Back to Authors

Humphries, Romney

0000-0002-6568-156X

Mayo Clinic

Vanderbilt University Medical Center

Citations 21

Considerations for Assessment and Deployment of Rapid Antigen Tests for Diagnosis of Coronavirus Disease 2019
Pollock, Nira R. , Lee, Francesca , Ginocchio, Christine C. , Yao, Joseph D. , Humphries, Romney M. , Humphries, Romney

Open Forum Infectious Diseases | March 11, 2021 | Volume: 8 | Issue: 6 | Pages: No page available

10.1093/ofid/ofab110 Get It

Abstract Diagnostic testing is a critical tool to mitigate the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic, but molecular testing capacity remains limited. Rapid diagnostic tests (RDTs) that detect SARS-CoV-2 protein antigens (Ag) offer the potential to substantially expand testing capacity and to allow frequent, large-scale, population screening. Testing is simple, rapid (results generally available within 15 minutes), and applicable for diagnosis at point of care. However, implementation of Ag RDTs requires a detailed understanding of test performance and operational characteristics in each testing scenario and population being evaluated. Successful implementation of Ag RDTs on a large scale should combine testing with technical oversight and with clinical and public health infrastructure, and will require production at levels much higher than presently possible. In this commentary, we provide detailed considerations for Ag RDT assessment and use cases to encourage and enable broader manufacturing and deployment.
Evaluation of the NG-Test MCR-1 Lateral Flow Assay and EDTA-Colistin Broth Disk Elution Methods To Detect Plasmid-Mediated Colistin Resistance among Gram-Negative Bacterial Isolates
Fenwick, Alexander J. , Bergman, Yehudit , Lewis, Shawna, Yee, Rebecca , Cole, Nicolynn C., Kohner, Peggy C., Ordak, Carly, Green, Daniel A. , Humphries, Romney M. , Simner, Patricia J. , Cole, Nicolynn, Kohner, Peggy, Green, Daniel A , Humphries, Romney , Uhlemann, Anne‐Catrin , Schuetz, Audrey N. , Bergman, Yehudit

Journal of Clinical Microbiology | January 24, 2020 | Volume: 58 | Issue: 4 | Pages: No page available

10.1128/jcm.01823-19 Get It

Plasmid-mediated colistin resistance (PMCR) is a global public health concern, given its ease of transmissibility. The purpose of this study was to evaluate two methods for the detection of PMCR from bacterial colonies: (i) the NG-Test MCR-1 lateral flow immunoassay (LFA; NG Biotech, Guipry, France) and (ii) the EDTA-colistin broth disk elution (EDTA-CBDE) screening test method. These methods were evaluated using a cohort of contemporary, clinical Gram-negative bacillus isolates from 3 U.S. academic medical centers (126 isolates of the Enterobacterales , 50 Pseudomonas aeruginosa isolates, and 50 Acinetobacter species isolates; 1 isolate was mcr positive) and 12 mcr -positive CDC-FDA Antibiotic Resistance (AR) Isolate Bank isolates for which reference broth microdilution colistin susceptibility results were available.
Evaluation of Calcium-Enhanced Media for Colistin Susceptibility Testing by Gradient Agar Diffusion and Broth Microdilution
Green, Daniel A. , Maćešić, Nenad , Lopez, Mabel, Stump, Stephania , Whittier, Susan , Simner, Patricia J. , Humphries, Romney M. , Humphries, Romney , Uhlemann, Anne‐Catrin , Lopez, Mabel, Schuetz, Audrey N.

Journal of Clinical Microbiology | November 20, 2019 | Volume: 58 | Issue: 2 | Pages: No page available

10.1128/jcm.01522-19 Get It

Despite the increasing reliance on polymyxin antibiotics (polymyxin B and colistin) for treatment of multidrug-resistant Gram-negative infections, many clinical laboratories are unable to perform susceptibility testing due to the lack of accurate and reliable methods. Although gradient agar diffusion is commonly performed for other antimicrobials, its use for polymyxins is discouraged due to poor performance characteristics.
Multicenter Evaluation of Colistin Broth Disk Elution and Colistin Agar Test: a Report from the Clinical and Laboratory Standards Institute
Humphries, Romney M. , Green, Daniel A. , Bergman, Yehudit , Lewis, Shawna, Yee, Rebecca , Stump, Stephania , Lopez, Mabel, Maćešić, Nenad , Uhlemann, Anne‐Catrin , Kohner, Peggy C., Cole, Nicolynn C., Simner, Patricia J. , Uhlemann, Anne-Catrin , Kohner, Peggy, Cole, Nicolynn, Humphries, Romney , Schuetz, Audrey N. , Lopez, Mabel, Bergman, Yehudit

Journal of Clinical Microbiology | September 10, 2019 | Volume: 57 | Issue: 11 | Pages: No page available

10.1128/jcm.01269-19 Get It

Susceptibility testing of the polymyxins (colistin and polymyxin B) is challenging for clinical laboratories. The Clinical and Laboratory Standards Institute (CLSI) Antimicrobial Susceptibility Testing Subcommittee evaluated two methods to enable accurate testing of these agents. These methods were a colistin broth disk elution (CBDE) and a colistin agar test (CAT), the latter of which was evaluated using two inoculum volumes, 1 μl (CAT-1) and 10 μl (CAT-10).
Candida auris: An Emerging Yeast Pathogen Posing Distinct Challenges for Laboratory Diagnostics, Treatment, and Infection Prevention
Hata, D. Jane , Humphries, Romney M. , Humphries, Romney, Lockhart, Shawn R. , Humphries, Romney

Archives of Pathology & Laboratory Medicine | June 6, 2019 | Volume: 144 | Issue: 1 | Pages: 107-114

10.5858/arpa.2018-0508-ra Get It

Context.— Candida auris is an emerging yeast species that was first described in 2009. This ascomycetous yeast is notable for resistance to azole antifungal agents, for environmental persistence, and for its ability to contaminate health care environments, resulting in patient colonization and nosocomial infections. Objective.— To review the state of current knowledge addressing challenges in the accurate identification of C auris in the diagnostic microbiology laboratory, including application of phenotypic, proteomic, and genomic methodologies; characteristics that may predispose the human host to acquiring C auris; transmission; clinical presentations; treatment modalities; environmental decontamination; and infection prevention in health care settings. Data Sources.— The PubMed search engine was used to access peer-reviewed literature published from 2009 to 2019. Conclusions.— The rapid emergence of C auris has presented unique challenges for the areas of laboratory diagnostics and infection prevention and in options for antifungal treatment, which are limited. The current lack of established antifungal susceptibility test breakpoints complicates therapeutic decision making. Enhanced awareness of this pathogen is essential to monitor outbreaks and to reduce the risk of spread within health care environments.
Multicenter Evaluation of the Accelerate PhenoTest BC Kit for Rapid Identification and Phenotypic Antimicrobial Susceptibility Testing Using Morphokinetic Cellular Analysis
Pancholi, Preeti , Dhiman, Neelam , Ford, Bradley , Granato, Paul A. , Harrington, Amanda, Hernandez, Diana R. , Humphries, Romney M. , Jindra, Matthew R., Ledeboer, Nathan A., Miller, Shelley A. , Mochon, A. Brian, Morgan, Margie, Patel, Robin , Schreckenberger, Paul C., Stamper, Paul D. , Simner, Patricia J. , Tucci, Nancy E., Zimmerman, Cynthia, Wolk, Donna M. , Buchan, Blake W , Granato, Paul A , Hernandez, Diana R , Wolk, Donna M , Patel, Robin , Humphries, Romney , Carroll, Karen C. , Chan, Raymond C.

Journal of Clinical Microbiology | January 8, 2018 | Volume: 56 | Issue: 4 | Pages: No page available

10.1128/jcm.01329-17 Get It

ABSTRACT We describe results from a multicenter study evaluating the Accelerate Pheno system, a first of its kind diagnostic system that rapidly identifies common bloodstream pathogens from positive blood cultures within 90 min and determines bacterial phenotypic antimicrobial susceptibility testing (AST) results within ∼7 h. A combination of fresh clinical and seeded blood cultures were tested, and results from the Accelerate Pheno system were compared to Vitek 2 results for identification (ID) and broth microdilution or disk diffusion for AST. The Accelerate Pheno system accurately identified 14 common bacterial pathogens and two Candida spp. with sensitivities ranging from 94.6 to 100%. Of fresh positive blood cultures, 89% received a monomicrobial call with a positive predictive value of 97.3%. Six common Gram-positive cocci were evaluated for ID. Five were tested against eight antibiotics, two resistance phenotypes (methicillin-resistant Staphylococcus aureus and Staphylococcus spp. [MRSA/MRS]), and inducible clindamycin resistance (MLSb). From the 4,142 AST results, the overall essential agreement (EA) and categorical agreement (CA) were 97.6% and 97.9%, respectively. Overall very major error (VME), major error (ME), and minor error (mE) rates were 1.0%, 0.7%, and 1.3%, respectively. Eight species of Gram-negative rods were evaluated against 15 antibiotics. From the 6,331 AST results, overall EA and CA were 95.4% and 94.3%, respectively. Overall VME, ME, and mE rates were 0.5%, 0.9%, and 4.8%, respectively. The Accelerate Pheno system has the unique ability to identify and provide phenotypic MIC and categorical AST results in a few hours directly from positive blood culture bottles and support accurate antimicrobial adjustment.
Direct-from-Blood-Culture Disk Diffusion To Determine Antimicrobial Susceptibility of Gram-Negative Bacteria: Preliminary Report from the Clinical and Laboratory Standards Institute Methods Development and Standardization Working Group
Chandrasekaran, Sukantha , Campeau, Shelley, Zimmer, Barbara L., Weinstein, Melvin P., Thrupp, Lauri, Hejna, John, Walker, Lindsey, Ammann, Tracy, Kirn, Thomas, Patel, Robin , Humphries, Romney M. , Patel, Robin , Humphries, Romney , Abbott, April N. , Zimmer, Barbara L., Walker, Lindsey, Kirn, Thomas

Journal of Clinical Microbiology | January 5, 2018 | Volume: 56 | Issue: 3 | Pages: No page available

10.1128/jcm.01678-17 Get It

ABSTRACT The performance of a disk diffusion test using broth from positive blood cultures as inoculum (direct disk diffusion [dDD]) was evaluated for a collection of 20 challenge isolates of Enterobacteriaceae , Acinetobacter baumannii , and Pseudomonas aeruginosa . Isolates seeded into human blood were inoculated into Bactec Plus Aerobic/F, VersaTREK Redox 1, and BacT/Alert FA Plus bottles and incubated in the respective automated blood culture systems. Disk diffusion results were compared to reference disk diffusion results. Categorical agreement (CA) values for dDD, after removal of random errors due to natural MIC variation, were 87.8%, 88.4%, and 92.2% for the BacT/Alert, Bactec, and VersaTREK systems, respectively. No very major errors (VME) were observed, and major error (ME) rates were 3.0%, 2.3%, and 1.7%, respectively. Incubation of the dDD test samples for 6 h compared to incubation for 16 to 18 h resulted in 19.9% of tests having too light of growth to allow reading of zones of inhibition. Among the evaluable dDD tests, CA values were 58.9%, 76.6%, and 73.2% for the isolates seeded into the BacT/Alert, Bactec, and VersaTREK systems, respectively. VME rates for isolates seeded into these systems were 2.2%, 1.8%, and 3.0%, respectively, and ME rates were 25.4%, 6.1%, and 2.8%, respectively, at the 6-h reading. The best performance of dDD was found for blood cultures with bacterial concentrations in the range of 7.6 × 10 7 to 5.0 × 10 8 CFU/ml; CA values ranged from 94.7 to 96.2% for these concentrations after 18 h of incubation and from 76.9 to 84.1% after 6 h of incubation. These preliminary data demonstrate the potential accuracy of dDD testing by the clinical laboratory.
Multicenter Performance Assessment of Carba NP Test
Cunningham, Scott A. , Limbago, Brandi, Traczewski, Maria M., Anderson, Karen, Hackel, Meredith , Hindler, Janet A., Sahm, Dan, Alyanak, Efe, Lawsin, Adrian , Man, Tom J. B. de , Mandrekar, Jayawant N. , Jenkins, Stephen G., Humphries, Romney M. , Palavecino, Elizabeth , Patel, Robin , Vasoo, Shawn , Gulvik, Christopher A. , Schuetz, Audrey N. , Patel, Robin , Humphries, Romney , Cunningham, Scott A

Journal of Clinical Microbiology | April 13, 2017 | Volume: 55 | Issue: 6 | Pages: 1954-1960

10.1128/jcm.00244-17 Get It

ABSTRACT Eighty Gram-negative bacilli (54 Enterobacteriaceae and 26 nonfermenting Gram-negative bacilli) obtained from multiple institutions in the United States were distributed in a blinded manner to seven testing laboratories to compare their performance of a test for detection of carbapenemase production, the Carba NP test. The Carba NP test was performed by all laboratories, following the Clinical and Laboratory Standards Institute (CLSI) procedure. Site-versus-site comparisons demonstrated a high level of consistency for the Carba NP assay, with just 3/21 site comparisons yielding a difference in sensitivity ( P < 0.05). Previously described limitations with bla OXA-48-like carbapenemases and bla OXA carbapenemases associated with Acinetobacter baumannii were noted. Based on these data, we demonstrate that the Carba NP test, when implemented with the standardized CLSI methodology, provides reproducible results across multiple sites for detection of carbapenemases.
Multicenter Evaluation of a Modified Cefoxitin Disk Diffusion Method and PBP2a Testing To Predict mecA -Mediated Oxacillin Resistance in Atypical Staphylococcus aureus
Miller, Shelley A. , Kohner, Peggy C., Cole, Nicolynn C., Hindler, Janet A., Patel, Robin , Richter, Sandra S. , Humphries, Romney M. , Kohner, Peggy, Cole, Nicolynn, Karichu, James K. , Patel, Robin , Humphries, Romney

Journal of Clinical Microbiology | December 1, 2016 | Volume: 55 | Issue: 2 | Pages: 485-494

10.1128/jcm.02211-16 Get It

ABSTRACT Phenotypic variants of Staphylococcus aureus that display small colonies, reduced pigmentation, and decreased hemolysis and/or coagulase activity are periodically isolated by the clinical laboratory. Antimicrobial susceptibility testing (AST) of these isolates is complicated, because many do not grow on routine AST media, including Mueller-Hinton agar (MHA) and cation-adjusted Mueller-Hinton broth. This multicenter study evaluated cefoxitin disk diffusion for 37 atypical S. aureus isolates (156 readings) with MHA supplemented with 5% sheep's blood (BMHA), using mecA PCR as the reference standard. The correlation of two commercial PBP2a assays with mecA PCR was also assessed. Ten isolates were negative and 27 positive for mecA . No major errors for cefoxitin were observed, but 19.5% very major errors (VMEs) were observed at 24 h of incubation, and 17.2% VMEs were observed at 48 h. The proportions of VMEs ranged from 14.7 to 23.0% at 24 h, and from 13.3 to 17.6% at 48 h, across three testing laboratories. PBP2a tests were performed from growth on BMHA and blood agar plates (BAP), with and without cefoxitin disk induction. The Alere PBP2a SA culture colony test sensitivities for mecA were 90.0% with uninduced growth and 97.4% with induced growth from BMHA. On BAP, sensitivity was 96.0% with induced growth. The sensitivities of the Oxoid PBP2′ latex agglutination test were 85.7% with uninduced growth and 93.9% with induced growth from BMHA and 95.9% with induced growth on BAP. On the basis of these data, we recommend that laboratories perform only mecA PCR and/or PBP2a tests when requested to perform AST on atypical isolates of S. aureus .