Back to Authors

Asirvatham, Samuel J

0000-0001-9835-5536

Mayo Clinic

Department of Cardiovascular Medicine, Mayo Clinic, Rochester (K.Q.A., J.A.T., I.U.H., A.W., H.N., A.B., S.Y., R.W., F.E., N.Y.T., F.D.-C.M., S.A., C.V.D.).

Citations 269

Wobble
Asirvatham, Samuel J. , Stevenson, William G. , Asirvatham, Samuel J

Circulation: Arrhythmia and Electrophysiology | August 18, 2015 | Volume: 8 | Issue: 4 | Pages: 985-987

10.1161/circep.115.002998 Get It

The Knot That Binds Mitral Valve Prolapse and Sudden Cardiac Death
Asirvatham, Samuel J. , Noseworthy, Peter A. , Asirvatham, Samuel J

Circulation | July 9, 2015 | Volume: 132 | Issue: 7 | Pages: 551-552

10.1161/circulationaha.115.017979 Get It

Editor’s Choice-Clinical impact of delirium and antipsychotic therapy: 10-Year experience from a referral coronary care unit
Naksuk, Niyada , Park, Jae Y, Sharma, Sunita, Gaba, Prakriti , Rosenbaum, Andrew , Peeraphatdit, Thoetchai , Hu, Tiffany , Bell, Malcolm R. , Herasevich, Vitaly , Brady, Peter A. , Asirvatham, Samuel J. , Rosenbaum, Andrew N , Hu, Tiffany Y, Kapa, Suraj , Thongprayoon, Charat , Asirvatham, Samuel J , Herasevich, Vitaly

European Heart Journal: Acute Cardiovascular Care | June 30, 2015 | Volume: 6 | Issue: 6 | Pages: 560-568

10.1177/2048872615592232 Get It

Atrioventricular Nodal Block With Atrioventricular Nodal Reentrant Tachycardia Ablation
Asirvatham, Samuel J. , Stevenson, William G. , Asirvatham, Samuel J

Circulation: Arrhythmia and Electrophysiology | June 16, 2015 | Volume: 8 | Issue: 3 | Pages: 745-747

10.1161/circep.115.002989 Get It

Direct Pulmonary Vein Ablation With Stenosis Prevention Therapy
Holmes, David R. , Ebrille, Elisa , Syed, Faisal F. , Ladewig, Dorothy J., Mikell, Susan B. , Powers, Joanne, Suddendorf, Scott H., Gilles, Emily J., Danielsen, Andrew J., Hodge, David O. , Asirvatham, Samuel J. , Kapa, Suraj , DeSimone, Christopher V. , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | June 15, 2015 | Volume: 26 | Issue: 9 | Pages: 1000-1006

10.1111/jce.12732 Get It

Direct Pulmonary Vein Ablation With Stenosis Prevention TherapyIntroductionThe dominant location of electrical triggers for initiating atrial fibrillation (AF) originates from the muscle sleeves inside pulmonary veins (PVs). Currently, radiofrequency ablation (RFA) is performed outside of the PVs to isolate, rather than directly ablate these tissues, due to the risk of intraluminal PV stenosis.MethodsIn 4 chronic canine experiments, we performed direct PV muscle sleeve RFA ± postablation drug‐coated balloon (DCB) treatment with paclitaxel/everolimus. Of the 4 PVs, 2 PVs were ablated and treated with DCB, 1 PV was ablated without DCB treatment (positive control), and 1 PV was left as a negative control. Local electrograms were assessed in PVs for near‐field signals and were targeted for ablation. After 12–14 weeks survival, PVs were interrogated for absence of near‐field PV potentials, and each PV was assessed for stenosis.ResultsAll canines survived the study period without cardiorespiratory complications, and remained ambulatory. In all canines, PVs that were ablated and treated with DCB remained without any significant intraluminal stenosis. In contrast, PVs that were ablated and not treated with DCB showed near or complete intraluminal stenosis. At terminal study, PV potentials remained undetectable. A blinded, histologic analysis demonstrated that ablated PVs without DCB treatment had extensive thrombus, fibrin, mineralization, and elastin disruption.ConclusionOur chronic canine data suggest that direct PV tissue ablation without subsequent stenosis is feasible with the use of postablation DCBs.
Transcatheter tricuspid valve‐in‐valve in patients with transvalvular device leads
Eleid, Mackram F. , Asirvatham, Samuel J. , Hagler, Donald J. , Taggart, Nathaniel W. , Rihal, Charanjit S. , Cabalka, Allison K. , Noseworthy, Peter A. , Rihal, Charanjit S. , Asirvatham, Samuel J , Taggart, Nathaniel W

Catheterization and Cardiovascular Interventions | May 6, 2015 | Volume: 87 | Issue: 4 | Pages: No page available

10.1002/ccd.25990 Get It

ObjectiveTo describe the effects of percutaneously implanted valve‐in‐valve in the tricuspid position for patients with pre‐existing transvalvular device leads.MethodsIn this case series, we describe implantation of the Melody valve and SAPIEN XT valve within dysfunctional bioprosthetic tricuspid valves in three patients with transvalvular device leads.ResultsIn all cases, the valve was successfully deployed and device lead function remained unchanged. In 1/3 cases with 6‐month follow‐up, device lead parameters remain unchanged and transcatheter valve‐in‐valve function remains satisfactory.ConclusionsTranscatheter tricuspid valve‐in‐valve is feasible in patients with pre‐existing transvalvular devices leads. Further study is required to determine the long‐term clinical implications of this treatment approach. © 2015 Wiley Periodicals, Inc.
Location
Asirvatham, Samuel J. , Stevenson, William G. , Asirvatham, Samuel J

Circulation: Arrhythmia and Electrophysiology | April 21, 2015 | Volume: 8 | Issue: 2 | Pages: 502-504

10.1161/circep.115.002642 Get It

Endomyocardial biopsy-integrating electrode at the bioptome tip
Konečný, Tomáš , Cooper, Leslie T. , Mulpuru, Siva K. , Sandhu, Gurpreet S. , Asirvatham, Samuel J. , Kapa, Suraj , Noseworthy, Peter A. , Asirvatham, Samuel J , Cooper, Leslie T

Therapeutic Advances in Cardiovascular Disease | March 2, 2015 | Volume: 9 | Issue: 3 | Pages: 66-69

10.1177/1753944715574660 Get It

Background: The addition of electroanatomic mapping to a standard echo-guided endomyocardial biopsy could identify areas of abnormal pathology and increase the diagnostic yield of the procedure. Methods and results: In this demonstration of a novel technique, a 45-year-old woman with clinical suspicion for cardiac sarcoidosis underwent right ventricular bipolar electroanatomical mapping with identification of areas of signal fractionation and low voltage. A bioptome, configured to record an electrogram from the tip, was then visualized on the three-dimensional electroanatomic mapping (3DEAM) system, and directed to these areas. The biopsy was assisted by the use of a steerable introducer sheath, and by recording unipolar and extended bipolar signals from the bioptome tip. A prominent change in the signal was detected by the electrode at the bioptome tip when the jaws closed on the endomyocardial tissue. Patient tolerated the procedure without complications, and the biopsied samples were appropriate for pathological analysis. Conclusions: Using existing technology, the 3DEAM, which integrates unipolar and bipolar signal from the bioptome tip, is feasible, and can be safely added to a standard echocardiographically guided endomyocardial biopsy. Future studies should investigate whether such a technique could increase the safety and diagnostic yield of endomyocardial biopsies in patients with suspected cardiomyopathies.
Taking the Slower Pathway
Asirvatham, Samuel J. , Stevenson, William G. , Asirvatham, Samuel J

Circulation: Arrhythmia and Electrophysiology | February 17, 2015 | Volume: 8 | Issue: 1 | Pages: 236-238

10.1161/circep.115.002641 Get It

Troubleshooting Implantable Cardioverter-Defibrillator Sensing Problems II
Swerdlow, Charles D. , Asirvatham, Samuel J. , Ellenbogen, Kenneth A. , Friedman, Paul A. , Asirvatham, Samuel J , Ellenbogen, Kenneth A

Circulation: Arrhythmia and Electrophysiology | February 17, 2015 | Volume: 8 | Issue: 1 | Pages: 212-220

10.1161/circep.114.002514 Get It