AbstractIntroductionA recent study reported that diffuse left ventricular (LV) fibrosis is a predictor of atrial fibrillation (AF) recurrence following catheter ablation, by measuring postcontrast cardiac T1 (an error prone metric as per the 2017 Society for Cardiovascular Magnetic Resonance consensus statement) using an inversion‐recovery pulse sequence (an error prone method in arrhythmia) in AF ablation candidates. The purpose of this study was to verify the prior study, by measuring extracellular volume (ECV) fraction (an accurate metric) using a saturation‐recovery pulse sequence (accurate method in arrhythmia).Methods and ResultsThis study examined 100 AF patients (mean age = 62 ± 11 years, 69 males and 31 females, 67 paroxysmal [pAF] and 33 persistent [peAF]) who underwent a preablation cardiovascular magnetic resonance (CMR) exam. LV ECV and left atrial (LA) and LV functional parameters were quantified using standard analysis methods. During an average follow‐up period of 457 ± 261 days with 4 ± 3 rhythm checks per patient, 72 patients maintained sinus rhythm. Between those who maintained sinus rhythm (n = 72) and those who reverted to AF (n = 28), the only clinical characteristic that was significantly different was age (60 ± 12 years vs 66 ± 9 years); for CMR metrics, neither mean LV ECV (25.1 ± 3.3% vs 24.7 ± 3.7%), native LV T1 (1093.8 ± 73.5 ms vs 1070.2 ± 115.9 ms), left ventricular ejection fraction (54.1 ± 11.2% vs 55.7 ± 7.1%), nor LA end diastolic volume/body surface area (42.4 ± 14.8 mL/m2 vs 43.4 ± 19.6 mL/m2) were significantly different (P ≥ .23). According to Cox regression tests, none of the clinical and imaging variables predict AF recurrence.ConclusionNeither LV ECV nor other CMR metrics predict recurrence of AF following catheter ablation.
Adherence to Guideline-Directed Stroke Prevention Therapy for Atrial Fibrillation Is Achievable
Background: Efforts to improve prescription of oral anticoagulation (OAC) drugs in patients with atrial fibrillation have had limited success in improving guideline adherence. Methods: We evaluated adherence to the American College of Cardiology/American Heart Association performance measures for OAC in eligible patients with a CHA 2 DS 2 -VASc score ≥2 and trends in prescription over time in the American Heart Association’s Get With The Guidelines–AFIB (atrial fibrillation) registry. Adjusted associations with in-hospital outcomes were also determined. The cohort included 33 235 patients with a CHA 2 DS 2 -VASc score ≥2 who were admitted for atrial fibrillation and were enrolled at 115 sites between January 1, 2013, and September 31, 2017. Results: The median (25th, 75th percentile) age was 73 years (65, 81 years); 51% were female; and the median (25th, 75th percentile) CHA 2 DS 2 -VASc score was 4 (3, 5). At admission, 16 206 (59.5%) of 27 221 patients with a previous diagnosis of atrial fibrillation were taking OAC agents, and OAC drug use at admission was associated with a lower adjusted odds of in-hospital ischemic stroke (odds ratio, 0.38; 95% CI, 0.24–0.59; P <0.0001). At discharge, prescription of OAC in eligible patients (no contraindications) was 93.5% (n=25 499 of 27 270). In a sensitivity analysis, when excluding only strict contraindications (4.6%, n=1497 of 32 806), OAC prescription at discharge was 80.3%. OAC prescription at discharge was higher in those aged ≤75 years, men, those with heart failure, those with previous atrial fibrillation ablation, and those with rhythm control ( P <0.0001 for all). OAC use was lowest in Hispanic patients (90.2%, P <0.0001). Prescription of OAC at discharge in eligible patients improved over time from 79.9% to 96.6% ( P <0.0001). Conclusions: Among hospitals participating in the GWTG-AFIB quality improvement program, OAC prescription at discharge in eligible guideline-indicated patients increased significantly and improved consistently over time. These data confirm that high-level adherence to guideline-recommended stroke prevention is achievable.
A Prospective Comparison of Cardiac Imaging Using Intracardiac Echocardiography With Transesophageal Echocardiography in Patients With Atrial Fibrillation
Background— The Intracardiac Echocardiography Guided Cardioversion Helps Interventional Procedures study evaluated the concordance of intracardiac echocardiography (ICE) with transesophageal echocardiography (TEE) in patients with atrial fibrillation (AF). Methods and Results— Patients with AF undergoing right heart catheterization underwent left atrium (LA) and interatrial septal (IAS) imaging by TEE and ICE. A blinded comparison of the 2 modalities was performed at a core laboratory. Ninety-five patients aged 58±12 years completed the study. The LA was profiled in all patients with both techniques, and concordance for image quality was 96%. LA appendage (LAA) imaging was achieved in 85% with ICE and 96% with TEE. There was no difference in the presence of spontaneous echo contrast between ICE and TEE during LA imaging, but there was a trend toward a greater incidence in the LAA with TEE ( P =0.109). Intracardiac thrombus was uncommonly seen (TEE, 6.9%; ICE, 5.2%). The concordance for the presence or absence of thrombus was 97% in the LA and 92% in the LAA, but the latter was detected more frequently with TEE. IAS imaging was achieved in 91% with ICE and in 97% with TEE ( P =0.177). Concordance for patent foramen ovale and atrial septal aneurysms was 100% and 96%, respectively. A negative ICE examination was associated with absence of dense echo contrast or thrombus on TEE in 86%. Conclusions— This study provides validation for the use of ICE for LA and IAS imaging. ICE imaging was less sensitive compared to TEE for LAA thrombus identification. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00281073.