Back to Authors

Urban, Matthew W

0000-0003-1360-4287

Mayo Clinic

Division of Radiology Research, Department of Radiology, Mayo Clinic, Rochester, Minn.

Citations 50

Selection of Breast Biopsy Markers: Effect on Breast Imaging Procedures, Follow-up, and Costs
Moseley, Tanya W. , Adrada, Beatriz E. , Arribas, Elsa , Hesley, Gina , Whitman, Gary J. , Rauch, Ronald A., Guirguis, Mary S. , Kapoor, Megha , Lee, Christine U. , Hesley, Gina K. , Arribas, Elsa M , Urban, Matthew W , Whitman, Gary J , Rauch, Ronald A , Guirguis, Mary S , Kapoor, Megha M , Lee, Christine , Adrada, Beatriz E , Urban, Matthew W.

RadioGraphics | August 13, 2026 | Volume: 46 | Issue: 9 | Pages: No page available

10.1148/rg.250151 Get It

Breast biopsy markers have evolved from simple metallic devices to sophisticated multimaterial tools that have become essential for breast cancer care, demonstrating their clinical benefits in surgical planning, radiation targeting, and cost reduction.
Quantitative viscoelastic assessment of copolymer-in-oil tissue-mimicking phantoms using plane-wave and ARFI-induced shear wave elastography
Prado, Mariah Eugênia Cosso da Silva , Collazos-Burbano, David A. , Uliana, Joao Henrique, Brum, Javier , Carneiro, Antônio Adilton Oliveira , Pavan, Theo Z. , Prado, M E C S , Collazos-Burbano, D A , Uliana, J H , Brum, J , Urban, Matthew W , Carneiro, A A O , Pavan, T Z , Urban, Matthew W.

Physics in Medicine & Biology | August 4, 2026 | Volume: 71 | Issue: 16 | Pages: 165015

10.1088/1361-6560/ae94da Get It

Abstract Tissue-mimicking phantoms play a crucial role in evaluating new imaging modalities, simulating clinical scenarios, and ensuring the quality and reliability of imaging systems. Styrene–ethylene/butylene–styrene (SEBS) is an extremely stable and versatile material that has been recently used in ultrasound, elastography, and photoacoustic imaging across diverse applications. Despite its extensive use, a systematic viscoelastic characterization of different SEBS-based formulations reported in the literature, particularly using shear wave elastography (SWE), remains limited. To address this gap, this study investigates the viscoelastic properties of tissue-mimicking phantoms composed of SEBS, glycerol dispersions in SEBS gels, and mixtures of SEBS with low-density polyethylene (LDPE) in mineral oil, using gelatin phantoms as a reference for comparison. Viscoelastic parameters were estimated from shear wave velocity and attenuation dispersion curves using a Kelvin–Voigt model, based on SWE measurements with acoustic radiation force (ARF) excitation, shear plane-wave excitation, and complementary mechanical testing. SEBS-based phantoms exhibited broad, composition-dependent viscoelastic tunability. Increasing SEBS or LDPE content led to stiffer and more viscous responses, while glycerol primarily modulated viscosity and, at higher concentrations, also affected stiffness. Consistent and concordant values were obtained using both ARF and plane wave SWE techniques. The resulting stiffness (2–22 kPa) and viscosity (0.01–1.24 Pa⋅s) overlaps with the mechanical properties of several biological soft tissues, supporting use of these phantoms for SWE validation.
Estimating shear wave speeds and shear viscosities with a viscoelastic time-domain method
Bannon, Nicholas A., McGough, Robert J., Urban, Matthew W , Urban, Matthew W.

The Journal of the Acoustical Society of America | June 16, 2026 | Volume: 159 | Issue: 6 | Pages: 5394-5407

10.1121/10.0044188 Get It

Shear wave elastography generates shear waves with an acoustic radiation force to obtain estimates of the shear wave speed. Shear wave elastography often utilizes time-of-flight calculations that apply cross-correlations or time-to-peak methods to obtain estimates of the shear wave speed in the time-domain. However, these time-domain methods fail to consider the effect of dispersion caused by the shear viscosity, which can introduce substantial errors into estimates of the shear wave speed. To solve this problem, a new viscoelastic method for estimating shear wave parameters in the time-domain is introduced. The performance of the new method, which is applied to shear wave particle velocity waveforms, is established by evaluating a simulated three-dimensional viscoelastic Green's function model for shear waves in the time-domain. Results show that the new viscoelastic time-domain method is applicable to locations outside of the push beam region at the focal depth and throughout a two-dimensional plane. The results also indicate that estimates of the shear wave speed are either comparable to or significantly improved relative to values obtained from cross-correlations while simultaneously providing estimates of the shear viscosity in the time-domain.
Robotic Ultrasound and Novel Collagen Analyses for Polycystic Kidney Disease Research Using Mice
Sussman, Caroline R. , Holmes, Heather L. , Stiller, Alison , Thao, Ka, Gregory, Adriana , Anaam, Deema , Meloche, Ryan , Mkhaimer, Yaman , Wells, Harrison H. , Vasconcelos, Luiz , Harris, Peter C. , Kline, Timothy L. , Romero, Michael F. , Gregory, Adriana V , Vasconcelos, Luiz , Urban, Matthew W , Macura, Slobodan I , Harris, Peter C , Kline, Timothy L , Romero, Michael F , Meloche, Ryan , Mkhaimer, Yaman G , Sussman, Caroline R. , Urban, Matthew W. , Macura, Slobodan

Kidney360 | August 12, 2024 | Volume: 5 | Issue: 10 | Pages: 1543-1552

10.34067/kid.0000000000000542 Get It

Key Points Robotic ultrasound performed favorably compared with magnetic resonance imaging for evaluating total kidney volume. Collagen evaluation by two novel methods of picrosirius red imaging were more informative than the standard method by brightfield imaging. Findings can improve research by increasing speed and access to total kidney volume determination and sensitivity of collagen assessment. Background 3D imaging and histology are critical tools for assessing polycystic kidney disease (PKD) in patients and animal models. Magnetic resonance (MR) imaging provides micron resolution but is time consuming and expensive, and access to equipment and expertise is limited. Robotic ultrasound (US) imaging has lower spatial resolution but is faster, more cost-effective, and accessible. Similarly, picrosirius red (PSR) staining and brightfield microscopy are commonly used to assess fibrosis; however, alternative methods have been shown in non-kidney tissues to provide greater sensitivity and more detailed structural characterization. Methods In this study, we evaluated the utility of robotic US and alternative methods of quantifying PSR staining for PKD research. We compared longitudinal total kidney volume measurements using US and MR imaging. We additionally compared PSR imaging and quantification using standard brightfield microscopy with that by circularly polarized light with hue analysis and fluorescence imaging analyzed using curvelet transform fiber extraction software for automatic detection of individual collagen fibers. Results Increased total kidney volume was detected by US in Pkd1 RC/RC versus wild-type (WT) at time points spanning from early to established disease. US interobserver variability was greater but allowed scanning in 2–5 minutes/mouse, whereas MR imaging required 20–30 minutes/mouse. While no change in fibrotic index was detected in this cohort of relatively mild disease using brightfield microscopy, polarized light showed fibers skewed thinner in Pkd1 RC/RC versus WT. Fluorescence imaging showed a higher density of collagen fibers in Pkd1 RC/RC versus WT, and fibers were thinner and curvier with no change in length. In addition, fiber density was higher in both glomeruli and tubules in Pkd1 RC/RC , and glomeruli had a higher fiber density than tubules in Pkd1 RC/RC and trended higher in WT. Conclusions These studies show robotic US is a rigorous imaging tool for preclinical PKD research. In addition, they demonstrate the increased sensitivity of polarized and fluorescence analysis of PSR-stained collagen.
Ultrasound Shear Elastography With Expanded Bandwidth (USEWEB): A Novel Method for 2D Shear Phase Velocity Imaging of Soft Tissues
Kijanka, Piotr , Urban, Matthew W. , Urban, Matthew W

IEEE Transactions on Medical Imaging | January 10, 2024 | Volume: 43 | Issue: 5 | Pages: 1910-1922

10.1109/tmi.2024.3352097 Get It

Evaluation of Robustness of S-Transform Based Phase Velocity Estimation in Viscoelastic Phantoms and Renal Transplants
Kijanka, Piotr , Vasconcelos, Luiz , Mandrekar, Jay , Urban, Matthew W. , Mandrekar, Jayawant N. , Vasconcelos, Luiz , Urban, Matthew W

IEEE Transactions on Biomedical Engineering | October 12, 2023 | Volume: 71 | Issue: 3 | Pages: 954-966

10.1109/tbme.2023.3323983 Get It

Comb Detection for Measuring Shear Wave Propagation
Lee, Hyoung-Ki , Holmes, Philip M. , Greenleaf, James F. , Urban, Matthew W. , Urban, Matthew W

IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control | July 20, 2023 | Volume: 70 | Issue: 9 | Pages: 1135-1145

10.1109/tuffc.2023.3297394 Get It

Using US Twinkling Artifact to Identify Breast Biopsy Markers: Brief Report
Lee, Christine U. , Moldoveanu, Dan , Urban, Matthew W. , Hesley, Gina K. , Hesley, Gina , Piltin, Mara A. , Urban, Matthew W

Radiology: Imaging Cancer | June 16, 2023 | Volume: 5 | Issue: 4 | Pages: No page available

10.1148/rycan.220168 Get It

Ultrasonographic Detection and Surgical Retrieval of a Nonmetallic Twinkle Marker in Breast Cancer: Pilot Study
Jakub, James W. , Hesley, Gina K. , Larson, Nicholas B. , Yaszemski, Michael J. , Greenleaf, James F. , Urban, Matthew W. , Lee, Christine U. , Hesley, Gina , Urban, Matthew W , Lee, Christine , Jakub, James W , Larson, Nicholas B , Miller, Alan Lee

Radiology: Imaging Cancer | November 11, 2022 | Volume: 4 | Issue: 6 | Pages: No page available

10.1148/rycan.220053 Get It

Measurement of wave propagation through a tube using dual transducers for elastography in arteries
Lee, Hyoung-Ki , Capron, Charles B, Liu, Hsiao‐Chuan , Roy, Tuhin , Guddati, Murthy N. , Greenleaf, James F., Urban, Matthew W. , Urban, Matthew W , Capron, Charles

Physics in Medicine & Biology | October 20, 2022 | Volume: 67 | Issue: 22 | Pages: 225010

10.1088/1361-6560/ac9c3f Get It

Abstract Objective. Measuring waves induced with acoustic radiation force (ARF) in arteries has been studied over the last decade. To date, it remains a challenge to quantitatively assess the local arterial biomechanical properties. The cylindrical shape and waveguide behavior of waves propagating in the arterial wall pose complexities to determining the mechanical properties of the artery. Approach . In this paper, an artery-mimicking tube in water is examined utilizing three-dimensional measurements. The cross-section of the tube is measured while a transducer is translated over 41 different positions along the length of the tube. Motion in the radial direction is calculated using two components of motion which are measured from the two orthogonal views of the cross-section. This enables more accurate estimation of motion along the circumference of tube. Main results . The results provide more information to categorize the motion in tube wall into two types of responses: a transient response and a steady state response. The transient response is caused by ARF application and the waves travel along the length of the tube for a relatively short period of time. This corresponds to the axial and circumferential propagating waves. The two circumferential waves travel along the circumference of tube in CW (clockwise) and CCW (counter-clockwise) direction and result in a standing wave. By using a directional filter, the two waves were successfully separated, and their propagation was more clearly visualized. As a steady state response, a circumferential mode is generated showing a symmetric motion (i.e. the proximal and distal walls move in the opposite direction) following the transient response. Significance. This study provides a more comprehensive understanding of the waves produced in an artery-mimicking tube with ARF application, which will provide opportunities for improving measurement of arterial mechanical properties.