Back to Authors

Morrey, B.F.

https://orcid.org/0000-0003-0234-0212

Mayo Clinic

Mayo Clinic

Citations 54

Objective Technique for Evaluating Painful Heel Syndrome and Its Treatment
Katoh, Yuki , Chao, Edmund Y.S., Morrey, B.F. , Laughman, R. Keith

Foot & Ankle | March 3, 2013 | Volume: 3 | Issue: 4 | Pages: 227-236

10.1177/107110078300300410 Get It

The biomechanical evaluation of patients with painful heels has received only limited attention although the potential morbidity and disability associated with such an ailment can be severe. An objective analysis of the patient's foot function during gait can produce useful information to assess the underlying pathology. This method can also help to evaluate the efficacy of various existing treatment protocols. The impulse distribution based on foot-floor vertical reaction force and time under the hind-, mid-, and forefoot was determined in 32 normal subjects while walking in their usual street shoes. Variations related to shoe types were noted, with high heeled shoes causing the most significant deviations from normal. The same technique was applied to 13 painful heel syndrome patients. Characteristic deviations from the normal impulse distribution were noted in these patients which provided the basis for differentiating the pathological condition between the patients with painful heel pads and those with plantar fasciitis. The effectiveness of using heel cups as a therapeutic device was also assessed. Although significant gait changes were not associated with the insertion of heel cups, they did seem to shift the foot-floor impulse forward from the heel region, which made them effective in patients afflicted with localized heel pain, but not in those with plantar fasciitis.
Fasciotomy and Surgical Tenotomy for Recalcitrant Lateral Elbow Tendinopathy
Mohan, P.C., Howe, Tet Sen , Chia, Shi‐Lu, Yang, Zixian , Morrey, B.F. , Koh, Joyce Suang Bee , Mohan, P.C., Lee, Brian P.

The American Journal of Sports Medicine | January 10, 2013 | Volume: 41 | Issue: 3 | Pages: 636-644

10.1177/0363546512470625 Get It

Background: The optimal choice for intervention for recalcitrant lateral elbow tendinopathy remains unclear as various treatment modalities have documented comparable results in the literature. Purpose: To explore the safety, tolerability, and early efficacy of a new minimally invasive mode of treatment that delivers focused, calibrated ultrasonic energy, effectively microresecting the pathological tendon and removing only pathological tissue. Study Design: Case series; Level of evidence, 4. Methods: Seven male and 13 female patients aged 33 to 65 years averaging 12.5 months (range, 4-48) of failed nonoperative therapy underwent the ultrasonic microresection procedure in an outpatient clinic setting. The procedure involved a sterile, ultrasound-guided percutaneous microresection with a proprietary device (TX1) performed through a stab incision under local anesthesia. The duration of the procedure and complications of the device or procedure were assessed. Outcome parameters included patient satisfaction; visual analog scale (VAS) pain scores; Disabilities of the Arm, Shoulder and Hand (DASH) scores at 1, 3, 6, and 12 months; and ultrasound assessment at 3 and 6 months. Results: The median duration for the sterile confirmatory ultrasound examination (phase 1) was 88.5 seconds (range, 39-211; SD, ±47.6), the median duration of the procedure proper (phase 2) was 10.1 minutes (range, 4.1-19.4; SD, ±3.7), and the median energy time (duration the TX1 device was activated) was 32.5 seconds (range, 18-58; SD, ±11.0). No complications were encountered. A significant improvement in VAS score (from 5.5 to 3.3; P < .001) occurred by 1 week, and significant improvements in both DASH-Compulsory (from 21.7 to 11.3; P = .001) and DASH-Work (from 25.0 to 6.3; P = .012) scores occurred by 1 month. The VAS scores further improved at 3, 6, and 12 months (from 2.0 to 1.0 to 0.50; P = .003 and .023). The DASH-Compulsory score improved significantly from 3 to 6 months (from 8.6 to 4.6; P = .003), and both the DASH-Compulsory and DASH-Work scores were sustained by 12 months. Sonographically reduced tendon thickness (19 patients), resolved or reduced hypervascularity (17 patients), and reduced hypoechoic area (18 patients) occurred by 6 months. Nineteen of the 20 patients (95%) expressed satisfaction with the procedure, with 9 patients being very satisfied with their overall experience at 6 months after the procedure, 10 patients somewhat satisfied, and 1 patient neutral. Conclusion: Ultrasonic microresection of diseased tissue with the TX1 device provides a focally directed, safe, specific, minimally invasive, and well-tolerated treatment for recalcitrant lateral elbow tendinopathy in an office-based or ambulatory surgical setting with good evidence of some level of efficacy in 19 of 20 patients (95%) that is sustained for at least 1 year.
Elbow Resection for Deep Infection After Total Elbow Arthroplasty
Sotelo, Joaquín Sánchez, Zarkadas, Peter C., Throckmorton, Thomas, Morrey, B.F.

JBJS Essential Surgical Techniques | November 15, 2012 | Volume: 2 | Issue: 1 | Pages: e5

10.2106/jbjs.st.k.00017 Get It

Revision of total elbow replacement by exchange cementing
Malone, Alex A., Sanchez, Jordi Sanchez, Adams, Robert , Morrey, B.F.

The Journal of Bone and Joint Surgery. British volume | January 4, 2012 | Volume: 94-B | Issue: 1 | Pages: 80-85

10.1302/0301-620x.94b1.26004 Get It

We report the effectiveness of revision of total elbow replacement by re-cementing. Between 1982 and 2004, 53 elbows in 52 patients were treated with re-cementing of a total elbow replacement into part or all of the existing cement mantle or into the debrided host-bone interface, without the use of structural bone augmentation or a custom prosthesis. The original implant revision was still in situ and functional in 42 of 53 elbows (79%) at a mean of 94.5 months (26 to 266) after surgery. In 31 of these 42 elbows (74%) the Mayo Elbow Performance Score was good or excellent. Overall, of the 53 elbows, 18 (34%) required re-operation, ten (19%) for loosening. A classification system was developed to identify those not suitable for revision by this technique, and using this we have showed that successful re-implantation is statistically correlated to properly addressing the bone deficiency for both the humeral (p = 0.005) and the ulnar (p = 0.039) components.
Comparison of Shoulder Range of Motion, Strength, and Playing Time in Uninjured High School Baseball Pitchers Who Reside in Warm- and Cold-Weather Climates
Kaplan, Kevin, ElAttrache, Neal S., Jobe, Frank W., Morrey, B.F. , Kaufman, Kenton R. , Hurd, Wendy J., Kaufman, Kenton R

The American Journal of Sports Medicine | November 4, 2010 | Volume: 39 | Issue: 2 | Pages: 320-328

10.1177/0363546510382230 Get It

Background: There is an assumption that baseball athletes who reside in warm-weather climates experience larger magnitude adaptations in throwing shoulder motion and strength compared with their peers who reside in cold-weather climates. Hypotheses: (1) The warm-weather climate (WWC) group would exhibit more pronounced shoulder motion and strength adaptations than the cold-weather climate (CWC) group, and (2) the WWC group would participate in pitching activities for a greater proportion of the year than the CWC group, with the time spent pitching predicting throwing shoulder motion and strength in both groups. Study Design: Cross-sectional study; Level of evidence, 3. Methods: One hundred uninjured high school pitchers (50 each WWC, CWC) were recruited. Rotational shoulder motion and isometric strength were measured and participants reported the number of months per year they pitched. To identify differences between groups, t tests were performed; linear regression was used to determine the influence of pitching volume on shoulder motion and strength. Results: The WWC group pitched more months per year than athletes from the CWC group, with the number of months spent pitching negatively related to internal rotation motion and external rotation strength. The WWC group exhibited greater shoulder range of motion in all planes compared with the CWC group, as well as significantly lower external rotation strength and external/internal rotation strength ratios. There was no difference in internal rotation strength between groups, nor a difference in the magnitude of side-to-side differences for strength or motion measures. Conclusion: Athletes who reside in cold- and warm-weather climates exhibit differences in throwing shoulder motion and strength, related in part to the number of months spent participating in pitching activities. The amount of time spent participating in pitching activities and the magnitude of range of motion and strength adaptations in athletes who reside in warm-weather climates may make these athletes more susceptible to throwing-related injuries.
Revision interposition arthroplasty of the elbow
Larson, A. Noelle , Adams, Robert , Morrey, B.F. , Larson, A Noelle

The Journal of Bone and Joint Surgery. British volume | August 26, 2010 | Volume: 92-B | Issue: 9 | Pages: 1273-1277

10.1302/0301-620x.92b9.24039 Get It

Between 1996 and 2008, nine patients with severe post-traumatic arthritis underwent revision of a failed interposition arthroplasty of the elbow with a further interposition procedure using an allograft of tendo Achillis at a mean of 5.6 years (0.7 to 13.1) after the initial procedure. There were eight men and one woman with a mean age of 47 years (36 to 56). The mean follow-up was 4.7 years (2 to 8). The mean Mayo Elbow Performance score improved from 49 (15 to 65) pre-operatively to 73 (55 to 95) (p = 0.04). The mean Disability of the Arm, Shoulder and Hand score was 26 (7 to 42). One patient was unavailable for clinical follow-up and one underwent total elbow replacement three months post-operatively. Of the remaining patients, one had an excellent, two had good, three fair and one a poor result. Subjectively, five of the nine patients were satisfied. Four continued manual labour. Revision interposition arthroplasty is an option for young, active patients with severe post-traumatic arthritis who require both mobility and durability of the elbow.
Failure of metal radial head replacement
Riet, R. P. van, Sanchez-Sotelo, Joachin, Morrey, B.F. , Riet, R. P. van, Sanchez-Sotelo, J.

The Journal of Bone and Joint Surgery. British volume | April 30, 2010 | Volume: 92-B | Issue: 5 | Pages: 661-667

10.1302/0301-620x.92b5.23067 Get It

There is little information available at present regarding the mechanisms of failure of modern metallic radial head implants. Between 1998 and 2008, 44 consecutive patients (47 elbows) underwent removal of a failed metallic radial head replacement. In 13 patients (13 elbows) the initial operation had been undertaken within one week of a fracture of the radial head, at one to six weeks in seven patients (seven elbows) and more than six weeks (mean of 2.5 years (2 to 65 months)) in 22 patients (25 elbows). In the remaining two elbows the replacement was inserted for non-traumatic reasons. The most common indication for further surgery was painful loosening (31 elbows). Revision was undertaken for stiffness in 18 elbows, instability in nine, and deep infection in two. There were signs of over-lengthening of the radius in 11 elbows. Degenerative changes were found in all but one. Only three loose implants had been fixed with cement. Instability was not identified in any of the bipolar implants.
Electrogoniometer for the Measurement of Human Elbow Joint Rotation
Chao, Edmund Y.S., An, Kai‐Nan , Askew, Linda J., Morrey, B.F.

Journal of Biomechanical Engineering | June 15, 2009 | Volume: 102 | Issue: 4 | Pages: 301-310

10.1115/1.3138227 Get It

Since the electrogoniometric method has been justified for the measurement of lower extremity joint motion, a similar device is developed for the measurement of elbow joint and forearm rotations. In this design, the axis of forearm rotation coincides with the anatomical axis which eliminates the cross talk existing in the regular triaxial goniometer. Although the axis of abduction-adduction is still offset from the elbow joint, special linkage arrangement was used to obtain equivalent motion. Experimental method was used to validate the accuracy of the device and model simulation was performed to emphasize the importance of accurate placement of the instrument on test subjects. Application of the present apparatus to normal subjects was studied to illustrate the range of elbow motion required in performing normal activities of daily living. This device is currently used in the functional evaluation of patients with elbow and forearm problems.
Management and outcome of 103 acute fractures of the coronoid process of the ulna
Morrey, B.F. , Steinmann, Scott P. , Adams, Julie , Adams, Julie E. , Hoskin, Tanya L. , Adams, Julie E

The Journal of Bone and Joint Surgery. British volume | April 30, 2009 | Volume: 91-B | Issue: 5 | Pages: 632-635

10.1302/0301-620x.91b5.21755 Get It

A series of 103 acute fractures of the coronoid process of the ulna in 101 patients was reviewed to determine their frequency. The Regan-Morrey classification, treatment, associated injuries, course and outcomes were evaluated. Of the 103 fractures, 34 were type IA, 17 type IB, ten type IIA, 19 type IIB, ten type IIIA and 13 type IIIB. A total of 44 type-I fractures (86%) were treated conservatively, while 22 type-II (76%) and all type-III fractures were managed by operation. At follow-up at a mean of 3.4 years (1 to 8.9) the range of movement differed significantly between the types of fracture (p = 0.002). Patients with associated injuries had a lower Mayo elbow performance score (p = 0.03), less extension (p = 0.03), more pain (p = 0.007) and less pronosupination (p = 0.004), than those without associated injuries. The presence of a fracture of the radial head had the greatest effect on outcome. An improvement in outcome relative to that of a previous series was noted, perhaps because of more aggressive management and early mobilisation. While not providing complete information about the true details of a fracture and its nature, the Regan-Morrey classification is useful as a broad index of severity and prognosis.
Neurolysis of the ulnar nerve for neuropathy following total elbow replacement
Rispoli, Damian M., Morrey, B.F. , Athwal, George S.

The Journal of Bone and Joint Surgery. British volume | September 30, 2008 | Volume: 90-B | Issue: 10 | Pages: 1348-1351

10.1302/0301-620x.90b10.21133 Get It

Ulnar neuropathy presents as a complication in 5% to 10% of total elbow replacements, but subsequent ulnar neurolysis is rarely performed. Little information is available on the surgical management of persistent ulnar neuropathy after elbow replacement. We describe our experience with the surgical management of this problem. Of 1607 total elbow replacements performed at our institution between January 1969 and December 2004, eight patients (0.5%) had a further operation for persistent or progressive ulnar neuropathy. At a mean follow-up of 9.2 years (3.1 to 21.7) six were clinically improved and satisfied with their outcome, although, only four had complete recovery. When transposition was performed on a previously untransposed nerve the rate of recovery was 75%, but this was reduced to 25% if the nerve had been transposed at the time of the replacement.