Clinical acceptance testing and scanner comparison of ultrasound shear wave elastography
Long, Zaiyang , Tradup, Donald J., Stekel, Scott F. , Chen, Shigao , Glazebrook, Katrina N. , Hangiandreou, Nicholas J., Song, Pengfei

Journal of Applied Clinical Medical Physics | March 15, 2018 | Volume: 19 | Issue: 3 | Pages: 336-342

10.1002/acm2.12310 Get It

AbstractBecause of the rapidly growing use of ultrasound shear wave elastography (SWE) in clinical practices, there is a significant need for development of clinical physics performance assessment methods for this technology. This study aims to report two clinical medical physicists’ tasks: (a) acceptance testing (AT) of SWE function on ten commercial ultrasound systems for clinical liver application and (b) comparison of SWE measurements of targets across vendors for clinical musculoskeletal application. For AT, ten GE LOGIQ E9 XDclear 2.0 scanners with ten C1‐6‐D and ten 9L‐D transducers were studied using two commercial homogenous phantoms. Five measurements were acquired at two depths for each scanner/transducer pair by two operators. Additional tests were performed to access effects of different coupling media, phantom locations and operators. System deviations were less than 5% of group mean or three times standard deviation; therefore, all systems passed AT. A test protocol was provided based on results that no statistically significant difference was observed between using ultrasound gel and salt water for coupling, among different phantom locations, and that interoperator and intraoperator coefficient of variation was less than 3%. For SWE target measurements, two systems were compared — a Supersonic Aixplorer scanner with a SL10‐2 and a SL15‐4 transducer, and an abovementioned GE scanner with 9L‐D transducer. Two stepped cylinders with diameters of 4.05–10.40 mm were measured both longitudinally and transaxially. Target shear wave speed quantification was performed using an in‐house MATLAB program. Using the target shear wave speed deduced from phantom specs as a reference, SL15‐4 performed the best at the measured depth. However, it was challenging to reliably measure a 4.05 mm target for either system. The reported test methods and results could provide important information when dealing with SWE‐related tasks in the clinical environment.
Shear elasticity and shear viscosity imaging in viscoelastic phantoms
Yang, Yiqun , McGough, Robert J., Song, Pengfei , Chen, Shigao , Urban, Matthew W.

The Journal of the Acoustical Society of America | June 10, 2017 | Volume: 141 | Issue: 5_Supplement | Pages: 3720-3721

10.1121/1.4988148 Get It

Shear wave elasticity imaging determines the mechanical parameters of soft tissue by analyzing measured shear waves induced by an acoustic radiation force. Currently, the widely used time-of-flight method calculates the correlation between shear waveforms at adjacent lateral observation points to estimate the shear elasticity value. Although this method provides accurate estimates of the shear elasticity in purely elastic media, our experience suggests that this approach overestimates the shear elasticity values in viscoelastic media because the effects of diffraction, attenuation, and dispersion are not taken into account. To address this problem, we have developed an approach that directly accounts for all of these effects when estimating the shear elasticity. This new approach simulates shear waveforms using a Green’s function-based approach with a Voigt model, while the shear elasticity and viscosity values are estimated using an optimization-based approach by comparing measured shear waveforms with simulated shear waveforms in the time-domain. This operation is then performed on a point-by-point basis to generate images. The results indicate that there is good agreement between the simulated and measured shear velocity waveforms, and that this approach yields improved images of the shear elasticity and shear viscosity. [Work supported, in part, by NIH Grant R01DK092255.]
Shear wave phase velocity dispersion estimation in viscoelastic materials using the Multiple Signal Classification method
Qiang, Bo, Amador, Carolina , Urban, Matthew W. , Kijanka, Piotr , Song, Pengfei , Chen, Shigao

The Journal of the Acoustical Society of America | June 10, 2017 | Volume: 141 | Issue: 5_Supplement | Pages: 3720-3720

10.1121/1.4988145 Get It

Shear wave elastography (SWE) is clinically used for the measurement of soft tissue mechanical properties. Most SWE methods assume that the tissue is elastic, but soft tissues are inherently viscoelastic. The viscoelasticity can be characterized by examining phase velocity dispersion. Methods to extract the phase velocities from the spatiotemporal data, v(x,t), involve using a two-dimensional Fourier transform. The Fourier representation, V(k,f), is searched for peaks that correspond to the phase velocities. We present a method that uses the Multiple Signal Classification (MUSIC) method to provide robust estimation of the phase velocity dispersion curves. We compared results from the MUSIC method with the current approach of searching for peaks in the V(k,f) representation. We tested this method on digital phantom data created using finite element models (FEMs) in viscoelastic media excited by a simulated acoustic radiation force push from a curved linear array. We evaluated the algorithm with different levels of added noise. Additionally, we tested the methods on data acquired in viscoelastic phantoms with a Verasonics system. The MUSIC algorithm provided dispersion estimation with lower errors than the conventional peak search strategy. This method can be used for evaluation of wave velocity dispersion in viscoelastic tissues and guided wave propagation. [This work was supported in part by grant R01DK092255.]
Quantifying passive muscle stiffness in children with and without cerebral palsy using ultrasound shear wave elastography
Brandenburg, Joline E. , Eby, Sarah F. , Song, Pengfei , Kingsley‐Berg, Shirley, Bamlet, William R. , Sieck, Gary C. , An, Kai‐Nan, Bamlet, William, An, Kai‐Nan , Sieck, Gary , Bamlet, William R , Song, Pengfei

Developmental Medicine & Child Neurology | July 4, 2016 | Volume: 58 | Issue: 12 | Pages: 1288-1294

10.1111/dmcn.13179 Get It

AimThe aim of this study was to compare passive muscle stiffness in children with cerebral palsy (CP) and children with typical development using a novel ultrasound technique: ultrasound shear wave elastography (SWE).MethodWe conducted a prospective study of 13 children with CP (six females and seven males, median age 5y 1mo [interquartile range 4y 4mo–7y 8mo]) and 13 children with typical development (six females and seven males, median age 5y 3mo [interquartile range 4y 4mo–9y 4mo]). Demographic information and physical exam measurements were obtained in addition to shear modulus measurements (passive muscle stiffness) of the lateral gastrocnemius muscle at 20° plantar flexion, 10° plantar flexion, and 0° plantar flexion using SWE.ResultsChildren with CP had significantly greater shear modulus measurements at all three foot positions (p<0.050). When the shear modulus values were normalized to the baseline value for each child, there was no significant difference between the two groups.InterpretationPassive muscle stiffness, measured without the influence of spasticity, is greater in children with CP than in children with typical development when a muscle is at slack and at stretch. When shear modulus was normalized, the results indicate that muscle in children in both groups responds similarly to passive stretch. Further work includes evaluating effect of botulinum toxin on passive muscle properties.
Investigation of the effects of myocardial anisotropy for shear wave elastography using impulsive force and harmonic vibration
Qiang, Bo, Song, Pengfei , Nenadic, Ivan , Chen, Shigao , Greenleaf, James F. , Urban, Matthew W. , Nenadic, Ivan Z, Song, Pengfei

Physics in Medicine & Biology | December 16, 2015 | Volume: 61 | Issue: 1 | Pages: 365-382

10.1088/0031-9155/61/1/365 Get It

Abstract The myocardium is known to be an anisotropic medium where the muscle fiber orientation changes through the thickness of the wall. Shear wave elastography methods use propagating waves which are measured by ultrasound or magnetic resonance imaging (MRI) techniques to characterize the mechanical properties of various tissues. Ultrasound- or MR-based methods have been used and the excitation frequency ranges for these various methods cover a large range from 24–500 Hz. Some of the ultrasound-based methods have been shown to be able to estimate the fiber direction. We constructed a model with layers of elastic, transversely isotropic materials that were oriented at different angles to simulate the heart wall in systole and diastole. We investigated the effect of frequency on the wave propagation and the estimation of fiber direction and wave speeds in the different layers of the assembled models. We found that waves propagating at low frequencies such as 30 or 50 Hz showed low sensitivity to the fiber direction but also had substantial bias in estimating the wave speeds in the layers. Using waves with higher frequency content (>200 Hz) allowed for more accurate fiber direction and wave speed estimation. These results have particular relevance for MR- and ultrasound-based elastography applications in the heart.
Simulation of wave propagation in anisotropic and viscoelastic tissues
Qiang, Bo, Aristizabal, Sara , Nenadic, Ivan , McGough, Robert J., Greenleaf, James F. , Urban, Matthew W. , Song, Pengfei , Chen, Shigao

The Journal of the Acoustical Society of America | October 14, 2015 | Volume: 138 | Issue: 3_Supplement | Pages: 1906-1906

10.1121/1.4933994 Get It

Many methods for characterization of the mechanical properties of soft tissues using propagating shear waves have been developed over the past two decades. Most of these methods assume that the shear wave is traveling in an elastic, isotropic tissue. However, many soft tissues are viscoelastic and have material properties that are directionally dependent or anisotropic. We have been developing methods to measure waves propagating in soft tissues to estimate the anisotropic viscoelastic material properties. To refine our measurement methods, we have also developed techniques and models for simulating the wave propagation in these types of materials. We have developed specialized finite element and pseudo-spectral models that can simulate viscoelastic transversely isotropic materials and compared our results with measurements in ex vivo porcine muscle. Additionally, we have developed a finite element model that simulates wave propagation in the myocardium by creating a model of layered transverse isotropic media oriented at different angles. We examined the effect of frequency of the waves for estimating of the angle of propagation. We compared these simulation results with experimental results from an ex vivo porcine left ventricular wall. These simulation methods provide insight for optimizing our measurement methods for in vivo characterization of material properties.
Feasibility assessment of shear wave elastography to rotator cuff muscle
Itoigawa, Yoshiaki , Sperling, John W. , Steinmann, Scott P. , Chen, Qingshan , Song, Pengfei , Chen, Shigao , An, Kai‐Nan, Itoi, Eiji , Hatta, Taku , An, Kai‐Nan , Song, Pengfei

Clinical Anatomy | December 30, 2014 | Volume: 28 | Issue: 2 | Pages: 213-218

10.1002/ca.22498 Get It

Pre‐surgical measurement of supraspinatus muscle extensibility is important for rotator cuff repair. The purpose of the present study was to explore the potential feasibility of a shear wave ultrasound elastography (SWE)‐based method, combined with B‐mode ultrasound, to measure the in vivo stiffness of the supraspinatus muscle non‐invasively and thus obtain key information about supraspinatus muscle extensibility. Our investigation comprised two steps. First, we determined the orientation of the supraspinatus muscle fibers in cadaveric shoulders without rotator cuff tear in order to optimize the ultrasound probe positions for SWE imaging. Second, we investigated the feasibility of quantifying the stiffness of the normal supraspinatus muscle by SWE in vivo. The supraspinatus muscle was divided into four anatomical regions: anterior superficial (AS), posterior superficial (PS), anterior deep (AD), and posterior deep (PD). Each region was examined by SWE. The SWE stiffnesses of AD, AS, PD, and PS were 40.0 ± 12.4, 34.0 ± 9.9, 32.7 ± 12.7, 39.1 ± 15.7 kPa, respectively. SWE combined with B‐Mode ultrasound imaging could be a feasible method for quantifying the local stiffness of the rotator cuff muscles. Clin. Anat. 28:213–218, 2015. © 2014 Wiley Periodicals, Inc.
Poster 548 Gender and Foot Dominance Do Not Influence Passive Muscle Stiffness of the Gastrocnemius Muscle in Typically Developing Children
Brandenburg, Joline E. , Song, Pengfei , Zhao, Heng , Landry, Bradford W., An, Kai‐Nan, Eby, Sarah F. , Chen, Shigao , An, Kai‐Nan , Song, Pengfei

PM&R | September 29, 2014 | Volume: 6 | Issue: 9S | Pages: No page available

10.1016/j.pmrj.2014.08.384 Get It

Robust shear wave motion tracking using ultrasound harmonic imaging
Zhao, Heng , Manduca, Armando, Kinnick, Randall R., Greenleaf, James F. , Song, Pengfei , Urban, Matthew W. , Pislaru, Sorin V. , Chen, Shigao

The Journal of the Acoustical Society of America | November 1, 2013 | Volume: 134 | Issue: 5_Supplement | Pages: 4010-4010

10.1121/1.4830628 Get It

Robust shear-wave motion detection is essential for producing reliable shear elasticity measurements for ultrasound shear-wave elastography (SWE). However, because shear-wave motion is extracted from radiofrequency signals which can be heavily contaminated by noise, shear-wave motion detection can be very challenging, especially for in vivo applications. This study investigated the implementation of harmonic imaging (HI) to facilitate more robust shear-wave tracking based on HI’s effectiveness in suppressing imaging noise associated with ultrasound reverberation, phase aberration, and clutter noise. A HI shear-wave tracking sequence was developed combining the pulse-inversion HI method with the plane wave imaging technique to transmit phase-inverted pulses at a high frame rate of several kilohertz. The backscattered ultrasound signals from phase-inverted pulses were added to suppress the fundamental and enhance the second harmonic component, from which the shear-wave motion was extracted. A pork belly phantom experiment showed that HI could significantly improve shear-wave motion detection by producing almost three-fold less underestimation of shear-wave motion and over ten-fold more precision for shear-wave speed measurements than fundamental imaging. An in vivo transthoracic case study of a human heart showed that HI substantially improved the success rate of shear-wave motion detection and could provide consistent estimates of the left ventricle myocardium stiffness.
Application of shear wave imaging and shear wave dispersion ultrasound vibrometry in assessing viscoelastic properties of human thyroid: In vivo pilot study
Amador, Carolina , Urban, Matthew W. , Callstrom, Matthew R. , Greenleaf, James F. , Mehrmohammadi, Mohammad , Song, Pengfei , Morris, John C. , Chen, Shigao , Fatemi, Mostafa , Alizad, Azra , Urban, Matthew W

The Journal of the Acoustical Society of America | November 1, 2013 | Volume: 134 | Issue: 5_Supplement | Pages: 4009-4009

10.1121/1.4830625 Get It

Thyroid cancer is the fastest growing age and gender adjusted cancer in 2011 according the American Cancer Society. The majority of the clinically diagnosed thyroid nodules are benign while less than 5% represent intrathyroidal cancers. Currently, the clinical gold-standard procedure for assessing the thyroid nodules is needle biopsy, a procedure that is associated with significant financial burden as well as pain and risk for patients. Therefore, a noninvasive, affordable, and potentially widely available method to differentiate between benign and malignant thyroid nodules can play an important role in reducing the number of unnecessary biopsies. In this study, we investigate the feasibility of two acoustic radiation force elastography techniques, shear wave dispersion ultrasound vibrometry (SDUV) and comb-push ultrasound shear wave elastography (CUSE imaging), in identifying thyroid nodules (imaging) and differentiating between benign and malignant pathologies based on their elasticity and viscosity (SDUV measurements). Our preliminary results show that the measured shear elasticity and shear viscosity parameters depend on tissue type; hence, these measurements may be utilized to differentiate between healthy normal thyroid tissue, benign nodules, and malignant nodules. Further studies on a large population of patients is required to better evaluate the role of the combination of elasticity and viscosity properties of tissue in differentiating various thyroid nodules.