Back to Authors

Liu, Wei

0000-0003-0935-3999

Mayo Clinic

Mayo Clinic

Citations 18

Needs, Trends, and Advances in Scintillators for Radiographic Imaging and Tomography
Wang, ‪Zhehui , Dujardin, Christophe , Freeman, Matthew S. , Gehring, Amanda , Lecoq, P. , Liu, Wei , Melcher, Charles L. , Morris, C. L. , Nikl, M. , Robertson, Daniel , Rutstrom, Daniel , Watson, S. A., Wiggins, Brenden , Winch, Nicola M. , Liu, Wei , Hunter, J. F. , Pilania, Ghanshyam , Pokharel, Reeju , Sjue, Sky K. , Tremsin, Anton S. , Zhuravleva, Mariya

IEEE Transactions on Nuclear Science | June 28, 2023 | Volume: 70 | Issue: 7 | Pages: 1244-1280

10.1109/tns.2023.3290826 Get It

Feasibility of using megavoltage computed tomography to reduce proton range uncertainty: A simulation study
Hu, Yanle , Ding, Xiaoning, Shen, Jiajian , Liu, Wei , Kang, Yixiu, Yu, Lifeng , Bues, Martin , Liu, Wei , Shen, Jiajian , Leng, Shuai , Yu, Lifeng

Journal of Applied Clinical Medical Physics | February 20, 2021 | Volume: 22 | Issue: 3 | Pages: 131-140

10.1002/acm2.13191 Get It

AbstractPurposeTo demonstrate that variation in chemical composition has a negligible effect on the mapping curve from relative electron density (RED) to proton stopping power ratio (SPR), and to establish the theoretical framework of using Megavoltage (MV) computed tomography (CT), instead of kilovoltage (kV) dual energy CT, to accurately estimate proton SPR.MethodsA simulation study was performed to evaluate the effect of chemical composition variation on kVCT number and proton SPR. The simulation study involved both reference and simulated human tissues. The reference human tissues, together with their physical densities and chemical compositions, came from the ICRP publication 23. The simulated human tissues were created from the reference human tissues assuming that elemental percentage weight followed a Gaussian distribution. For all tissues, kVCT number and proton SPR were obtained through (a) theoretical calculation from tissue’s physical density and chemical composition which served as the ground truth, and (b) estimation from RED using the calibration curves established from the stoichiometric method. Deviations of the estimated values from the calculated values were quantified as errors in using RED to estimate kVCT number and proton SPR.ResultsGiven a chemical composition variation of 5% (1σ) of the nominal percentage weights, the total estimation error of using RED to estimate kVCT number was 0.34%, 0.62%, and 0.77% and the total estimation error of using RED to estimate proton SPR was 0.30%, 0.22%, and 0.16% for fat tissues, non‐fat soft tissues and bone tissues, respectively.ConclusionChemical composition had a negligible effect on the method of using RED to determine proton SPR. RED itself is sufficient to accurately determine proton SPR. MVCT number maintains a superb linear relationship with RED because it is highly dominated by Compton scattering. Therefore, MVCT has great potential in reducing the proton range uncertainty.
Beam angle comparison for distal esophageal carcinoma patients treated with intensity‐modulated proton therapy
Feng, Hongying , Rule, William G., Bhangoo, R.S. , Lara, Pedro, Patrick, Christopher L., Korte, Shawn M., Fatyga, M., Wong, William W. , Ashman, Jonathan B. , Bhangoo, Ronik S, Korte, Shawn, Fatyga, Mirek, Schild, Steven E. , Liu, Wei , Sio, Terence T. , Liu, Wei

Journal of Applied Clinical Medical Physics | October 15, 2020 | Volume: 21 | Issue: 11 | Pages: 141-152

10.1002/acm2.13049 Get It

Abstract Purpose To compare the dosimetric performances of intensity‐modulated proton therapy (IMPT) plans generated with two different beam angle configurations (the Right–Left oblique posterior beams and the Superior–Inferior oblique posterior beams) for the treatment of distal esophageal carcinoma in the presence of uncertainties and interplay effect. Methods and Materials Twenty patients’ IMPT plans were retrospectively selected, with 10 patients treated with the R‐L oblique posterior beams (Group R‐L) and the other 10 patients treated with the S‐I oblique posterior beams (Group S‐I). Patients in both groups were matched by their clinical target volumes (CTVs—high and low dose levels) and respiratory motion amplitudes. Dose‐volume‐histogram (DVH) indices were used to assess plan quality. DVH bandwidth was calculated to evaluate plan robustness. Interplay effect was quantified using four‐dimensional (4D) dynamic dose calculation with random respiratory starting phase of each fraction. Normal tissue complication probability (NTCP) for heart, liver, and lung was calculated, respectively, to estimate the clinical outcomes. Wilcoxon signed‐rank test was used for statistical comparison between the two groups. Results Compared with plans in Group R‐L, plans in Group S‐I resulted in significantly lower liver D mean and lung V 30Gy[RBE] with slightly higher but clinically acceptable spinal cord D max . Similar plan robustness was observed between the two groups. When interplay effect was considered, plans in Group S‐I performed statistically better for heart D mean and V 30Gy[RBE] , lung Dmean and V 5Gy[RBE] , and liver D mean , with slightly increased but clinically acceptable spinal cord D max . NTCP for liver was significantly better in Group S‐I. Conclusions IMPT plans in Group S‐I have better sparing of liver, heart, and lungs at the slight cost of spinal cord maximum dose protection, and are more interplay‐effect resilient compared to IMPT plans in Group R‐L. Our study supports the routine use of the S‐I oblique posterior beams for the treatments of distal esophageal carcinoma.
Expression of ICOSL is associated with decreased survival in invasive breast cancer
Wang, Bin , Jiang, Huayong , Zhou, Tingyang, Ma, Ning , Liu, Wei , Zuo, Li, Liu, Wei , Wang, Yajie

PeerJ | May 16, 2019 | Volume: 7 | Issue: No issue available | Pages: e6903

10.7717/peerj.6903 Get It

BackgroundInducible co-stimulator (ICOS) is a CD28-related molecule exclusively expressed on activated T cells and plays a critical role in modulating the immune response in breast cancer. The blockage of ICOS pathway has been shown to inhibit the activity of Type 2 T helper cells, thus potentially protecting against cancer growth. The current study aims to investigate the correlation between inducible co-stimulator ligand (ICOSL) expression in tumor tissues and the prognoses of patients with invasive breast cancer.MethodsTumor samples from 562 Chinese patients with invasive breast carcinomas were collected between 2003 and 2010. The expression of ICOSL on breast tumor and adjacent non-cancerous tissue was determined via immunohistochemistry. The overall survival (OS) of patients with positive and negative ICOSL expression were described using Kaplan–Meier curves, respectively. Parametric correlation method was used to analyze the correlation between ICOSL expression and other clinicopathological parameters. ICOSL was selected as a dependent variable for multivariate analysis.ResultsPositive ICOSL expression was identified on the plasma membrane in both cytoplasm and the nucleus of breast cancer cells. Membrane-expressed ICOSL is determined as an independent prognostic factor for OS in breast cancer but without significantly correlating with other clinicopathologic parameters such as age, menopausal status, depth of invasion, lymph node metastasis status, histologic classification, etc.ConclusionOur study suggests that the up-regulated expression of ICOSL protein in breast tumor cells can be associated with poor prognoses in invasive breast carcinomas.
Robust radiotherapy planning
Unkelbach, Jan , Alber, M., Bangert, Mark, Bokrantz, Rasmus, Chan, Timothy C. Y. , Deasy, Joseph O. , Fredriksson, Albin , Gorissen, Bram L. , Herk, Marcel van , Liu, Wei , Mahmoudzadeh, Houra , Nohadani, Omid , Siebers, Jeffrey V. , Xu, Huijun , Witte, Marnix , Xu, Huijun , Liu, Wei

Physics in Medicine & Biology | October 5, 2018 | Volume: 63 | Issue: 22 | Pages: 22TR02

10.1088/1361-6560/aae659 Get It

Abstract Motion and uncertainty in radiotherapy is traditionally handled via margins. The clinical target volume (CTV) is expanded to a larger planning target volume (PTV), which is irradiated to the prescribed dose. However, the PTV concept has several limitations, especially in proton therapy. Therefore, robust and probabilistic optimization methods have been developed that directly incorporate motion and uncertainty into treatment plan optimization for intensity modulated radiotherapy (IMRT) and intensity modulated proton therapy (IMPT). Thereby, the explicit definition of a PTV becomes obsolete and treatment plan optimization is directly based on the CTV. Initial work focused on random and systematic setup errors in IMRT. Later, inter-fraction prostate motion and intra-fraction lung motion became a research focus. Over the past ten years, IMPT has emerged as a new application for robust planning methods. In proton therapy, range or setup errors may lead to dose degradation and misalignment of dose contributions from different beams – a problem that cannot generally be addressed by margins. Therefore, IMPT has led to the first implementations of robust planning methods in commercial planning systems, making these methods available for clinical use. This paper first summarizes the limitations of the PTV concept. Subsequently, robust optimization methods are introduced and their applications in IMRT and IMPT planning are reviewed.
Comparison of linear and nonlinear programming approaches for “worst case dose” and “minmax” robust optimization of intensity‐modulated proton therapy dose distributions
Zaghian, Maryam, Cao, Wenhua , Liu, Wei , Kardar, Laleh, Randeniya, S, Mohan, Radhe , Lim, Gino J. , Liu, Wei

Journal of Applied Clinical Medical Physics | March 14, 2017 | Volume: 18 | Issue: 2 | Pages: 15-25

10.1002/acm2.12033 Get It

AbstractRobust optimization of intensity‐modulated proton therapy (IMPT) takes uncertainties into account during spot weight optimization and leads to dose distributions that are resilient to uncertainties. Previous studies demonstrated benefits of linear programming (LP) for IMPT in terms of delivery efficiency by considerably reducing the number of spots required for the same quality of plans. However, a reduction in the number of spots may lead to loss of robustness. The purpose of this study was to evaluate and compare the performance in terms of plan quality and robustness of two robust optimization approaches using LP and nonlinear programming (NLP) models. The so‐called “worst case dose” and “minmax” robust optimization approaches and conventional planning target volume (PTV)‐based optimization approach were applied to designing IMPT plans for five patients: two with prostate cancer, one with skull‐based cancer, and two with head and neck cancer. For each approach, both LP and NLP models were used. Thus, for each case, six sets of IMPT plans were generated and assessed: LP‐PTV‐based, NLP‐PTV‐based, LP‐worst case dose, NLP‐worst case dose, LP‐minmax, and NLP‐minmax. The four robust optimization methods behaved differently from patient to patient, and no method emerged as superior to the others in terms of nominal plan quality and robustness against uncertainties. The plans generated using LP‐based robust optimization were more robust regarding patient setup and range uncertainties than were those generated using NLP‐based robust optimization for the prostate cancer patients. However, the robustness of plans generated using NLP‐based methods was superior for the skull‐based and head and neck cancer patients. Overall, LP‐based methods were suitable for the less challenging cancer cases in which all uncertainty scenarios were able to satisfy tight dose constraints, while NLP performed better in more difficult cases in which most uncertainty scenarios were hard to meet tight dose limits. For robust optimization, the worst case dose approach was less sensitive to uncertainties than was the minmax approach for the prostate and skull‐based cancer patients, whereas the minmax approach was superior for the head and neck cancer patients. The robustness of the IMPT plans was remarkably better after robust optimization than after PTV‐based optimization, and the NLP‐PTV‐based optimization outperformed the LP‐PTV‐based optimization regarding robustness of clinical target volume coverage. In addition, plans generated using LP‐based methods had notably fewer scanning spots than did those generated using NLP‐based methods.
Evaluation of the systematic error in using 3D dose calculation in scanning beam proton therapy for lung cancer
Liu, Wei , Matney, J, Zhang, Xiaodong , Li, Yupeng , Zhu, Ronald X., Li, Heng , Park, Peter, Liao, Zhongxing , Chang, Joe Y. , Li, Yupeng, Liu, Wei

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 15 | Issue: 5 | Pages: 47-56

10.1120/jacmp.v15i5.4810 Get It

The objective of this study was to evaluate and understand the systematic error between the planned three‐dimensional (3D) dose and the delivered dose to patient in scanning beam proton therapy for lung tumors. Single‐field and multifield optimized scanning beam proton therapy plans were generated for ten patients with stage II‐III lung cancer with a mix of tumor motion and size. 3D doses in CT datasets for different respiratory phases and the time‐weighted average CT, as well as the four‐dimensional (4D) doses were computed for both plans. The 3D and 4D dose differences for the targets and different organs at risk were compared using dose‐volume histogram (DVH) and voxel‐based techniques, and correlated with the extent of tumor motion. The gross tumor volume (GTV) dose was maintained in all 3D and 4D doses, using the internal GTV override technique. The DVH and voxel‐based techniques are highly correlated. The mean dose error and the standard deviation of dose error for all target volumes were both less than 1.5% for all but one patient. However, the point dose difference between the 3D and 4D doses was up to 6% for the GTV and greater than 10% for the clinical and planning target volumes. Changes in the 4D and 3D doses were not correlated with tumor motion. The planning technique (single‐field or multifield optimized) did not affect the observed systematic error. In conclusion, the dose error in 3D dose calculation varies from patient to patient and does not correlate with lung tumor motion. Therefore, patient‐specific evaluation of the 4D dose is important for scanning beam proton therapy for lung tumors.PACS number: 87.55.D
Robust treatment planning with conditional value at risk chance constraints in intensity‐modulated proton therapy
An, Yu , Liang, Jianming , Bues, Martin , Liu, Wei , Schild, Steven E. , Liu, Wei , Bues, Martin

Medical Physics | January 3, 2017 | Volume: 44 | Issue: 1 | Pages: 28-36

10.1002/mp.12001 Get It

Background and purposeIntensity‐modulated proton therapy (IMPT) is highly sensitive to range uncertainties and uncertainties caused by setup variation. The conventional inverse treatment planning of IMPT based on the planning target volume (PTV) is not often sufficient to ensure robustness of treatment plans. We applied a probabilistic framework (chance‐constrained optimization) in IMPT planning to hedge against the influence of uncertainties.Material and methodsWe retrospectively selected one patient with lung cancer, one patient with head and neck (H&N) cancer, and one with prostate cancer for this analysis. Using their original images and prescriptions, we created new IMPT plans using two methods: (1) a robust chance‐constrained treatment planning method with the clinical target volume (CTV) as the target; (2) the margin‐based method with PTV as the target, which was solved by commercial software, CPLEX, using linear programming. For the first method, we reformulated the model into a tractable mixed‐integer programming problem and sped up the calculation using Benders decomposition. The dose‐volume histograms (DVHs) from the nominal and perturbed dose distributions were used to assess and compare plan quality. DVHs for all uncertain scenarios along with the nominal DVH were plotted. The width of the “bands” of DVHs was used to quantify the plan sensitivity to uncertainty. The newly developed Benders decomposition method was compared with a commercial solution to demonstrate its computational efficiency. The trade‐off between nominal plan quality and plan robustness was investigated.ResultsOur chance‐constrained model outperformed the PTV method in terms of tumor coverage, tumor dose homogeneity, and plan robustness. Our model was shown to produce IMPT plans to meet the dose‐volume constraints of organs at risk (OARs) and had better sparing of OARs than the PTV method in the three clinical cases included in this study. The chance‐constrained model provided a flexible tool for users to balance between plan robustness and plan quality. In addition, our in‐house developed method was found to be much faster than the commercial solution.ConclusionWith explicit control of plan robustness, the chance‐constrained robust optimization model generated superior IMPT plans compared to the PTV‐based method.