Ultrasound shear wave elastography (SWE) is a useful technique for non-invasive tissue assessment. For effective quantitative analysis the employment of physical models is necessary for rheological parameter estimation, such as the Kelvin-Voigt (KV) model. From SWE data, the frequency response can be calculated, and the shear wave velocity dispersion can be fit, yielding the shear elasticity and shear viscosity, μ1 and μ2, respectively. In this study, a parametric evaluation is performed using staggered-grid finite-difference simulations of materials with μ1 = 1–25 kPa (increment: 1 kPa) and μ2 = 0–10 Pa s (increment: 0.5 Pa s), with an acoustic radiation force push of f-number equal to 2. The novel Stockwell transform combined with a slant frequency-wavenumber analysis (GST-SFK) was compared with the two-dimensional Fourier transform for dispersion curve estimation over a variety of frequency ranges. Regardless of dispersion curve estimation technique, the accuracy of estimating μ1 is confounded for μ2 values above 5 Pa s. It was found that KV fitting benefits from wider frequency ranges (up to 1kHz), with lower μ1 and μ2 estimation errors. The GST-SFK was the best dispersion curve calculation technique, yet the KV fitting process was found to be unreliable for parameter estimation in highly viscous media.
Mechanical properties in tissues are an important indicator because they are associated with disease states. One of the well-known excitation sources in optical coherence elastography (OCE) to determine mechanical properties is acoustic radiation force (ARF); however, a complicated focusing alignment cannot be avoided. Another excitation source is a piezoelectric (PZT) stack to obtain strain images via compression, which can affect the intrinsic mechanical properties of tissues in tissue engineering. In this study, we report a new technique called two-dimensional (2D) dynamic vibration OCE (DV-OCE) to evaluate 2D wave velocities without tedious focusing alignment procedures and is a non-contact method with respect to the samples. The three-dimensional (3D) Fourier transform was utilized to transfer the traveling waves (x, y, t) into 3D k-space (kx, ky, f). A spatial 2D wavenumber filter and multi-angle directional filter were employed to decompose the waves with omni-directional components into four individual traveling directions. The 2D local wave velocity algorithm was used to calculate a 2D wave velocity map. Six materials, two homogeneous phantoms with 10 mm thickness, two homogeneous phantoms with 2 mm thickness, one heterogeneous phantom with 2 mm diameter inclusion and an ex vivo porcine kidney, were examined in this study. In addition, the ARF-OCE was used to evaluate wave velocities for comparison. Numerical simulations were performed to validate the proposed 2D dynamic vibration OCE technique. We demonstrate that the experimental results were in a good agreement with the results from ARF-OCE (transient OCE) and numerical simulations. Our proposed 2D dynamic vibration OCE could potentially pave the way for mechanical evaluation in tissue engineering and for laboratory translation with easy-to-setup and contactless advantages.
Characterization of tissue mimicking phantoms and soft tissues using ultrasound shear wave elastography and power-law models
Characterization of mechanical properties of tissue has become an important area of study over the last two decades. Shear wave elastography (SWE) is being used in many clinical applications to characterize, and multiple mechanical properties are being reported. To more comprehensively characterize soft tissues, we have focused on frequency-domain methods for evaluating viscoelasticity. We measure the shear wave velocity and attenuation and the variation with frequency. We will present results with the Kelvin-Voigt fractional derivative model and general power laws to characterize data from SWE experiments in tissue-mimicking phantoms and exvivo and in vivo tissue. Tissue mimicking phantoms from CIRS, inc., that have varying amounts of viscoelasticity will be investigated. Measurements from ex vivo and in vivo liver and kidney will also be used for this study. We will examine the range of the power-law exponents associated with these samples and the different models to provide understanding of the range of these parameters and how well tissue mimicking phantoms realize the parameters measured in soft tissues.
Fluid surface tension evaluation using capillary wave measurement with optical coherence tomography
The surface tension of biological fluids is an important parameter because the mechanical properties of fluids are closely linked with hematological diseases and other pathophysiologies. Capillary waves are associated with fluid mechanical properties. Here, we propose a method that utilizes the acoustic radiation force (ARF) to generate propagating waves and optical coherence tomography (OCT) to measure the wave motion. This ARF-OCT method is capable of evaluating the surface tension of fluids, water and porcine whole blood in this study, based on the dispersion relation of capillary waves. Two-dimensional Fourier transforms were used to decompose frequency components of wave motion images to obtain a k-space representation and estimate the wave phase velocity. The phase velocity of capillary waves was obtained from the experimental results and compared to theoretical calculations. The surface tensions of water and porcine whole blood were determined from the experimental results. We first report that capillary waves measured with OCT can be a new promising modality for measuring the surface tension of fluids. The proposed method could be used to differentiate actual pathologic fluids or blood from those taken from healthy subjects and as a biomarker in future biomedical applications.
Acoustic radiation force optical coherence elastography for evaluating mechanical properties of soft condensed matters and its biological applications
AbstractEvaluating mechanical properties of biological soft tissues and viscous mucus is challenging because of complicated dynamic behaviors. Soft condensed matter models have been successfully used to explain a number of dynamical behaviors. Here, we reported that optical coherence elastography (OCE) is capable of quantifying mechanical properties of soft condensed matters, micellar fluids. A 7.5 MHz focused transducer was utilized to generate acoustic radiation force exerted on the surface of soft condensed matters in order to produce Rayleigh waves. The waves were recorded by optical coherence tomography (OCT). The Kelvin‐Voigt model was adopted to evaluate shear modulus and loss modulus of soft condensed matters. The results reported that various concentrations of micellar fluids can provide reasonable ranges of elasticity from 65.71 to 428.78 Pa and viscosity from 0.035 to 0.283 Pa·s, which are close to ranges for actual biological samples, like mucus. OCE might be a promising tool to differentiate pathologic mucus samples from healthy cases as advanced applications in the future.
Using multiparametric ultrasound-based elastographic characterization for evaluation of renal transplants
Renal transplant is a long-term therapy for patients in end-stage renal disease. Renal transplant health is monitored using laboratory tests and renal biopsy. However, renal biopsy is invasive and has issues with sampling errors. Ultrasound-based shear wave elastography (SWE) is being evaluated in renal transplants to identify patients with early stages of interstitial fibrosis and inflammation. We are exploring the use of new image reconstruction approaches such as local phase velocity imaging (LPVI) to evaluate viscoelasticity in a cohort of 23 renal transplants. Additionally, from point SWE measurements we have compiled results from 97 patients and have used various machine learning approaches to differentiate patients without disease such as interstitial fibrosis, inflammation, or interstitial fibrosis with tubular atrophy (IFTA). The LPVI method provides two-dimensional maps of phase velocity and images of viscoelastic parameters after fitting to a rheological model. The machine learning approaches combine multiple elastographic parameters to provide differentiation with high sensitivity, specificity, and accuracy (∼ 85%–90%). These approaches could have substantial benefit for patients for identifying early disease in renal transplants that my precede changes in laboratory test results.
Optical coherence elastography for evaluating Rayleigh wave propagation in soft matter-micellar fluids
Wormlike micellar (WM) fluids exhibit a self-assembly property and viscoelastic behavior which make them a promising material for representing biological fluids, ultrasoft tissue phantoms and drug delivery carriers. Although WM biochemistry has been investigated, the mechanical properties have been rarely discussed because of the complexity of soft matter systems. Here, we demonstrate that optical coherence elastography (OCE) is capable of measuring Rayleigh wave of micellar fluids. Three solutions with concentrations of 100, 200, 300 and 400 mM, were considered in the study. Ultrasound excitation to produce Rayleigh waves was accomplished using 7.5 MHz burst excitation signals of length 4.0 ms repeated at a rate of 19 Hz. The optical coherence tomography (OCT) acquisition was set to 50 lateral positions and 4000 A-scans for each lateral position at a 76 kHz scan rate for total acquisition time of 52.6 ms. Ultrasound-based shear wave elastography, implemented on a Verasonics system, was used to obtain group and phase velocity of the shear wave in all micellar fluids as reference. Our research results demonstrated that Rayleigh wave in micellar fluids can be evaluated by OCE and mechanical properties like Young’s modulus can be assessed. A wide of concentration ranges of WM fluids would provide a more realistic model to mimic biological fluids and tissues.