Back to Authors

DeSimone, Christopher V.

https://orcid.org/0000-0002-8420-4670

Mayo Clinic

Mayo Clinic

Citations 148

Abstract 16741: A Comparison of High versus Conventional Power Radiofrequency Catheter Ablation for Pulmonary Vein Isolation: A Systematic Review and Meta-Analysis
Amin, Mustapha, Nayfeh, Tarek , Nanaa, Ahmad , Saadi, Samer , Killu, Ammar M. , Madhavan, Malini , Mulpuru, Siva K. , Deshmukh, Abhishek , Nayfeh, Tarek , Saadi, Samer , Kapa, Suraj , DeSimone, Christopher V.

Circulation | November 12, 2020 | Volume: 142 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.142.suppl_3.16741 Get It

Objectives: We sought to evaluate the procedural safety and outcomes of high power (HP) versus conventional power (CP) radiofrequency (RF) ablation during pulmonary vein isolation (PVI). Methods: A systematic search was used via MEDLINE, EMBASE, and Cochrane databases between 01/1998 and 05/2020 for studies comparing the safety and efficacy between HP and CP during RF ablation for PVI using contact-force catheters (ThermocoolSmartTouch or TactiCath). The search terms used were “AF” AND “catheter ablation” OR “radiofrequency ablation”. Results: From eight comparative observational studies, we developed a cohort of 992 patients (478 in the HP and 514 in the CP group). The median maximum energy output used in the HP group was 50W vs 35W in the CP group. There was a statistically significant difference noted in acute pulmonary vein reconnection (APVR) in the HP group compared to the CP groups at16% vs 32.6%, respectively (RR: 0.53, 95% CI: 0.33 - 0.86, P = 0.01). Freedom from arrhythmia at 12 months follow-up was also significant and found to be 87.8% of cases in the HP group versus75.2% of cases in the CP group (RR: 0.46, 95%CI: 0.32 - 0.65, P <0.01). The mean RF ablation time was 20.1 minutes in the HP group vs 39.6 minutes in the CP group (P <0.01). The mean total procedural time was 103.5 minutes in the HP group compared to 135 minutes in the CP group (P <0.01). Two patients in the CP group experienced severe adverse events (1 cardiac tamponade and 1 myocardial infarction). No serious AEs were found in the HP group. Non-serious AEs (groin complications, pericardial effusion, and phrenic nerve injury) were reported in 0.35% and 0.51% of cases in the HP and CP group, respectively. Conclusion: This study suggests that HP PVI ablation can be associated with better ablation outcomes by reducing the rate of acute and late PV reconnection and atrial arrhythmia recurrence, with similar safety profiles, and shorter procedural times. These findings merit evaluation in a randomized controlled trial.
Infection Rate and Outcomes of Watchman Devices: Results from a Single Center 14-Year Experience
McGill, Trevon, Ponamgi, Shiva , Asirvatham, Samuel J. , Holmes, David , DeSimone, Christopher V. , Asirvatham, Samuel J , DeSimone, Christopher V , Ward, Robert C. , Adel, Fadi , Baddour, Larry M. , DeSimone, Daniel C.

No container title available | October 1, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.160157615.57696419 Get It

Background: Left atrial appendage occlusion with the Watchman device is an alternative strategy for stroke risk reduction in patients with non-valvular atrial fibrillation. There are rare case reports of Watchman associated infection. Currently, there is no formal study that evaluated the incidence and outcomes of Watchman-related infections. Methods: All patients who underwent Watchman implantation over a 14 year study period (July 2004 through December 2018) comprised our cohort. Baseline characteristics, procedural data, and post-implantation events were identified. Primary study outcomes included Watchman related infection, other cardiovascular device related infection, bacteremia, and mortality. Results: A total of 181 patients with an average age of 75, and a median CHA2DS2-VASc Score of 4 (interquartile range 2) and a median HAS-BLED Score of 3 (interquartile range 1), were included for analysis. A total of 534.7 patient years of follow up was accrued with an average of 2.9 years per patient. The most common indications for implantation included gastrointestinal bleeding (56 patients; 30.9%) and intracerebral bleeding (51 patients; 28.2%). During follow up, 38 patients (21%) died. Six developed evidence of bacteremia. Only one developed an implantable cardioverter defibrillator (ICD) infection that required complete system extraction. None of the cohort developed Watchman-related device infection during the study period. Conclusion: In a single center study spanning a 14 year period, we report no Watchman-related devices infections. This is despite the presence of patients with bacteremia, as well as an ICD infection requiring extraction. These data suggest that Watchman devices are extremely unlikely to become infected.
Mortality in Patients With Right Bundle‐Branch Block in the Absence of Cardiovascular Disease
Gaba, Prakriti , Pedrotty, Dawn , Bonikowske, Amanda R. , Allison, Thomas G. , Bonikowske, Amanda , DeSimone, Christopher V. , Kapa, Suraj

Journal of the American Heart Association | September 14, 2020 | Volume: 9 | Issue: 19 | Pages: No page available

10.1161/jaha.120.017430 Get It

Background Right bundle‐branch block (RBBB) occurs in 0.2% to 1.3% of people and is considered a benign finding. However, some studies have suggested increased risk of cardiovascular morbidity and mortality. We sought to evaluate risk attributable to incidental RBBB in patients without prior diagnosis of cardiovascular disease (CVD). Methods and Results We reviewed the Mayo Clinic Integrated Stress Center database for exercise stress tests performed from 1993 to 2010. Patients with no known CVD—defined as absence of coronary disease, structural heart disease, heart failure, or cerebrovascular disease—were selected. Only Minnesota residents were included, all of whom had full mortality and outcomes data. There were 22 806 patients without CVD identified; 220 of whom (0.96%) had RBBB, followed for 6 to 23 years (mean 12.4±5.1). There were 8256 women (36.2%), mean age was 52±11 years; and 1837 deaths (8.05%), including 645 cardiovascular‐related deaths (2.83%), occurred over follow‐up. RBBB was predictive of all‐cause (hazard ratio [HR], 1.5; 95% CI, 1.1–2.0; P =0.0058) and cardiovascular‐related mortality (HR,1.7; 95% CI, 1.1–2.8; P =0.0178) after adjusting for age, sex, diabetes mellitus, hypertension, obesity, current and past history of smoking, and use of a heart rate‐lowering drug. Patients with RBBB exhibited more hypertension (34.1% versus 23.7%, P <0.0003), decreased functional aerobic capacity (82±25% versus 90±24%; P <0.0001), slower heart rate recovery (13.5±11.5 versus 17.1±9.4 bpm; P <0.0001), and more dyspnea (28.2% versus 22.4%; P <0.0399) on exercise testing. Conclusions Patients with RBBB without CVD have increased risk of all‐cause mortality, cardiovascular‐related mortality, and lower exercise tolerance. These data suggest RBBB may be a marker of early CVD and merit further prospective evaluation.
Ventricular asystole in the presence of a biventricular device
Karki, Roshan , Lloyd, James W. , Mulpuru, Siva K. , Asirvatham, Samuel J. , Lloyd, James, Asirvatham, Samuel J , Lloyd, James, DeSimone, Christopher V.

Journal of Cardiovascular Electrophysiology | August 12, 2020 | Volume: 31 | Issue: 11 | Pages: 3031-3035

10.1111/jce.14715 Get It

AbstractIn pacemaker‐dependent patients with a newly implanted cardiac device, acute lead dislodgement constitutes one of the most common causes of loss of capture and ventricular asystole. In a biventricular system, it would be expected that such a potentially catastrophic event would be prevented with back‐up right ventricular pacing unless both leads dislodge.
Utilization and procedural adverse outcomes associated with Watchman device implantation
Khalil, Fouad , Arora, Shilpkumar , Killu, Ammar M. , Egbe, Alexander C. , Kapa, Suraj , Mulpuru, Siva K. , Mohamad, Alkhouli, Friedman, Paul A. , Holmes, David R. , Deshmukh, Abhishek , Mulpuru, Siva, Khalil, Fouad , Kapa, Suraj , Tripathi, Byomesh , DeSimone, Christopher V. , Noseworthy, Peter A. , Gersh, Bernard J.

EP Europace | August 9, 2020 | Volume: 23 | Issue: 2 | Pages: 247-253

10.1093/europace/euaa219 Get It

AbstractAims The Food and Drug Administration (FDA) approval of the Watchman device [percutaneous left atrial appendage occlusion (LAAO)] has resulted in the widespread use of this procedure in many centres across the USA. We sought to estimate the nationwide utilization and frequency of adverse outcomes associated with Watchman device implantation. The objective of this study was to evaluate the Watchman device implantation peri-procedural complications and comparison of the results with the previous studies.Methods and results The National Inpatient Sample (NIS) was queried for all hospitalizations with a primary diagnosis of atrial fibrillation or atrial flutter during the year 2016 with percutaneous LAAO during the same admission (ICD-10 code—02L73DK). The frequency of peri-procedural complications, including mortality, procedure-related stroke, major bleeding requiring blood transfusion, and pericardial effusion, was assessed. We compared the complication rates with the published randomized controlled trials and the European Watchman registry. An estimated 5175 LAAO procedures were performed in 2016. The majority of procedures was performed in males (59.1%), age ≥75 years (58.7%), and White (83.1%). The overall complication rate was 1.9%. The in-hospital mortality was 0.29%. Pericardial effusion requiring pericardiocentesis was the most frequent complication (0.68%). Bleeding requiring transfusion was noted in 0.1% of device implants. The rates of post-procedure stroke and systemic embolism were 0% and 0.29%, respectively.Conclusion Percutaneous LAAO with the Watchman device in the USA is associated with low in-hospital complications and a similar safety profile to a recently published EWOLUTION cohort. The complication rates were lower than those reported in the major randomized clinical trials (RCTs). We report the frequency of peri-procedural complications of the LAAO using the Watchman device from the NIS database. We also compare the frequency of peri-procedural complications with the previously published RCTs and EWOLUTION cohort. Our findings are in concordance with findings from EWOLUTION cohort and compare favourably with RCTs.
High Mortality Rates Among Patients With Non‐Traumatic Intracerebral Hemorrhage and Atrial Fibrillation on Antithrombotic Therapy Are Independent of the Presence of Cerebral Amyloid Angiopathy: Insights From a Population‐Based Study
Ponamgi, Shiva , English, Stephen , Hodge, David O. , Slusser, Joshua P. , Graff‐Radford, Jonathan , Asirvatham, Samuel J. , Holmes, David R. , Ponamgi, Shiva P , Ward, Robert, Asirvatham, Samuel J , Ward, Robert C. , DeSimone, Christopher V. , Rabinstein, Alejandro A.

Journal of the American Heart Association | July 25, 2020 | Volume: 9 | Issue: 15 | Pages: No page available

10.1161/jaha.120.016893 Get It

Background Intracerebral hemorrhage (ICH) risk is higher in elderly patients with atrial fibrillation on antithrombotic therapy as well as those with cerebral amyloid angiopathy (CAA). We investigated if mortality among patients with atrial fibrillation on antithrombotic therapy presenting with non‐traumatic ICH was influenced by underlying CAA. Methods and Results We used the Rochester Epidemiology Project to identify 6045 patients with atrial fibrillation aged >55 years on anticoagulation or antiplatelet therapy from 1995 to 2016. Seventy‐four patients in this cohort presented with non‐traumatic ICH. Medical records including imaging data were reviewed to identify those with CAA and record baseline variables and outcomes of interest; 38 of our 74 patients (51.4%) (mean age 81.5 years) met Modified Boston Criteria for possible or probable CAA. Twenty‐six of 74 patients (35%) died during the first 30 days while 56 of the 74 (76%) patients died by 10 years follow‐up after index ICH. Overall mortality was not significantly different between the CAA and non‐CAA groups at any point of time during follow‐up ( P =0.89) even amongst patients restarted on anticoagulation +/− antiplatelet (n=19) ( P =0.46) or those patients restarted only on antiplatelet therapy (n=22) ( P =0.66). Three of the 41 patients who restarted on antithrombotic therapy had a recurrent ICH; these 3 patients met criteria for possible or probable CAA. Conclusions Although more than half of our patients with atrial fibrillation on antithrombotic therapy and non‐traumatic ICH met Modified Boston Criteria for CAA, CAA did not significantly influence the high mortality seen in this cohort.
Burden of Arrhythmia in Hospitalized HIV Patients
Abudan, Anas , Vaidya, Vaibhav, Tripathi, Byomesh , Egbe, Alexander , Arora, Shilpkumar , Sridhar, Haarini , DeSimone, Christopher V. , Mulpuru, Siva K. , Deshmukh, Abhishek , DeSimone, Christopher V , Noseworthy, Peter A. , DeSimone, Daniel C.

No container title available | July 16, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.159493215.58844465 Get It

Background: The improved life expectancy observed in patients living with Human Immunodeficiency Virus (HIV) infection has made age-related cardiovascular complications, including arrhythmias, a growing health concern. We describe the temporal trends in frequency of various arrhythmias and assess impact of arrhythmias on hospitalized HIV patients using the Nationwide Inpatient Sample (NIS) Methods and Results: Data on HIV-related hospitalizations from 2005 to 2014 were obtained from the NIS using International Classification of Diseases, 9th Revision (ICD-9) codes. Data was further subclassified into hospitalizations with associated arrhythmias and those without arrhythmia. Baseline demographics and comorbidities were determined. Outcomes including in-hospital mortality, cost of care, and length of stay were extracted. SAS 9.4 (SAS Institute Inc., Cary, North Carolina) was utilized for analysis. A multivariable analysis was performed to identify predictors of arrhythmias among hospitalized HIV patients. Among 2,370,751 HIV-related hospitalizations identified, the overall frequency of any arrhythmia was 3.01%. Atrial fibrillation (AF) was the most frequent arrhythmia (2110 per 100,000). The overall frequency of arrhythmias has increased over time by 108%, primarily due to a 132% increase in AF. Arrhythmias are more frequent among older males, lowest income quartile and non-elective admissions. Patients with arrhythmias had a higher in-hospital mortality rate (9.6%). In-hospital mortality among patients with arrhythmias has decreased over time by 43.8%. The cost of care and length of stay associated with arrhythmia-related hospitalizations were mostly unchanged. Conclusions: Arrhythmias are associated with significant morbidity and mortality in hospitalized HIV patients. AF is the most frequent arrhythmia in hospitalized HIV patients.
Wide Complex Tachycardia Differentiation: A Reappraisal of the State‐of‐the‐Art
Kashou, Anthony H. , Deshmukh, Abhishek , Asirvatham, Samuel J. , May, Adam M. , Asirvatham, Samuel J , May, Adam M , Noseworthy, Peter A. , DeSimone, Christopher V.

Journal of the American Heart Association | May 19, 2020 | Volume: 9 | Issue: 11 | Pages: No page available

10.1161/jaha.120.016598 Get It

Abstract The primary goal of the initial ECG evaluation of every wide complex tachycardia is to determine whether the tachyarrhythmia has a ventricular or supraventricular origin. The answer to this question drives immediate patient care decisions, ensuing clinical workup, and long‐term management strategies. Thus, the importance of arriving at the correct diagnosis cannot be understated and has naturally spurred rigorous research, which has brought forth an ever‐expanding abundance of manually applied and automated methods to differentiate wide complex tachycardias. In this review, we provide an in‐depth analysis of traditional and more contemporary methods to differentiate ventricular tachycardia and supraventricular wide complex tachycardia. In doing so, we: (1) review hallmark wide complex tachycardia differentiation criteria, (2) examine the conceptual and structural design of standard wide complex tachycardia differentiation methods, (3) discuss practical limitations of manually applied ECG interpretation approaches, and (4) highlight recently formulated methods designed to differentiate ventricular tachycardia and supraventricular wide complex tachycardia automatically.
The VT Prediction Model: A simplified means to differentiate wide complex tachycardias
May, Adam M. , Kashou, Anthony H. , Sridhar, Haarini , Hodge, David O. , Carter, Rickey E. , Lin, Grace , Asirvatham, Samuel J. , Noseworthy, Peter A. , Deshmukh, Abhishek , Carter, Rickey, Asirvatham, Samuel J , Noseworthy, Peter A , Deshmukh, Abhishek J , Carter, Rickey E , May, Adam M , DeSimone, Christopher V.

Journal of Cardiovascular Electrophysiology | December 16, 2019 | Volume: 31 | Issue: 1 | Pages: 185-195

10.1111/jce.14321 Get It

AbstractBackgroundThe accurate separation of undifferentiated wide complex tachycardias (WCTs) into ventricular tachycardia (VT) or supraventricular wide complex tachycardia (SWCT) using conventional, manually‐applied 12‐lead electrocardiogram (ECG) interpretation methods is difficult.PurposeWe sought to devise a new WCT differentiation method that operates solely on automated measurements routinely provided by computerized ECG interpretation software.MethodsIn a two‐part analysis, we developed and validated a logistic regression model (ie, VT Prediction Model) that utilizes routinely available computerized measurements derived from patients' paired WCT and baseline ECGs.ResultsThe derivation cohort consisted of 601 paired WCT (273 VT, 328 SWCT) and baseline ECGs from 421 patients. The VT Prediction Model, composed of WCT QRS duration (ms) (P < .0001), QRS duration change (ms) (P < .0001), QRS axis change (°) (P < .0001) and T axis change (°) (P < .0001), yielded effective VT and SWCT differentiation (area under the curve [AUC]: 0.924; confidence interval [CI]: 0.903‐0.944) for the derivation cohort. The validation cohort comprised 241 paired WCT (97 VT, 144 SWCT) and baseline ECGs from 177 patients. The VT Prediction Model's implementation on the validation cohort yielded effective WCT differentiation (AUC: 0.900; CI: 0.862‐0.939) with overall accuracy, sensitivity, and specificity of 85.0%, 80.4%, and 88.2%, respectively.ConclusionThe VT Prediction Model is an example of how readily available ECG measurements may be used to distinguish VT and SWCT effectively. Further study is needed to develop and refine newer WCT differentiation approaches that utilize computerized measurements provided by ECG interpretation software.
Contemporary Management of Antiplatelet and Anticoagulation for Cardiac Implantable Device Procedures
Cha, Yong‐Mei , DeSimone, Christopher V. , DeSimone, Daniel C.

Circulation: Arrhythmia and Electrophysiology | October 15, 2019 | Volume: 12 | Issue: 10 | Pages: No page available

10.1161/circep.119.007863 Get It