Back to Authors

Hindler, Janet A.

Mayo Clinic

Los Angeles County Department of Public Health

Citations 3

Overview of changes in the Clinical and Laboratory Standards Institute Performance Standards for Antimicrobial Susceptibility Testing: M100 32nd and 33rd editions
Schuetz, Audrey N. , Ferrell, Andrea , Hindler, Janet A., Humphries, Romney M. , Bobenchik, April M. , Humphries, Romney , Schuetz, Audrey N

Journal of Clinical Microbiology | August 7, 2025 | Volume: 63 | Issue: 9 | Pages: No page available

10.1128/jcm.01623-23 Get It

ABSTRACT The Clinical and Laboratory Standards Institute Subcommittee on Antimicrobial Susceptibility Testing (AST) publishes annual updates to the M100 Performance Standards for Antimicrobial Susceptibility Testing . This important document contains key information critical to the laboratory’s performance of accurate and current AST. This minireview will highlight and provide supporting data for major changes in the M100 32nd and 33rd editions published in February 2022 and March 2023, respectively. New and revised breakpoints for gram-negative and gram-positive organisms are explained. Proper use of the restructured M100 Table 1 guidance for antimicrobial agents to be considered for testing and reporting is outlined. Reporting guidance for multidrug-resistant gram-negative bacilli is discussed. Other topics within this minireview include additional agents to test and report for direct blood disk diffusion of gram-negative bacilli and quality control range changes and troubleshooting. The minireview concludes with other issues under consideration by the AST Subcommittee.
Multicenter Performance Assessment of Carba NP Test
Cunningham, Scott A. , Limbago, Brandi, Traczewski, Maria M., Anderson, Karen, Hackel, Meredith , Hindler, Janet A., Sahm, Dan, Alyanak, Efe, Lawsin, Adrian , Man, Tom J. B. de , Mandrekar, Jayawant N. , Jenkins, Stephen G., Humphries, Romney M. , Palavecino, Elizabeth , Patel, Robin , Vasoo, Shawn , Gulvik, Christopher A. , Schuetz, Audrey N. , Patel, Robin , Humphries, Romney , Cunningham, Scott A

Journal of Clinical Microbiology | April 13, 2017 | Volume: 55 | Issue: 6 | Pages: 1954-1960

10.1128/jcm.00244-17 Get It

ABSTRACT Eighty Gram-negative bacilli (54 Enterobacteriaceae and 26 nonfermenting Gram-negative bacilli) obtained from multiple institutions in the United States were distributed in a blinded manner to seven testing laboratories to compare their performance of a test for detection of carbapenemase production, the Carba NP test. The Carba NP test was performed by all laboratories, following the Clinical and Laboratory Standards Institute (CLSI) procedure. Site-versus-site comparisons demonstrated a high level of consistency for the Carba NP assay, with just 3/21 site comparisons yielding a difference in sensitivity ( P < 0.05). Previously described limitations with bla OXA-48-like carbapenemases and bla OXA carbapenemases associated with Acinetobacter baumannii were noted. Based on these data, we demonstrate that the Carba NP test, when implemented with the standardized CLSI methodology, provides reproducible results across multiple sites for detection of carbapenemases.
Multicenter Evaluation of a Modified Cefoxitin Disk Diffusion Method and PBP2a Testing To Predict mecA -Mediated Oxacillin Resistance in Atypical Staphylococcus aureus
Miller, Shelley A. , Kohner, Peggy C., Cole, Nicolynn C., Hindler, Janet A., Patel, Robin , Richter, Sandra S. , Humphries, Romney M. , Kohner, Peggy, Cole, Nicolynn, Karichu, James K. , Patel, Robin , Humphries, Romney

Journal of Clinical Microbiology | December 1, 2016 | Volume: 55 | Issue: 2 | Pages: 485-494

10.1128/jcm.02211-16 Get It

ABSTRACT Phenotypic variants of Staphylococcus aureus that display small colonies, reduced pigmentation, and decreased hemolysis and/or coagulase activity are periodically isolated by the clinical laboratory. Antimicrobial susceptibility testing (AST) of these isolates is complicated, because many do not grow on routine AST media, including Mueller-Hinton agar (MHA) and cation-adjusted Mueller-Hinton broth. This multicenter study evaluated cefoxitin disk diffusion for 37 atypical S. aureus isolates (156 readings) with MHA supplemented with 5% sheep's blood (BMHA), using mecA PCR as the reference standard. The correlation of two commercial PBP2a assays with mecA PCR was also assessed. Ten isolates were negative and 27 positive for mecA . No major errors for cefoxitin were observed, but 19.5% very major errors (VMEs) were observed at 24 h of incubation, and 17.2% VMEs were observed at 48 h. The proportions of VMEs ranged from 14.7 to 23.0% at 24 h, and from 13.3 to 17.6% at 48 h, across three testing laboratories. PBP2a tests were performed from growth on BMHA and blood agar plates (BAP), with and without cefoxitin disk induction. The Alere PBP2a SA culture colony test sensitivities for mecA were 90.0% with uninduced growth and 97.4% with induced growth from BMHA. On BAP, sensitivity was 96.0% with induced growth. The sensitivities of the Oxoid PBP2′ latex agglutination test were 85.7% with uninduced growth and 93.9% with induced growth from BMHA and 95.9% with induced growth on BAP. On the basis of these data, we recommend that laboratories perform only mecA PCR and/or PBP2a tests when requested to perform AST on atypical isolates of S. aureus .