Back to Authors

Bunch, T. Jared

https://orcid.org/0000-0001-5349-0136

Mayo Clinic

University of Utah

Citations 23

Abstract 12970: High Power Short Duration and Low Power Long Duration in Atrial Fibrillation Ablation: A Systematic Review and Meta-analysis
Techorueangwiwat, Chol, Leesutipornchai, Thiratest , Vutthikraivit, Wasawat , Bunch, T. Jared , Kewcharoen, Jakrin , Kanitsoraphan, Chanavuth , Rattanawong, Pattara , Navaravong, Leenhapong

Circulation | May 10, 2021 | Volume: 142 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.142.suppl_3.12970 Get It

Background: Although high power, shorter duration (HPSD) ablation and low power, longer duration (LPLD) ablation strategies for atrial fibrillation (AF) are frequently advocated to enhance safety and efficacy, there exists a need for comparative data from large populations. We performed a meta-analysis to compare arrhythmia-free survival, procedure time and complications rates between the two strategies. Methods: We searched the databases of MEDLINE and EMBASE from inception to April 2020. Included studies were case-control studies, cohort studies, or randomized controlled trials that compared patients undergoing HPSD and LPLD strategies for AF ablation and reported either of the following outcomes: freedom from atrial tachyarrhythmia (AT) including AF and atrial flutter, procedure time, or periprocedural complications. Data from each study were combined using the random-effects model to calculate odds ratio (OR) and weighted mean difference (WMD) with 95% confidence interval (CI). Results: Ten studies from 2006 to 2020 involving 2,189 patients were included (1,350 patients underwent HPSD strategy and 839 patients underwent LPLD strategy). Both HPSD and LPLD strategies resulted in a similar freedom from AT at 12-month follow-up (OR=1.36, 95% CI:0.91-2.04, p=0.13, Figure 1A). HPSD strategy did result in a significant reduction in total procedure time (WMD=47.34, 95% CI:29.47-65.21, p<0.001, Figure 1B) compared to LPSD. HPSD wasn’t associated with reduction in esophageal ulcer/arterioesophageal fistula (OR=0.35, 95%CI=0.12-1.06, p=0.06) or pericardial effusion/cardiac tamponade (OR=0.96, 95%CI: 0.24-3.79, p=0.95) Conclusions: In this large meta-analysis both LPLD and HPSD are equally effective and safe. Although HPSD is often advocated to reduce esophageal injury, risk was similar between approaches. However, HPSD strategy significantly lowers procedure times.
Smart Wearables for Cardiac Monitoring—Real-World Use beyond Atrial Fibrillation
Duncker, David , Ding, Wern Yew , Etheridge, Susan P. , Veltmann, Christian , Bunch, T. Jared , Gupta, Dhiraj , Veltmann, Christian , Yao, Xiaoxi , Gupta, Dhiraj , Duncker, David , Noseworthy, Peter A.

Sensors | April 5, 2021 | Volume: 21 | Issue: 7 | Pages: 2539

10.3390/s21072539 Get It

The possibilities and implementation of wearable cardiac monitoring beyond atrial fibrillation are increasing continuously. This review focuses on the real-world use and evolution of these devices for other arrhythmias, cardiovascular diseases and some of their risk factors beyond atrial fibrillation. The management of nonatrial fibrillation arrhythmias represents a broad field of wearable technologies in cardiology using Holter, event recorder, electrocardiogram (ECG) patches, wristbands and textiles. Implementation in other patient cohorts, such as ST-elevation myocardial infarction (STEMI), heart failure or sleep apnea, is feasible and expanding. In addition to appropriate accuracy, clinical studies must address the validation of clinical pathways including the appropriate device and clinical decisions resulting from the surrogate assessed.
484Impact of AF type on the outcome of atrial fibrillation ablation: insights from the CABANA trial
Monahan, Kristi H. , Bunch, T. Jared , Poole, Jeanne E. , Bahnson, Tristram D. , Al‐Khalidi, Hussein R. , Lee, K L, Packer, Douglas L. , Silverstein, A , Mark, Daniel B.

European Heart Journal | October 21, 2019 | Volume: 40 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehz747.0134 Get It

Abstract Background Prior studies suggest that catheter ablation (ABL) for atrial fibrillation (AF) is a treatment option for patients (pts) with paroxysmal AF (PAF). Pts with persistent (Per) or long-standing persistent (LSP) were routinely excluded from most ABL based clinical trials. The effectiveness of ABL compared to drug therapy (MED) in relation to underlying AF type has not been evaluated in a large randomized clinical trial. Objective To assess the impact of AF type on clinical outcomes of ABL vs. MED in pts with AF. Methods The CABANA trial randomized 2204 pts with AF at 126 sites worldwide to ABL vs. MED with rate or rhythm control drugs. The primary endpoint was a composite of death, disabling stroke, severe bleeding, or cardiac arrest. Key secondary endpoints included mortality and recurrence of AF. Outcomes of ABL vs. MED were compared within subgroups defined by AF type using Intention-to-Treat (ITT) analyses. Results Of the 2204 pts, 946 had PAF, 1042 had Per and 215 presented with LSP. There were baseline differences among AF types in age, gender, HTN, LVH, CHF and NYHA Class. For the primary endpoint, there were no significant differences between ABL and MED in pts with PAF (hazard ratio (HR) 0.82; 95% confidence interval (CI) 0.51, 1.31), Per (HR 0.87; 95% CI 0.59, 1.28), or LSP (HR 1.01, 95% CI 0.39, 2.61). Likewise, there were no significant treatment differences in mortality; PAF (HR 0.84; 95% CI 0.46, 1.52), Per (HR 0.90; 95% CI 0.56, 1.46) and LSP (HR 0.67, 95% CI 0.23, 1.94). Post-blanking AF (time to first recurrence) was significantly reduced by ABL compared to MED across all AF types (PAF by 51%), (Per by 47%) and (LSP by 36%). Clinical Characteristics and Outcomes Clinical Outcomes Comparing ABL vs. MED (HR and 95% CI) Interaction p-value Primary Endpoint 0.82 (0.51, 1.31) 0.87 (0.59, 1.28) 1.01 (0.39, 2.61) 0.925 Mortality 0.84 (0.46, 1.52) 0.90 (0.56, 1.46) 0.67 (0.23, 1.94) 0.881 Recurrent AF 0.49 (0.38, 0.62) 0.53 (0.43, 0.65) 0.64 (0.41, 1.01) 0.564 Conclusion Pts with LSP have a lower proportion of women, and a higher proportion with manifestations of heart failure despite lower CHA2DS2VASc scores. By ITT analysis, there is no significant effect of ABL compared to MED in the primary endpoint or mortality in any AF group. However, ABL is more effective than MED for reducing recurrences of AF regardless of AF type, but with a greater effect in PAF vs Per vs LSP. Acknowledgement/Funding NIH, St Jude Medical Foundation and Corporation, Biosense Webster Inc., Medtronic Corporation, and Boston Scientific Corporation
Mechanisms and Utility of Discrete Great Arterial Potentials in the Ablation of Outflow Tract Ventricular Arrhythmias
Bunch, T. Jared , Asirvatham, Samuel J. , Edwards, William D. , Friedman, Paul A. , Munger, Thomas M. , Hammill, Stephen C., Cha, Yong‐Mei , Brady, Peter A. , Rea, Robert F., Packer, Douglas L. , Shen, Win-Kuang, Srivathsan, Komandoor , Jahangir, Arshad , Bradley, David J. , Asirvatham, Samuel J

Circulation: Arrhythmia and Electrophysiology | June 5, 2008 | Volume: 1 | Issue: 1 | Pages: 30-38

10.1161/circep.107.750315 Get It

Background— Outflow tract ventricular tachycardia originating above the semilunar valves has been reported in a small number of studies. Discrete potentials in the great arteries (above the semilunar valves) have been rarely described in patients undergoing electrophysiology evaluation and radiofrequency ablation for ventricular arrhythmias. The mechanisms of these discrete potentials in the great arteries and the utility of such potentials in guiding radiofrequency ablation are unknown. Methods and Results— Twelve patients with outflow tract ventricular arrhythmia originating above the semilunar valves with discrete arterial potentials were studied. The clinical characteristics, properties of the arterial potentials, electrophysiological evaluation and ablation, and short- and long-term outcomes were reviewed. Of the twelve patients, 8 (67%) were women. The patients’ average age was 41�14 years. The average ejection fraction was 0.52�0.16 (range: 0.16 to 0.75). Contact mapping in the great artery demonstrated discrete near-field electrograms that were separate from far-field ventricular electrograms in all patients (8 above the pulmonary valve and in 4 the aortic valve). One or more of the following electrophysiological characteristics, supportive of an arrhythmogenic substrate, were observed in 10 of 12 patients: (1) A fixed or reproducibly variable pattern of discrete potential–ventricular arrhythmia relationship was present at baseline or during pacing; (2) the discrete potential–ventricular electrogram relationship during sinus rhythm was the reverse of that during the ventricular arrhythmia; (3) during sustained ventricular tachycardia, spontaneous variation of the ventricular (V-V) cycle length was preceded by a similar variation of arterial spike potential–spike potential cycle length; and (4) ablation guided by the discrete arterial potential successfully eliminated the clinical arrhythmia. Ablation was successful in these patients. In the remaining 2 patients, the potentials were believed to be bystanders. Over 10�4 months (range: 5 to 32 months) of follow-up, there have been no recurrences of the premature ventricular complex or ventricular arrhythmia. Conclusions— Discrete potentials are present in the great arteries of a select group of patients with outflow tract ventricular tachycardia originating above the semilunar valves. When an arrhythmogenic relationship can be demonstrated, discrete potentials are useful in guiding ablation within the great vessels, despite significant anatomic complexity.
Three-Dimensional Ultrasound for Image-Guided Mapping and Intervention
Henz, Benhur Davi , Johnson, Susan B., Bunch, T. Jared , O'BRIEN, CHRISTINE J., Hodge, David O. , Altman, Andres, Govari, Assaf , Packer, Douglas L. , Okumura, Yasuo

Circulation: Arrhythmia and Electrophysiology | April 30, 2008 | Volume: 1 | Issue: 2 | Pages: 110-119

10.1161/circep.108.769935 Get It

Background— Multiple factors create discrepancies between electroanatomic maps and merged, preacquired computed tomographic images used in guiding atrial fibrillation ablation. Therefore, a Carto-based 3D ultrasound image system (Biosense Webster Inc) was validated in an animal model and tested in 15 atrial fibrillation patients. Methods and Results— Twelve dogs underwent evaluation using a newly developed Carto-based 3D ultrasound system. After fiducial clip markers were percutaneously implanted at critical locations in each cardiac chamber, 3D ultrasound geometries, derived from a family of 2D intracardiac echocardiographic images, were constructed. Point-source error of 3D ultrasound-derived geometries, assessed by actual real-time 2D intracardiac echocardiographic clip sites, was 2.1�1.1 mm for atrial and 2.4�1.2 mm for ventricular sites. These errors were significantly less than the variance on CartoMerge computed tomographic images (atria: 3.3�1.6 mm; ventricles: 4.8�2.0 mm; P< 0.001 for both). Target ablation at each clip, guided only by 3D ultrasound-derived geometry, resulted in lesions within 1.1�1.1 mm of the actual clips. Pulmonary vein ablation guided by 3D ultrasound-derived geometry resulted in circumferential ablative lesions. Mapping in 15 patients produced modestly smaller 3D ultrasound versus electroanatomic map left atrial volumes (98�24 cm 3 versus 109�25 cm 3 , P< 0.05). Three-dimensional ultrasound-guided pulmonary vein isolation and linear ablation in these patients were successfully performed with confirmation of pulmonary vein entrance/exit block. Conclusions— These data demonstrate that 3D ultrasound images seamlessly yield anatomically accurate chamber geometries. Image volumes from the ultrasound system are more accurate than possible with CartoMerge computed tomographic imaging. This clinical study also demonstrates the initial feasibility of this guidance system for ablation in patients with atrial fibrillation.
Progression of Nonculprit Plaque Stenosis Following Successful Percutaneous Intervention
Bunch, T. Jared , Rihal, Charanjit S. , Gumina, Richard J. , Cooper, Leslie T. , Caplice, Noel M. , Rihal, Charanjit S. , Cooper, Leslie T

Angiology | April 3, 2008 | Volume: 59 | Issue: 2 | Pages: 236-239

10.1177/0003319707306446 Get It

Despite percutaneous intervention after an acute coronary syndrome, patients remain at high risk for recurrent events in the first year. Prior studies have shown that a plaque rupture can occur not only at a single culprit lesion site but also in other atherosclerotic plaques throughout the coronary vasculature in patients with stable angina, silent myocardial ischemia, and during acute coronary syndromes. A 71-year-old man who presented with exertional angina and who had a successful stent in a culprit right coronary artery is described in this article. After 4 weeks, he represented with accelerated angina. A prior lesion in the obtuse marginal artery, remote from the site of the index lesion, had progressed from a 30% to 90% stenosis. This case report demonstrates the systemic nature of acute coronary syndromes, highlights the inherent instability of coronary artery disease, and supports the notion of aggressive secondary prevention in these patients.
Mechanisms of Sudden Cardiac Death in Myocardial Infarction Survivors
Bunch, T. Jared , Hohnloser, Stefan H. , Gersh, Bernard J.

Circulation | May 7, 2007 | Volume: 115 | Issue: 18 | Pages: 2451-2457

10.1161/circulationaha.106.683235 Get It

Impact of Transforming Growth Factor-β1 on Atrioventricular Node Conduction Modification by Injected Autologous Fibroblasts in the Canine Heart
Bunch, T. Jared , Mahapatra, Srijoy, Bruce, G. Keith, Johnson, Susan B., Miller, Dylan V. , Horne, Benjamin D. , Wang, Xiao-Li, Lee, Hon-Chi, Caplice, Noel M. , Packer, Douglas L. , Wang, Shaohua , Wang, Xiao-Li

Circulation | May 23, 2006 | Volume: 113 | Issue: 21 | Pages: 2485-2494

10.1161/circulationaha.105.570796 Get It

Background— Atrioventricular (AV) nodal ablation for management of atrial fibrillation (AF) is irreversible and requires permanent pacemaker implantation. We hypothesized that as an alternative, implantation of autologous fibroblasts in the perinodal region would focally modify AV nodal conduction and that this modulation would be enhanced by pretreatment with transforming growth factor-β1 (TGF-β1), a stimulant of fibroblasts. Methods and Results— Skin biopsies were taken from 12 mongrel dogs, and derived fibroblasts were dissociated and grown in culture for 2 weeks. Multiple injections (0.25 mL) were made through an 8F NOGA catheter along the fast/slow AV nodal pathways as guided by an electroanatomic mapping system. Seven dogs received fibroblasts alone (1×10 6 cells/mL), 7 dogs received TGF-β1 (5 μg), 4 dogs received fibroblasts and TGF-β1 (1×10 6 cells/mL+5 μg), and 4 dogs received saline only. AV node function was assessed at baseline and after 4 weeks. Saline (80 mL) with assigned therapy (0.25 mL per injection) was injected into the peri-AV nodal region in each dog. At baseline, the AH interval (66±3 ms) and the average RR interval (331±17 ms) in pacing-induced AF were similar in each cohort. The increase in AH interval in normal sinus rhythm was longer after fibroblast (23±4 versus 5±5 ms; P =0.05) and fibroblast plus TGF-β1 (50±5 versus 5±5 ms; P <0.001) injections than with saline alone, with similar findings during high right atrium and distal coronary sinus pacing. The AH interval was not significantly increased after TGF-β1 injections. The AH interval was significantly longer after fibroblast plus TGF-β1 injections than with either therapy (TGF-β1 or fibroblasts) alone. The RR interval during AF was increased in dogs that received fibroblasts alone (110±36 versus −41±34 ms) and to a greater extent with the addition of TGF-β1 (294±108 versus −41±34 ms). No AV block was seen in any cohort at 4 weeks. Labeled fibroblasts that expressed vimentin were identified in all dogs that received cell injections at 4 weeks. Conclusions— AV nodal modification can be achieved with injected fibroblasts without the creation of AV block. The effect on AV node conduction is substantially enhanced by pretreatment of fibroblasts with TGF-β1. These data have therapeutic potential for the management of rapid ventricular rate during AF without pacemaker implantation.
Promoting Arrhythmia Susceptibility
Bunch, T. Jared , Ackerman, Michael

Circulation | January 23, 2006 | Volume: 113 | Issue: 3 | Pages: 330-332