed, with the organisms identified reported according to Clinical and Laboratory Standards Institute guidelines for sequence data interpretation. Results A total of 278 SF samples corresponded to infected cases, of which 160 were culture positive and 118 culture negative. The remaining 44 were from noninfected cases, of which 2 were culture positive. Compared with SF culture, the sensitivity of 16S rRNA PCR/sequencing was higher (64% vs 57.5%, P = .003). 16S rRNA PCR/sequencing detected a potential pathogen in 28 of 118 culture-negative cases, identifying staphylococci in the majority (18/28). Conclusions 16S rRNA PCR/sequencing has higher sensitivity to detect bacteria in SF from extracted CIEDs than does SF culture.