Back to Authors

Vasconcelos, Luiz

https://orcid.org/0000-0003-0013-1759

Mayo Clinic

Mayo Clinic

Citations 5

From Technical Performance to Clinical Readiness: A Phase-Based Framework for Evidence Standards in Clinical Artificial Intelligence
Nenadic, Ivan , Loring, Zak , Noseworthy, Peter A. , Ahmad, Faraz S. , Vasconcelos, Luiz , Fudim, Marat , Murthy, Venkatesh L. , Vasconcelos, Luiz , Noseworthy, Peter A , Ahmad, Faraz , Nenadic, Ivan

NEJM AI | September 17, 2026 | Volume: 3 | Issue: 10 | Pages: No page available

10.1056/aip2600684 Get It

Robotic Ultrasound and Novel Collagen Analyses for Polycystic Kidney Disease Research Using Mice
Sussman, Caroline R. , Holmes, Heather L. , Stiller, Alison , Thao, Ka, Gregory, Adriana , Anaam, Deema , Meloche, Ryan , Mkhaimer, Yaman , Wells, Harrison H. , Vasconcelos, Luiz , Harris, Peter C. , Kline, Timothy L. , Romero, Michael F. , Gregory, Adriana V , Vasconcelos, Luiz , Urban, Matthew W , Macura, Slobodan I , Harris, Peter C , Kline, Timothy L , Romero, Michael F , Meloche, Ryan , Mkhaimer, Yaman G , Sussman, Caroline R. , Urban, Matthew W. , Macura, Slobodan

Kidney360 | August 12, 2024 | Volume: 5 | Issue: 10 | Pages: 1543-1552

10.34067/kid.0000000000000542 Get It

Key Points Robotic ultrasound performed favorably compared with magnetic resonance imaging for evaluating total kidney volume. Collagen evaluation by two novel methods of picrosirius red imaging were more informative than the standard method by brightfield imaging. Findings can improve research by increasing speed and access to total kidney volume determination and sensitivity of collagen assessment. Background 3D imaging and histology are critical tools for assessing polycystic kidney disease (PKD) in patients and animal models. Magnetic resonance (MR) imaging provides micron resolution but is time consuming and expensive, and access to equipment and expertise is limited. Robotic ultrasound (US) imaging has lower spatial resolution but is faster, more cost-effective, and accessible. Similarly, picrosirius red (PSR) staining and brightfield microscopy are commonly used to assess fibrosis; however, alternative methods have been shown in non-kidney tissues to provide greater sensitivity and more detailed structural characterization. Methods In this study, we evaluated the utility of robotic US and alternative methods of quantifying PSR staining for PKD research. We compared longitudinal total kidney volume measurements using US and MR imaging. We additionally compared PSR imaging and quantification using standard brightfield microscopy with that by circularly polarized light with hue analysis and fluorescence imaging analyzed using curvelet transform fiber extraction software for automatic detection of individual collagen fibers. Results Increased total kidney volume was detected by US in Pkd1 RC/RC versus wild-type (WT) at time points spanning from early to established disease. US interobserver variability was greater but allowed scanning in 2–5 minutes/mouse, whereas MR imaging required 20–30 minutes/mouse. While no change in fibrotic index was detected in this cohort of relatively mild disease using brightfield microscopy, polarized light showed fibers skewed thinner in Pkd1 RC/RC versus WT. Fluorescence imaging showed a higher density of collagen fibers in Pkd1 RC/RC versus WT, and fibers were thinner and curvier with no change in length. In addition, fiber density was higher in both glomeruli and tubules in Pkd1 RC/RC , and glomeruli had a higher fiber density than tubules in Pkd1 RC/RC and trended higher in WT. Conclusions These studies show robotic US is a rigorous imaging tool for preclinical PKD research. In addition, they demonstrate the increased sensitivity of polarized and fluorescence analysis of PSR-stained collagen.
Evaluation of Robustness of S-Transform Based Phase Velocity Estimation in Viscoelastic Phantoms and Renal Transplants
Kijanka, Piotr , Vasconcelos, Luiz , Mandrekar, Jay , Urban, Matthew W. , Mandrekar, Jayawant N. , Vasconcelos, Luiz , Urban, Matthew W

IEEE Transactions on Biomedical Engineering | October 12, 2023 | Volume: 71 | Issue: 3 | Pages: 954-966

10.1109/tbme.2023.3323983 Get It

Using multiparametric ultrasound-based elastographic characterization for evaluation of renal transplants
Vasconcelos, Luiz , Vasconcelos, Luiz , Urban, Matthew W. , Kijanka, Piotr

The Journal of the Acoustical Society of America | November 14, 2019 | Volume: 146 | Issue: 4_Supplement | Pages: 2863-2863

10.1121/1.5136933 Get It

Renal transplant is a long-term therapy for patients in end-stage renal disease. Renal transplant health is monitored using laboratory tests and renal biopsy. However, renal biopsy is invasive and has issues with sampling errors. Ultrasound-based shear wave elastography (SWE) is being evaluated in renal transplants to identify patients with early stages of interstitial fibrosis and inflammation. We are exploring the use of new image reconstruction approaches such as local phase velocity imaging (LPVI) to evaluate viscoelasticity in a cohort of 23 renal transplants. Additionally, from point SWE measurements we have compiled results from 97 patients and have used various machine learning approaches to differentiate patients without disease such as interstitial fibrosis, inflammation, or interstitial fibrosis with tubular atrophy (IFTA). The LPVI method provides two-dimensional maps of phase velocity and images of viscoelastic parameters after fitting to a rheological model. The machine learning approaches combine multiple elastographic parameters to provide differentiation with high sensitivity, specificity, and accuracy (∼ 85%–90%). These approaches could have substantial benefit for patients for identifying early disease in renal transplants that my precede changes in laboratory test results.
In vivo open- and closed-chest measurements of left-ventricular myocardial viscoelasticity using lamb wave dispersion ultrasound vibrometry (LDUV): a feasibility study
Nenadic, Ivan , Pislaru, Cristina , Escobar, Daniel, Vasconcelos, Luiz , Greenleaf, James F. , Nenadic, Ivan Z, Urban, Matthew W. , Vasconcelos, Luiz , Pislaru, Cristina , Escobar, Daniel

Biomedical Physics & Engineering Express | April 16, 2018 | Volume: 4 | Issue: 4 | Pages: 047001

10.1088/2057-1976/aabe41 Get It

Abstract Diastolic dysfunction causes close to half of congestive heart failures and is associated with increased stiffness in left-ventricular myocardium. A clinical tool capable of measuring viscoelasticity of the myocardium could be beneficial in clinical settings. We used Lamb wave Dispersion Ultrasound Vibrometry (LDUV) for assessing the feasibility of making in vivo non-invasive measurements of myocardial elasticity and viscosity in pigs. In vivo open-chest measurements of myocardial elasticity and viscosity obtained using a Fourier space based analysis of Lamb wave dispersion are reported. The approach was used to perform ECG-gated transthoracic in vivo measurements of group velocity, elasticity and viscosity throughout a single heart cycle. Group velocity, elasticity and viscosity in the frequency range 50–500 Hz increased from diastole to systole, consistent with contraction and relaxation of the myocardium. Systolic group velocity, elasticity and viscosity were 5.0 m s −1 , 19.1 kPa, 6.8 Pa · s, respectively. In diastole, the measured group velocity, elasticity and viscosity were 1.5 m s −1 , 5.1 kPa and 3.2 Pa · s, respectively.