Back to Authors

Sanchez-Sotelo, Joachin

Mayo Clinic

Mayo Clinic

Citations 2

324. Implant Sonication Improves Microbiologic Diagnosis of Elbow Prosthetic Joint Infection
Greenwood‐Quaintance, Kerryl E. , Esper, Ronda , Sanchez-Sotelo, Joachin, Flurin, Laure , Sánchez‐Sotelo, Joaquín , Patel, Robin

Open Forum Infectious Diseases | January 2, 2021 | Volume: 7 | Issue: Supplement_1 | Pages: S234-S234

10.1093/ofid/ofaa439.520 Get It

Abstract Background With a reported incidence of up to 12%, periprosthetic joint infection (PJI) is a frequent complication of total elbow arthroplasty (TEA). Its microbiologic diagnosis is usually based on periprosthetic tissue culture (hereafter referred to as tissue culture), despite the poor sensitivity of this technique. Although implant sonication cultures have been shown to be superior to tissue cultures for hip and knee PJI diagnosis, only a single small study (including fewer than 10 infected implants) has assessed sonication of elbow arthroplasties. Methods We retrospectively analysed 116 sonicate fluid cultures from patients who underwent revision of a TEA at our Institution between 2007 and 2019, comparing results to tissue cultures. Nine elbows who had fewer than 2 tissue samples obtained during surgery were excluded. Using the IDSA guidelines to define PJI, there were 46 infected cases and 61 aseptic failures. We reviewed clinical characteristics and calculated the sensitivity and specificity of periprosthetic tissue culture compared to culture of samples obtained by implant sonication. In addition, we compared the sensitivity of tissue culture to the combination of tissue and sonicate fluid culture. Results A total of 107 elbows were included. Median ages in the aseptic failure and PJI groups were 60 and 67 years, respectively. Gender distribution was similar for both groups (PJI group 62% females; aseptic group 65% females). The most common pathogens were coagulase negative Staphylococcus species (66%), followed by Staphylococcus aureus (18%). The sensitivity of tissue culture was 63% and the sensitivity of sonicate fluid culture was 76% (p=0.14). The specificity of tissue culture was 86% and the specificity of sonicate fluid culture was 100%. Sensitivity of sonicate fluid culture in combination with tissue culture was 91% (p=0.045). Table. Comparison of tests for microbiologic diagnosis of PJI Conclusion The combination of sonicate fluid culture and tissue culture had a greater sensitivity than tissue culture alone for microbiologic diagnosis of elbow TEA infection. Disclosures Joachin Sanchez-Sotelo, M.D, PhD, Elsevier (Other Financial or Material Support, Publishing Royalties)Exactech (Consultant)Oxford Univerity Press (Other Financial or Material Support, Publishing Royalties)Stryker (Grant/Research Support)Wright (Consultant) Robin Patel, MD, Accelerate Diagnostics (Grant/Research Support)CD Diagnostics (Grant/Research Support)Contrafect (Grant/Research Support)Curetis (Consultant)GenMark Diagnostics (Consultant)Heraeus Medical (Consultant)Hutchison Biofilm Medical Solutions (Grant/Research Support)Merck (Grant/Research Support)Next Gen Diagnostics (Consultant)PathoQuest (Consultant)Qvella (Consultant)Samsung (Other Financial or Material Support, Dr. Patel has a patent on Bordetella pertussis/parapertussis PCR issued, a patent on a device/method for sonication with royalties paid by Samsung to Mayo Clinic, and a patent on an anti-biofilm substance issued.)Selux Dx (Consultant)Shionogi (Grant/Research Support)Specific Technologies (Consultant)
Failure of metal radial head replacement
Riet, R. P. van, Sanchez-Sotelo, Joachin, Morrey, B.F. , Riet, R. P. van, Sanchez-Sotelo, J.

The Journal of Bone and Joint Surgery. British volume | April 30, 2010 | Volume: 92-B | Issue: 5 | Pages: 661-667

10.1302/0301-620x.92b5.23067 Get It

There is little information available at present regarding the mechanisms of failure of modern metallic radial head implants. Between 1998 and 2008, 44 consecutive patients (47 elbows) underwent removal of a failed metallic radial head replacement. In 13 patients (13 elbows) the initial operation had been undertaken within one week of a fracture of the radial head, at one to six weeks in seven patients (seven elbows) and more than six weeks (mean of 2.5 years (2 to 65 months)) in 22 patients (25 elbows). In the remaining two elbows the replacement was inserted for non-traumatic reasons. The most common indication for further surgery was painful loosening (31 elbows). Revision was undertaken for stiffness in 18 elbows, instability in nine, and deep infection in two. There were signs of over-lengthening of the radius in 11 elbows. Degenerative changes were found in all but one. Only three loose implants had been fixed with cement. Instability was not identified in any of the bipolar implants.