The spiked-helmet sign (SHS) is an electrocardiographic finding characterised by a distinctive pattern associated with critical illness, resolving once the clinical condition improves. While the underlying mechanism remains uncertain, different mechanisms have been proposed to account for these findings including changes in intrathoracic or intra-abdominal pressures, transient compression of the coronary arteries, repolarisation abnormalities and electromechanical artefacts. We describe the development of the SHS in a patient with underlying left bundle branch pacing following the development of respiratory failure due to haemoptysis and review proposed mechanisms for its pathophysiology.
Catheter ablation of atrial fibrillation in patients with and without hypertrophic cardiomyopathy: systematic review and meta-analysis
Abstract Background Atrial fibrillation (AF) is common in hypertrophic cardiomyopathy (HCM). There is limited data regarding the outcomes of AF catheter ablation in HCM patients. In this study, we aimed to synthesize all available evidence on the effectiveness of ablation of AF in patients with HCM compared to those without HCM. Methods and results We systematically reviewed bibliographic databases to identify studies published through February 2023. We included cohort studies with available quantitative information on rates of recurrent atrial arrhythmias, anti-arrhythmic drug (AAD) therapy, and repeat ablation procedures after initial AF ablation in patients with vs without HCM. Estimates were combined using random-effects meta-analysis models and reported as risk ratios (RR) and 95% confidence intervals (CI). Eight studies were included in quantitative synthesis (262 HCM and 642 non-HCM patients). During median follow-up 13–54 months across studies, AF recurrence rates ranged from 13.3% to 92.9% in HCM and 7.6% to 58.8% in non-HCM patients. The pooled RR for recurrent atrial arrhythmia after the first AF ablation in HCM patients compared to non-HCM controls was 1.498 (95% CI = 1.305–1.720; P < 0.001). During follow-up, HCM patients more often required AAD therapy (RR = 2.844; 95% CI = 1.713–4.856; P < 0.001) and repeat AF ablation (RR = 1.544; 95% CI = 1.070–2.228; P = 0.02). The pooled RR for recurrent atrial arrhythmias after the last AF ablation was higher in patients with HCM than those without HCM (RR = 1.607; 95% CI = 1.235–2.090; P < 0.001). Conclusions Compared to non-HCM patients, those with HCM had higher rates of recurrent atrial arrhythmias, AAD use, and need for repeat AF ablation after initial ablation of AF.
Impact of CIED Field Advisories: Unreimbursed Costs to Medical Systems
AbstractIntroductionData regarding ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation in patients with aortic valve (AV) intervention (AVI) is limited. Catheter ablation (CA) can be challenging given perivalvular substrate in the setting of prosthetic valves. We sought to investigate the characteristics, safety, and outcomes of CA in patients with prior AVI and ventricular arrhythmias (VA).MethodsWe identified consecutive patients with prior AVI (replacement or repair) who underwent CA for VT or PVC between 2013 and 2018. We investigated the mechanism of arrhythmia, ablation approach, perioperative complications, and outcomes.ResultsWe included 34 patients (88% men, mean age 64 ± 10.4 years, left ventricular (LV) ejection fraction 35.2 ± 15.0%) with prior AVI who underwent CA (22 VT; 12 PVC). LV access was obtained through trans‐septal approach in all patients except one patient who had percutaneous transapical access. One patient had combined retrograde aortic and trans‐septal approach. Scar‐related reentry was the dominant mechanism of induced VTs. Two patients had bundle branch reentry VTs. In the VT group, substrate mapping demonstrated heterogeneous scar that involved the peri‐AV area in 95%. Despite that, the site of successful ablation included the periaortic region only in 6 (27%) patients. In the PVC group, signal abnormalities consistent with scar in the periaortic area were noted in 4 (33%) patients. In 8 (67%) patients, the successful site of ablation was unrelated to the periaortic area. No procedure‐related complications occurred. The survival and recurrence‐free survival rate at 1 year tended to be lower in VT group than in PVC group (p = .06 and p = .05, respectively) with a 1‐year recurrence‐free survival rate of 52.8% and 91.7%, respectively. No arrhythmia‐related death was documented on long‐term follow‐up.ConclusionCA of VAs can be performed safely and effectively in patients with prior AVI.
Effects of Pulsed Electric Fields on the Coronary Arteries in Swine
Background: Previous animal studies have shown no significant vascular injury from pulsed electrical field (PEF) ablation. We sought to assess the effect of PEF on swine coronary arteries. Methods: We performed intracoronary and epicardial (near the coronary artery) PEF ablations in swine pretreated with dual antiplatelet and antiarrhythmic therapy. Intracoronary PEF was delivered using MapiT catheters (Biotronik, Berlin), whereas epicardial PEF was delivered using EPT catheters (Boston Scientific, MA). PEF pulse duration was microseconds (Nanoknife 3.0, Angio Dynamics, NY) or nanoseconds (CellFX, Pulse Biosciences, CA). Results: We performed 39 intracoronary ablations in 10 swine and 20 epicardial-pericoronary ablations in 4 separate swine. Intracoronary PEF was delivered at higher energy compared with epicardial PEF (46 [interquartile range, IQR 20–85] J versus 10 [IQR 10–11] J, P < 0.01). Reversible coronary spasm occurred in 49% intracoronary ablations and 45% epicardial ablations ( P =0.80). At the end study, fixed coronary stenosis was demonstrated in 44% intracoronary ablations (80% for microsecond PEF and 18% for nanosecond PEF) and 0% epicardial ablations. Visible hemorrhagic and/or fibrotic myocardial lesions were observed at necropsy with similar frequency between intracoronary and epicardial PEF (45% versus 50%, P =0.70). Nanosecond PEF (49 ablations in 11 swine), when compared with microsecond PEF (10 intracoronary ablations in 3 swine), resulted in lower energy delivery (21 [IQR 10–46] J versus 129 [IQR 24–143] J, P =0.03) and less incidence of fixed coronary stenosis (18% versus 80%, P =0.04). Conclusions: In the swine model, intracoronary PEF resulted both in significant coronary spasm and fixed coronary stenosis. Epicardial PEF, delivered at lower energy, resulted in reversible spasm but no fixed coronary stenosis.
Substrate Characterization and Outcomes of Catheter Ablation of Ventricular Arrhythmias in Patients With Mitral Annular Disjunction
Background: Mitral annular disjunction (MAD) has recently been recognized as an arrhythmogenic entity. Data on the electrophysiological substrate as well as the outcomes of catheter ablation of ventricular arrhythmias in patients with MAD is limited. Methods: Forty patients with MAD (mean age 47±15 years; 70% female) underwent catheter ablation for ventricular arrhythmias. Detailed clinical, electrocardiographic, cardiac imaging, and procedural data were collected. Clinical outcomes were compared between patients who had substrate modification in the MAD area and those who did not. Results: Twenty-three (57.5%) patients had ablation for premature ventricular contractions, 10 (25%) patients for sustained ventricular tachycardia, and 7 (17.5%) patients for premature ventricular contraction-triggered ventricular fibrillation. Mean end-systolic MAD length was 10.58±3.49 mm on transthoracic echocardiography. Seventeen (42.5%) patients had preprocedural cardiac magnetic resonance imaging, and 5 (29%) patients had late gadolinium enhancement. Among the 18 (45%) patients who had abnormal local electrograms (low voltage, long-duration, fractionated, isolated mid-diastolic potentials) during electroanatomical mapping, 10 (25%) patients had abnormal electrograms in the anterolateral mitral annulus and/or MAD area. Substrate modification was performed in 10 (25%) patients. Catheter ablation was acutely successful in 36 (90%) patients (elimination of premature ventricular contraction or noninducibility of ventricular tachycardia). After a median follow-up duration of 54.08 (interquartile range, 10.67–89.79) months, premature ventricular contraction burden decreased from a median of 9.75% (interquartile range, 3.25–14) before the ablation to a median of 4% (interquartile range, 1–7.75) after the ablation ( P =0.03 [95% CI, 0.055–6.5]). Eight (20.5%) patients had repeat ablation for ventricular arrhythmias. Substrate modification of the MAD was associated with a trend toward lower rates of repeat ablation (0% versus 26.7%; P =0.16). Conclusions: Patients with MAD have a complex arrhythmogenic substrate, and catheter ablation is effective in reducing recurrence of ventricular arrhythmias. Substrate mapping and ablation may be considered in these patients.
Cardiac ablation with pulsed electric fields: principles and biophysics
Abstract Pulsed electric fields (PEFs) have emerged as an ideal cardiac ablation modality. At present numerous clinical trials in humans are exploring PEF as an ablation strategy for both atrial and ventricular arrhythmias, with early data showing significant promise. As this is a relatively new technology there is limited understanding of its principles and biophysics. Importantly, PEF biophysics and principles are starkly different to current energy modalities (radiofrequency and cryoballoon). Given the relatively novel nature of PEFs, this review aims to provide an understanding of the principles and biophysics of PEF ablation. The goal is to enhance academic research and ultimately enable optimization of ablation parameters to maximize procedure success and minimize risk.
Regional and Temporal Variation of Ventricular and Conduction Tissue Activity During Ventricular Fibrillation in Canines
Background: Rigorous study of ventricular fibrillation (VF) is not feasible in humans. The spatiotemporal characteristics of prolonged VF remain undefined, limiting our understanding of this lethal rhythm. Methods: VF was mapped in 4 canines. The endocardial and epicardial left ventricle (LV) and right ventricle (RV) were sequentially mapped at 0 to 15, 15 to 30, 30 to 45, and 45 to 60 minutes post-induction. Ten consecutive beats were used to determine the average cycle length and regularity index of ventricular and His-Purkinje system signals in discrete regions during each time interval. Results: Average VF time was 58±12 minutes. The shortest ventricular cycle length was present in the RV apical region (70±10 msec) at 0 to 15 minutes and at 15 to 30 minutes (89±31 msec) and LV apical region at 45 to 60 minutes (242±163 msec). The His-Purkinje system cycle length was the shortest at the RV outflow tract (75±3 msec) at 0 to 15 minutes, RV inflow and free wall (89±12 msec) at 15 to 30 minutes, LV apical region (83±14 msec) at 30 to 45 minutes, and inferior and inferolateral LV (145±23 msec) at 45 to 60 minutes. Regularity index was the highest in the RV inflow and free wall (78%) at 0 to 15 minutes, RV apical region (86%) at 15 to 30 minutes, LV septum and epicardial anterior RV (80%) at 30 to 45 minutes, and anterior and anterolateral LV (75%) at 45 to 60 minutes. Conclusions: These data suggest significant regional changes in electrical activity throughout VF in canines. A transition of fastest electrical activity from RV to LV apical regions across VF was observed. These novel insights of the temporal and spatial changes of VF merit further evaluation in diseased hearts to assess for reproducibility of findings.
Massive Discordant T-Wave Alternans and Imminent Torsades de Pointes