Abstract 17178: Adverse Events in Endovascular Robotic Assisted Procedures
Sankaran, Naveen , Rachakonda, Sai Rakesh, Kocheril, Abraham G. , Kesavadas, Thenkurussi, Kapa, Suraj

Circulation | July 2, 2021 | Volume: 138 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.138.suppl_1.17178 Get It

Introduction: Endovascular procedures are traditionally performed for a variety of indications. However, guidewire/catheter manipulation and hazardous radiation exposure are limitations to manual interventions. Thus, significant work has been done to develop robotic approaches to therapies. These devices have FDA clearance for performing procedures like cardiac arrhythmias, angioplasty, aneurysm repair and stenting etc. With the increasing usage of robotic assistance in endovascular procedures, it is essential to understand the adverse events that may occur. This study aims to provide an understanding of adverse events with currently available robotic systems. Methods: The analysis of adverse events is performed with the FDA MAUDE (Manufacturer and User Facility Device Experience) database. MAUDE database is a collection of reports on medical devices reported by manufacturers, distributors, users, volunteers. In case of occurrence of adverse events, FDA regulations requires that event to be reported for further investigation. Based on the impact of events on the patient’s outcome, the reported events were grouped into 3 categories death (patient death), injury (patient injury) or device malfunction. Results: A total of 71 different events were reported collectively for all the four robotic devices (Hansen Medical- 37, Corindus Inc.-27, Stereotaxis Inc.-5 & Catheter Robotics Inc.-2). The major adverse events included death and common injuries such as perforation, pseudo-aneurysm / blockage/ tamponade/ clot, blood pressure dropped or an effusion, or hemodynamic instability. The table summarizes the events by brand of system. Conclusions: While robotic approaches to intervention reflect a potentially useful means to improve outcomes of endovascular procedures by optimizing catheter manipulation with finer robotic motions or limiting radiation exposure, there are potentially significant risks. Whether these reflect higher or lower risk than traditional manual approaches requires randomized studies. Use of robotic technologies may present additional risks in light of potential malfunctions that occur from system errors that a human system may not be prone to. Future studies will be needed to better understand incremental benefit.
A Prospective Comparison of Cardiac Imaging Using Intracardiac Echocardiography With Transesophageal Echocardiography in Patients With Atrial Fibrillation
Saksena, Sanjeev , Sra, Jasbír , Jordaens, Luc , Knight, Bradley P. , Kocheril, Abraham G. , Nanda, Navin C. , Nagarakanti, Rangadham , Viggiano, Mary A., Chandler, Mary L., Group, ICE-CHIP Investigator Study, Kusumoto, Fred , Natale, Andrea , Simon, Ann M. , Lokhandwala, Tasneem , Group, ICE-CHIP Investigator Study, Knight, Bradley P

Circulation: Arrhythmia and Electrophysiology | September 18, 2010 | Volume: 3 | Issue: 6 | Pages: 571-577

10.1161/circep.110.936161 Get It

Background— The Intracardiac Echocardiography Guided Cardioversion Helps Interventional Procedures study evaluated the concordance of intracardiac echocardiography (ICE) with transesophageal echocardiography (TEE) in patients with atrial fibrillation (AF). Methods and Results— Patients with AF undergoing right heart catheterization underwent left atrium (LA) and interatrial septal (IAS) imaging by TEE and ICE. A blinded comparison of the 2 modalities was performed at a core laboratory. Ninety-five patients aged 58±12 years completed the study. The LA was profiled in all patients with both techniques, and concordance for image quality was 96%. LA appendage (LAA) imaging was achieved in 85% with ICE and 96% with TEE. There was no difference in the presence of spontaneous echo contrast between ICE and TEE during LA imaging, but there was a trend toward a greater incidence in the LAA with TEE ( P =0.109). Intracardiac thrombus was uncommonly seen (TEE, 6.9%; ICE, 5.2%). The concordance for the presence or absence of thrombus was 97% in the LA and 92% in the LAA, but the latter was detected more frequently with TEE. IAS imaging was achieved in 91% with ICE and in 97% with TEE ( P =0.177). Concordance for patent foramen ovale and atrial septal aneurysms was 100% and 96%, respectively. A negative ICE examination was associated with absence of dense echo contrast or thrombus on TEE in 86%. Conclusions— This study provides validation for the use of ICE for LA and IAS imaging. ICE imaging was less sensitive compared to TEE for LAA thrombus identification. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00281073.