Abstract Objective Wearable nonelectroencephalographic biosignal recordings captured from the wrist offer enormous potential for seizure monitoring. However, signal quality remains a challenging factor affecting data reliability. Models trained for seizure detection depend on the quality of recordings in peri‐ictal periods in performing a feature‐based separation of ictal periods from interictal periods. Thus, this study aims to investigate the effect of epileptic seizures on signal quality, ensuring accurate and reliable monitoring. Methods This study assesses the signal quality of wearable data during peri‐ictal phases of generalized tonic–clonic and focal to bilateral tonic–clonic seizures (TCS), focal motor seizures (FMS), and focal nonmotor seizures (FNMS). We evaluated accelerometer (ACC) activity and the signal quality of electrodermal activity (EDA) and blood volume pulse (BVP) data. Additionally, we analyzed the influence of peri‐ictal movements as assessed by ACC (ACC activity) on signal quality and examined intraictal subphases of focal to bilateral TCS. Results We analyzed 386 seizures from 111 individuals in three international epilepsy monitoring units. BVP signal quality and ACC activity levels differed between all seizure types. We found the largest decrease in BVP signal quality and increase in ACC activity when comparing the ictal phase to the pre‐ and postictal phases for TCS. Additionally, ACC activity was strongly negatively correlated with BVP signal quality for TCS and FMS, and weakly for FNMS. Intraictal analysis revealed that tonic and clonic subphases have the lowest BVP signal quality and the highest ACC activity. Significance Motor elements of seizures significantly impair BVP signal quality, but do not have significant effect on EDA signal quality, as assessed by wrist‐worn wearables. The results underscore the importance of signal quality assessment methods and careful selection of robust modalities to ensure reliable seizure detection. Future research is needed to explain whether seizure detection models' decisions are based on signal responses induced by physiological processes as opposed to artifacts.
Abstract This study describes a generalized cross‐patient seizure‐forecasting approach using recurrent neural networks with ultra‐long‐term subcutaneous EEG (sqEEG) recordings. Data from six patients diagnosed with refractory epilepsy and monitored with an sqEEG device were used to develop a generalized algorithm for seizure forecasting using long short‐term memory (LSTM) deep‐learning classifiers. Electrographic seizures were identified by a board‐certified epileptologist. One‐minute data segments were labeled as preictal or interictal based on their relationship to confirmed seizures. Data were separated into training and testing data sets, and to compensate for the unbalanced data ratio in training, noise‐added copies of preictal data segments were generated to expand the training data set. The mean and standard deviation (SD) of the training data were used to normalize all data, preserving the pseudo‐prospective nature of the analysis. Different architecture classifiers were trained and tested using a leave‐one‐patient‐out cross‐validation method, and the area under the receiver‐operating characteristic (ROC) curve (AUC) was used to evaluate the performance classifiers. The importance of each input signal was evaluated using a leave‐one‐signal‐out method with repeated training and testing for each classifier. Cross‐patient classifiers achieved performance significantly better than chance in four of the six patients and an overall mean AUC of 0.602 ± 0.126 (mean ± SD). A time in warning of 37.386% ± 5.006% (mean ± std) and sensitivity of 0.691 ± 0.068 (mean ± std) were observed for patients with better than chance results. Analysis of input channels showed a significant contribution ( p < .05) by the Fourier transform of signals channels to overall classifier performance. The relative contribution of input signals varied among patients and architectures, suggesting that the inclusion of all signals contributes to robustness in a cross‐patient classifier. These early results show that it is possible to forecast seizures training with data from different patients using two‐channel ultra‐long‐term sqEEG.
Abstract Objective One of the most disabling aspects of living with chronic epilepsy is the unpredictability of seizures. Cumulative research in the past decades has advanced our understanding of the dynamics of seizure risk. Technological advances have recently made it possible to record pertinent biological signals, including electroencephalogram (EEG), continuously. We aimed to assess whether patient‐specific seizure forecasting is possible using remote, minimally invasive ultra‐long‐term subcutaneous EEG. Methods We analyzed a two‐center cohort of ultra‐long‐term subcutaneous EEG recordings, including six patients with drug‐resistant focal epilepsy monitored for 46–230 days with median 18 h/day of recorded data, totaling >11 000 h of EEG. Total electrographic seizures identified by visual review ranged from 12 to 36 per patient. Three candidate subject‐specific long short‐term memory network deep learning classifiers were trained offline and pseudoprospectively on preictal (1 h before) and interictal (>1 day from seizures) EEG segments. Performance was assessed relative to a random predictor. Periodicity of the final forecasts was also investigated with autocorrelation. Results Depending on each architecture, significant forecasting performance was achieved in three to five of six patients, with overall mean area under the receiver operating characteristic curve of .65–.74. Significant forecasts showed sensitivity ranging from 64% to 80% and time in warning from 10.9% to 44.4%. Overall, the output of the forecasts closely followed patient‐specific circadian patterns of seizure occurrence. Significance This study demonstrates proof‐of‐principle for the possibility of subject‐specific seizure forecasting using a minimally invasive subcutaneous EEG device capable of ultra‐long‐term at‐home recordings. These results are encouraging for the development of a prospective seizure forecasting trial with minimally invasive EEG.
Signal quality and power spectrum analysis of remote ultra long‐term subcutaneous EEG
Abstract Objective Ultra long‐term subcutaneous electroencephalography (sqEEG) monitoring is a new modality with great potential for both health and disease, including epileptic seizure detection and forecasting. However, little is known about the long‐term quality and consistency of the sqEEG signal, which is the objective of this study. Methods The largest multicenter cohort of sqEEG was analyzed, including 14 patients with epilepsy and 12 healthy subjects, implanted with a sqEEG device (24/7 EEG ™ SubQ), and recorded from 23 to 230 days (median 42 days), with a median data capture rate of 75% (17.9 hours/day). Median power spectral density plots of each subject were examined for physiological peaks, including at diurnal and nocturnal periods. Long‐term temporal trends in signal impedance and power spectral features were investigated with subject‐specific linear regression models and group‐level linear mixed‐effects models. Results sqEEG spectrograms showed an approximate 1/f power distribution. Diurnal peaks in the alpha range (8‐13Hz) and nocturnal peaks in the sigma range (12‐16Hz) were seen in the majority of subjects. Signal impedances remained low, and frequency band powers were highly stable throughout the recording periods. Significance The spectral characteristics of minimally invasive, ultra long‐term sqEEG are similar to scalp EEG, whereas the signal is highly stationary. Our findings reinforce the suitability of this system for chronic implantation on diverse clinical applications, from seizure detection and forecasting to brain‐computer interfaces.
Signal quality and patient experience with wearable devices for epilepsy management
Abstract Noninvasive wearable devices have great potential to aid the management of epilepsy, but these devices must have robust signal quality, and patients must be willing to wear them for long periods of time. Automated machine learning classification of wearable biosensor signals requires quantitative measures of signal quality to automatically reject poor‐quality or corrupt data segments. In this study, commercially available wearable sensors were placed on patients with epilepsy undergoing in‐hospital or in‐home electroencephalographic (EEG) monitoring, and healthy volunteers. Empatica E4 and Biovotion Everion were used to record accelerometry (ACC), photoplethysmography (PPG), and electrodermal activity (EDA). Byteflies Sensor Dots were used to record ACC and PPG, the Activinsights GENEActiv watch to record ACC, and Epitel Epilog to record EEG data. PPG and EDA signals were recorded for multiple days, then epochs of high‐quality, marginal‐quality, or poor‐quality data were visually identified by reviewers, and reviewer annotations were compared to automated signal quality measures. For ACC, the ratio of spectral power from 0.8 to 5 Hz to broadband power was used to separate good‐quality signals from noise. For EDA, the rate of amplitude change and prevalence of sharp peaks significantly differentiated between good‐quality data and noise. Spectral entropy was used to assess PPG and showed significant differences between good‐, marginal‐, and poor‐quality signals. EEG data were evaluated using methods to identify a spectral noise cutoff frequency. Patients were asked to rate the usability and comfort of each device in several categories. Patients showed a significant preference for the wrist‐worn devices, and the Empatica E4 device was preferred most often. Current wearable devices can provide high‐quality data and are acceptable for routine use, but continued development is needed to improve data quality, consistency, and management, as well as acceptability to patients.
How to record high‐frequency oscillations in epilepsy: A practical guideline
Summary Objective Technology for localizing epileptogenic brain regions plays a central role in surgical planning. Recent improvements in acquisition and electrode technology have revealed that high‐frequency oscillations ( HFO s) within the 80–500 Hz frequency range provide the neurophysiologist with new information about the extent of the epileptogenic tissue in addition to ictal and interictal lower frequency events. Nevertheless, two decades after their discovery there remain questions about HFO s as biomarkers of epileptogenic brain and there use in clinical practice. Methods In this review, we provide practical, technical guidance for epileptologists and clinical researchers on recording, evaluation, and interpretation of ripples, fast ripples, and very high‐frequency oscillations. Results We emphasize the importance of low noise recording to minimize artifacts. HFO analysis, either visual or with automatic detection methods, of high fidelity recordings can still be challenging because of various artifacts including muscle, movement, and filtering. Magnetoencephalography and intracranial electroencephalography ( iEEG) recordings are subject to the same artifacts. Significance High‐frequency oscillations are promising new biomarkers in epilepsy. This review provides interested researchers and clinicians with a review of current state of the art of recording and identification and potential challenges to clinical translation.