Back to Authors

Lee, Hyoung-Ki

https://orcid.org/0000-0001-7206-2081

Mayo Clinic

Mayo Clinic

Citations 3

Comparing in vivo wave-based elastography with ex vivo mechanical testing in porcine vessels
Capron, Charles , Lee, Hyoung-Ki , Tanner, Allison, Singh, Prabh G. , Kilari, Sreenivasulu , Liu, Gang , Roy, Tuhin, Guddati, Murthy N. , Misra, Sanjay, Urban, Matthew W.

The Journal of the Acoustical Society of America | November 28, 2023 | Volume: 154 | Issue: 4_supplement | Pages: A318-A318

10.1121/10.0023659 Get It

Arterial stiffness predicts cardiovascular disease, the leading cause of death worldwide. Ultrasound elastography methods that measure wave velocity have promise for evaluating the stiffness of blood vessels in vivo. However, vessel geometry modulates wave velocity by inducing geometric dispersion. Here, we compare Young's modulus E estimates obtained using in vivo wave velocity measurements and techniques that either do or do not consider geometry to ex vivo reference E values from mechanical testing . An acoustic radiation force was applied to generate propagating waves in the right common carotid artery (N = 9) and external jugular vein (N = 10) of anesthetized pigs. Vessels were imaged with ultrafast ultrasound to measure wave motion. Group velocity cg was estimated from wave motion using a Radon transform. E was estimated from cg using a bulk media assumption which neglects geometry, as well as the Moens–Korteweg equation and a semi-analytical finite element model, which consider geometry. Pigs were euthanized and vessels were excised. Ring-shaped samples were extracted and tested in a uniaxial tension setup to obtain reference E values for comparison with E values obtained from wave-based techniques. Techniques considering geometry exhibited higher correlation with reference E values, underscoring the need to incorporate geometry for accurate vascular elastography assessments.
Comb Detection for Measuring Shear Wave Propagation
Lee, Hyoung-Ki , Holmes, Philip M. , Greenleaf, James F. , Urban, Matthew W. , Urban, Matthew W

IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control | July 20, 2023 | Volume: 70 | Issue: 9 | Pages: 1135-1145

10.1109/tuffc.2023.3297394 Get It

Measurement of wave propagation through a tube using dual transducers for elastography in arteries
Lee, Hyoung-Ki , Capron, Charles B, Liu, Hsiao‐Chuan , Roy, Tuhin , Guddati, Murthy N. , Greenleaf, James F., Urban, Matthew W. , Urban, Matthew W , Capron, Charles

Physics in Medicine & Biology | October 20, 2022 | Volume: 67 | Issue: 22 | Pages: 225010

10.1088/1361-6560/ac9c3f Get It

Abstract Objective. Measuring waves induced with acoustic radiation force (ARF) in arteries has been studied over the last decade. To date, it remains a challenge to quantitatively assess the local arterial biomechanical properties. The cylindrical shape and waveguide behavior of waves propagating in the arterial wall pose complexities to determining the mechanical properties of the artery. Approach . In this paper, an artery-mimicking tube in water is examined utilizing three-dimensional measurements. The cross-section of the tube is measured while a transducer is translated over 41 different positions along the length of the tube. Motion in the radial direction is calculated using two components of motion which are measured from the two orthogonal views of the cross-section. This enables more accurate estimation of motion along the circumference of tube. Main results . The results provide more information to categorize the motion in tube wall into two types of responses: a transient response and a steady state response. The transient response is caused by ARF application and the waves travel along the length of the tube for a relatively short period of time. This corresponds to the axial and circumferential propagating waves. The two circumferential waves travel along the circumference of tube in CW (clockwise) and CCW (counter-clockwise) direction and result in a standing wave. By using a directional filter, the two waves were successfully separated, and their propagation was more clearly visualized. As a steady state response, a circumferential mode is generated showing a symmetric motion (i.e. the proximal and distal walls move in the opposite direction) following the transient response. Significance. This study provides a more comprehensive understanding of the waves produced in an artery-mimicking tube with ARF application, which will provide opportunities for improving measurement of arterial mechanical properties.