Back to Authors

Martins, Isabel Pavão

https://orcid.org/0000-0002-9611-7400

Mayo Clinic

University of Lisbon

Citations 4

Seizure forecasting using minimally invasive, ultra‐long‐term subcutaneous EEG: Generalizable cross‐patient models
Attia, Tal Pal , Viana, Pedro F. , Nasseri, Mona , Duun‐Henriksen, Jonas , Biondi, Andrea , Winston, Joel S. , Martins, Isabel Pavão , Nurse, Ewan S. , Dümpelmann, Matthias , Worrell, Gregory A. , Schulze‐Bonhage, Andreas , Brinkmann, Benjamin H. , Richardson, Mark P. , Pal Attia, Tal , Pavão Martins, Isabel , Freestone, Dean R , Brinkmann, Benjamin H , Richardson, Mark P , Nurse, Ewan , Schulze-Bonhage, Andreas , Dümpelmann, Matthias , Worrell, Gregory A , Duun-Henriksen, Jonas , Biondi, Andrea , Winston, Joel S , Viana, Pedro F , Freestone, Dean R. , Kjaer, Troels W

Epilepsia | April 20, 2022 | Volume: 64 | Issue: S4 | Pages: No page available

10.1111/epi.17265 Get It

Abstract This study describes a generalized cross‐patient seizure‐forecasting approach using recurrent neural networks with ultra‐long‐term subcutaneous EEG (sqEEG) recordings. Data from six patients diagnosed with refractory epilepsy and monitored with an sqEEG device were used to develop a generalized algorithm for seizure forecasting using long short‐term memory (LSTM) deep‐learning classifiers. Electrographic seizures were identified by a board‐certified epileptologist. One‐minute data segments were labeled as preictal or interictal based on their relationship to confirmed seizures. Data were separated into training and testing data sets, and to compensate for the unbalanced data ratio in training, noise‐added copies of preictal data segments were generated to expand the training data set. The mean and standard deviation (SD) of the training data were used to normalize all data, preserving the pseudo‐prospective nature of the analysis. Different architecture classifiers were trained and tested using a leave‐one‐patient‐out cross‐validation method, and the area under the receiver‐operating characteristic (ROC) curve (AUC) was used to evaluate the performance classifiers. The importance of each input signal was evaluated using a leave‐one‐signal‐out method with repeated training and testing for each classifier. Cross‐patient classifiers achieved performance significantly better than chance in four of the six patients and an overall mean AUC of 0.602 ± 0.126 (mean ± SD). A time in warning of 37.386% ± 5.006% (mean ± std) and sensitivity of 0.691 ± 0.068 (mean ± std) were observed for patients with better than chance results. Analysis of input channels showed a significant contribution ( p < .05) by the Fourier transform of signals channels to overall classifier performance. The relative contribution of input signals varied among patients and architectures, suggesting that the inclusion of all signals contributes to robustness in a cross‐patient classifier. These early results show that it is possible to forecast seizures training with data from different patients using two‐channel ultra‐long‐term sqEEG.
Seizure forecasting using minimally invasive, ultra‐long‐term subcutaneous electroencephalography: Individualized intrapatient models
Viana, Pedro F. , Attia, Tal Pal , Duun‐Henriksen, Jonas , Biondi, Andrea , Winston, Joel S. , Martins, Isabel Pavão , Nurse, Ewan S. , Dümpelmann, Matthias , Schulze‐Bonhage, Andreas , Richardson, Mark P. , Brinkmann, Benjamin H. , Pal Attia, Tal , Nasseri, Mona , Duun-Henriksen, Jonas , Biondi, Andrea , Winston, Joel S , Pavão Martins, Isabel , Nurse, Ewan , Dümpelmann, Matthias , Schulze-Bonhage, Andreas , Freestone, Dean R , Kjaer, Troels W , Richardson, Mark P , Brinkmann, Benjamin H , Viana, Pedro F , Freestone, Dean R.

Epilepsia | April 8, 2022 | Volume: 64 | Issue: S4 | Pages: No page available

10.1111/epi.17252 Get It

Abstract Objective One of the most disabling aspects of living with chronic epilepsy is the unpredictability of seizures. Cumulative research in the past decades has advanced our understanding of the dynamics of seizure risk. Technological advances have recently made it possible to record pertinent biological signals, including electroencephalogram (EEG), continuously. We aimed to assess whether patient‐specific seizure forecasting is possible using remote, minimally invasive ultra‐long‐term subcutaneous EEG. Methods We analyzed a two‐center cohort of ultra‐long‐term subcutaneous EEG recordings, including six patients with drug‐resistant focal epilepsy monitored for 46–230 days with median 18 h/day of recorded data, totaling >11 000 h of EEG. Total electrographic seizures identified by visual review ranged from 12 to 36 per patient. Three candidate subject‐specific long short‐term memory network deep learning classifiers were trained offline and pseudoprospectively on preictal (1 h before) and interictal (>1 day from seizures) EEG segments. Performance was assessed relative to a random predictor. Periodicity of the final forecasts was also investigated with autocorrelation. Results Depending on each architecture, significant forecasting performance was achieved in three to five of six patients, with overall mean area under the receiver operating characteristic curve of .65–.74. Significant forecasts showed sensitivity ranging from 64% to 80% and time in warning from 10.9% to 44.4%. Overall, the output of the forecasts closely followed patient‐specific circadian patterns of seizure occurrence. Significance This study demonstrates proof‐of‐principle for the possibility of subject‐specific seizure forecasting using a minimally invasive subcutaneous EEG device capable of ultra‐long‐term at‐home recordings. These results are encouraging for the development of a prospective seizure forecasting trial with minimally invasive EEG.
Signal quality and power spectrum analysis of remote ultra long‐term subcutaneous EEG
Viana, Pedro F. , Remvig, Line Sofie, Duun‐Henriksen, Jonas , Glasstetter, Martin , Dümpelmann, Matthias , Nurse, Ewan S. , Martins, Isabel Pavão , Schulze‐Bonhage, Andreas , Brinkmann, Benjamin H. , Richardson, Mark P. , Brinkmann, Benjamin H , Kjaer, Troels W , Nurse, Ewan , Schulze-Bonhage, Andreas , Dümpelmann, Matthias , Richardson, Mark P , Duun-Henriksen, Jonas , Pavão Martins, Isabel , Viana, Pedro F , Freestone, Dean R.

Epilepsia | July 12, 2021 | Volume: 62 | Issue: 8 | Pages: 1820-1828

10.1111/epi.16969 Get It

Abstract Objective Ultra long‐term subcutaneous electroencephalography (sqEEG) monitoring is a new modality with great potential for both health and disease, including epileptic seizure detection and forecasting. However, little is known about the long‐term quality and consistency of the sqEEG signal, which is the objective of this study. Methods The largest multicenter cohort of sqEEG was analyzed, including 14 patients with epilepsy and 12 healthy subjects, implanted with a sqEEG device (24/7 EEG ™ SubQ), and recorded from 23 to 230 days (median 42 days), with a median data capture rate of 75% (17.9 hours/day). Median power spectral density plots of each subject were examined for physiological peaks, including at diurnal and nocturnal periods. Long‐term temporal trends in signal impedance and power spectral features were investigated with subject‐specific linear regression models and group‐level linear mixed‐effects models. Results sqEEG spectrograms showed an approximate 1/f power distribution. Diurnal peaks in the alpha range (8‐13Hz) and nocturnal peaks in the sigma range (12‐16Hz) were seen in the majority of subjects. Signal impedances remained low, and frequency band powers were highly stable throughout the recording periods. Significance The spectral characteristics of minimally invasive, ultra long‐term sqEEG are similar to scalp EEG, whereas the signal is highly stationary. Our findings reinforce the suitability of this system for chronic implantation on diverse clinical applications, from seizure detection and forecasting to brain‐computer interfaces.
230 days of ultra long‐term subcutaneous EEG: seizure cycle analysis and comparison to patient diary
Viana, Pedro F. , Duun‐Henriksen, Jonas , Glasstëter, Martin, Nurse, Ewan S. , Martins, Isabel Pavão , Dumanis, Sonya B. , Schulze‐Bonhage, Andreas , Brinkmann, Benjamin H. , Richardson, Mark P. , Brinkmann, Benjamin H , Richardson, Mark P , Nurse, Ewan , Schulze-Bonhage, Andreas , Duun-Henriksen, Jonas , Pavão Martins, Isabel , Viana, Pedro F , Dümpelmann, Matthias , Freestone, Dean R.

Annals of Clinical and Translational Neurology | December 4, 2020 | Volume: 8 | Issue: 1 | Pages: 288-293

10.1002/acn3.51261 Get It

AbstractWe describe the longest period of subcutaneous EEG (sqEEG) monitoring to date, in a 35‐year‐old female with refractory epilepsy. Over 230 days, 4791/5520 h of sqEEG were recorded (86%, mean 20.8 [IQR 3.9] hours/day). Using an electronic diary, the patient reported 22 seizures, while automatically‐assisted visual sqEEG review detected 32 seizures. There was substantial agreement between days of reported and recorded seizures (Cohen’s kappa 0.664), although multiple clustered seizures remained undocumented. Circular statistics identified significant sqEEG seizure cycles at circadian (24‐hour) and multidien (5‐day) timescales. Electrographic seizure monitoring and analysis of long‐term seizure cycles are possible with this neurophysiological tool.