Back to Authors

Basu, Rita

https://orcid.org/0000-0002-7827-9422

Mayo Clinic

University of Alabama at Birmingham

Citations 85

Continuous Glucose Monitor Interference With Commonly Prescribed Medications: A Pilot Study
Basu, Ananda , Slama, Michael , Nicholson, Wayne T. , Langman, Loralie J., Peyser, Thomas A. , Carter, Rickey E. , Basu, Rita , Slama, Michael Q, Langman, Loralie, Carter, Rickey E

Journal of Diabetes Science and Technology | March 23, 2017 | Volume: 11 | Issue: 5 | Pages: 936-941

10.1177/1932296817697329 Get It

Background: Reliability of continuous glucose monitors (CGM) is a prerequisite for therapeutic dosing of insulin without the need for confirmatory blood glucose meter measurements. Interference of CGMs with commonly prescribed substances has not been extensively evaluated. Methods: We sought to undertake a novel pilot study to determine the susceptibility of FDA-approved CGM systems (Medtronic Guardian Sof-Sensor, Dexcom G4 Platinum) to erroneous readings in the presence of common medications. CGMs were placed on the abdomen of healthy subjects 48 hours prior to study. Subjects were admitted to the Clinical Research Trials Unit (CRTU) on the evening before study and fed a standard supper. The following morning, an oral medication was administered in the fasted state and blood was sampled for 9 hours. CGM values were compared to ambient glucose (measured with YSI) to observe variations in CGM readings. Microdialysis catheters were also placed in the abdomen to sample interstitial fluid (ISF) for drug concentrations. Results: Nineteen healthy drug-naïve subjects without diabetes participated in the study. A drug/substance was tested up to a maximum of nine times on separate occasions. Comparison of CGM glucose patterns to actual plasma glucose concentrations show several drugs, including lisinopril, albuterol, and acetaminophen, appear to interfere with commonly used CGM devices. Wine also interfered with CGM readings. Conclusions: We conclude there is some evidence of CGM interference with lisinopril, albuterol, acetaminophen, atenolol, and red wine. Future studies are required to address interference with newer sensors being approved or in the process of approval.
Interstitial Fluid Glucose Is Not Just a Shifted-in-Time but a Distorted Mirror of Blood Glucose: Insight from an In Silico Study
Schiavon, Michele , Man, Chiara Dalla , Basu, Ananda , Basu, Rita , Cobelli, Claudio , Dalla Man, Chiara , Schiavon, Michele

Diabetes Technology & Therapeutics | June 2, 2016 | Volume: 18 | Issue: 8 | Pages: 505-511

10.1089/dia.2016.0112 Get It

Background: Glucose sensors measure glucose concentration in the interstitial fluid (ISF), remote from blood. ISF glucose is well known to be “delayed” with respect to blood glucose (BG). However, ISF glucose is not simply a shifted-in-time version of BG but exhibits a more complex pattern. Methods: To gain insight into this problem, one can use linear systems theory. However, this may lose a more clinical readership, thus we use simulation and two case studies to convey our thinking in an easier way. In particular, we consider BG concentration measured after meal and exercise in 12 healthy volunteers, whereas ISF glucose is simulated using a well-accepted model of blood–ISF glucose kinetics, which permits calculation of the equilibration time, a parameter characterizing the system. Two metrics are defined: blood and ISF glucose difference at each time point and time to reach the same glucose value in blood and ISF. Results: The simulation performed and the two metrics show that the relationship between blood–ISF glucose profiles is more complex than a pure shift in time and that the pattern depends on both equilibration time and BG. Conclusions: In this in silico study, we have illustrated, with simple case studies, the meaning of the of ISF glucose with respect to BG. Understanding that ISF glucose is not just a shifted-in-time version but a distorted mirror of BG is important for a correct use of continuous glucose monitoring for diabetes management.
Effect of Pramlintide on Postprandial Glucose Fluxes in Type 1 Diabetes
Hinshaw, Ling , Schiavon, Michele , Dadlani, Vikash, Mallad, Ashwini , Man, Chiara Dalla , Bharucha, Adil E. , Basu, Rita , Geske, Jennifer R. , Carter, Rickey E. , Basu, Ananda , Kudva, Yogish C. , Dalla Man, Chiara, Bharucha, Adil, Cobelli, Claudio , Dalla Man, Chiara , Carter, Rickey E , Geske, Jennifer , Schiavon, Michele

The Journal of Clinical Endocrinology & Metabolism | March 1, 2016 | Volume: 101 | Issue: 5 | Pages: 1954-1962

10.1210/jc.2015-3952 Get It

Abstract Context: Early postprandial hyperglycemia and delayed hypoglycemia remain major problems in current management of type 1 diabetes (T1D). Objective: Our objective was to investigate the effects of pramlintide, known to suppress glucagon and delay gastric emptying, on postprandial glucose fluxes in T1D. Design: This was a single-center, inpatient, randomized, crossover study. Patients: Twelve patients with T1D who completed the study were analyzed. Interventions: Subjects were studied on two occasions with or without pramlintide. Triple tracer mixed-meal method and oral minimal model were used to estimate postprandial glucose turnover and insulin sensitivity (SI). Integrated liver insulin sensitivity was calculated based on glucose turnover. Plasma glucagon and insulin were measured. Main Outcome Measure: Glucose turnover and SI were the main outcome measures. Results: With pramlintide, 2-hour postprandial glucose, insulin, glucagon, glucose turnover, and SI indices showed: plasma glucose excursions were reduced (difference in incremental area under the curve [iAUC], 444.0 mMmin, P = .0003); plasma insulin concentrations were lower (difference in iAUC, 7642.0 pMmin; P = .0099); plasma glucagon excursions were lower (difference in iAUC, 1730.6 pg/mlmin; P = .0147); meal rate of glucose appearance was lower (difference in iAUC: 1196.2 μM/kg fat free mass [FFM]; P = .0316), endogenous glucose production was not different (difference in iAUC: −105.5 μM/kg FFM; P = .5842), rate of glucose disappearance was lower (difference in iAUC: 1494.2 μM/kg FFM; P = .0083). SI and liver insulin sensitivity were not different between study visits (P > .05). Conclusions: Inhibition of glucagon and gastric emptying delaying reduced 2-hour prandial glucose excursions in T1D by delaying meal rate of glucose appearance.
Direct Evidence of Acetaminophen Interference with Subcutaneous Glucose Sensing in Humans: A Pilot Study
Basu, Ananda , Veettil, Sona, Dyer, Roy B. , Peyser, Thomas A. , Basu, Rita , Dyer, Roy

Diabetes Technology & Therapeutics | January 19, 2016 | Volume: 18 | Issue: 2_suppl | Pages: No page available

10.1089/dia.2015.0410 Get It

Background: Recent advances in accuracy and reliability of continuous glucose monitoring (CGM) devices have focused renewed interest on the use of such technology for therapeutic dosing of insulin without the need for independent confirmatory blood glucose meter measurements. An important issue that remains is the susceptibility of CGM devices to erroneous readings in the presence of common pharmacologic interferences. We report on a new method of assessing CGM sensor error to pharmacologic interferences using the example of oral administration of acetaminophen. Materials and Methods: We examined the responses of several different Food and Drug Administration–approved and commercially available CGM systems (Dexcom [San Diego, CA] Seven ® Plus™, Medtronic Diabetes [Northridge, CA] Guardian ® , and Dexcom G4 ® Platinum) to oral acetaminophen in 10 healthy volunteers without diabetes. Microdialysis catheters were placed in the abdominal subcutaneous tissue. Blood and microdialysate samples were collected periodically and analyzed for glucose and acetaminophen concentrations before and after oral ingestion of 1 g of acetaminophen. We compared the response of CGM sensors with the measured acetaminophen concentrations in the blood and interstitial fluid. Results: Although plasma glucose concentrations remained constant at approximately 90 mg/dL (approximately 5 m M ) throughout the study, CGM glucose measurements varied between approximately 85 to 400 mg/dL (from approximately 5 to 22 m M ) due to interference from the acetaminophen. The temporal profile of CGM interference followed acetaminophen concentrations measured in interstitial fluid (ISF). Conclusions: This is the first direct measurement of ISF concentrations of putative CGM interferences with simultaneous measurements of CGM performance in the presence of the interferences. The observed interference with glucose measurements in the tested CGM devices coincided temporally with appearance of acetaminophen in the ISF. The method applied here can be used to determine the susceptibility of current and future CGM systems to interference from acetaminophen or other exogenous pharmacologic agents.
Modeling Plasma-to-Interstitium Glucose Kinetics from Multitracer Plasma and Microdialysis Data
Schiavon, Michele , Man, Chiara Dalla , Dube, Simmi , Slama, Michael , Kudva, Yogish C. , Peyser, Thomas A. , Basu, Ananda , Basu, Rita , Cobelli, Claudio , Dalla Man, Chiara , Schiavon, Michele

Diabetes Technology & Therapeutics | August 27, 2015 | Volume: 17 | Issue: 11 | Pages: 825-831

10.1089/dia.2015.0119 Get It

Background: Quantitative assessment of the dynamic relationship between plasma and interstitial fluid (ISF) glucose and the estimation of the plasma-to-ISF delay are of major importance to determine the accuracy of subcutaneous glucose sensors, an essential component of open- and closed-loop therapeutic systems for type 1 diabetes mellitus (T1DM). The goal of this work is to develop a model of plasma-to-ISF glucose kinetics from multitracer plasma and interstitium data, obtained by microdialysis, in healthy and T1DM subjects, under fasting conditions. Materials and Methods: A specific experimental design, combining administration of multiple tracers with the microdialysis technique, was used to simultaneously frequently collect plasma and ISF data. Linear time-invariant compartmental modeling was used to describe glucose kinetics from the tracer data because the system is in steady state. Results: A two-compartment model was shown accurate and was identified from both plasma and ISF data. An “equilibration time” between plasma and ISF of 9.1 and 11.0 min (median) in healthy and T1DM subjects, respectively, was calculated. Conclusions: We have demonstrated that, in steady-state condition, the glucose plasma-to-ISF kinetics can be modeled with a linear two-compartment model and that the “equilibration time” between the two compartments can be estimated with precision. Future studies will assess plasma-to-interstitium glucose kinetics during glucose and insulin perturbations in both healthy and T1DM subjects.
Nocturnal Glucose Metabolism in Type 1 Diabetes: A Study Comparing Single Versus Dual Tracer Approaches
Mallad, Ashwini , Hinshaw, Ling , Man, Chiara Dalla , Basu, Rita , Lingineni, Ravi K., Carter, Rickey E. , Kudva, Yogish C. , Basu, Ananda , Lingineni, Ravi, Cobelli, Claudio , Dalla Man, Chiara , Carter, Rickey E

Diabetes Technology & Therapeutics | June 29, 2015 | Volume: 17 | Issue: 8 | Pages: 587-595

10.1089/dia.2015.0011 Get It

Background: Understanding the effect size, variability, and underlying physiology of the dawn phenomenon is important for next-generation closed-loop control algorithms for type 1 diabetes (T1D). Subjects and Methods: We used an iterative protocol design to study 16 subjects with T1D on individualized insulin pump therapy for two successive nights. Endogenous glucose production (EGP) rates at 3 a.m. and 7 a.m. were measured with [6,6- 2 H 2 ]glucose as a single tracer, infused from midnight to 7 a.m. in all subjects. To explore possibility of tracer recycling due to prolonged [6,6- 2 H 2 ]glucose infusion, which was highly probable after preplanned interim data analyses, we infused a second tracer, [6- 3 H]glucose, from 4 a.m. to 7 a.m. in the last seven subjects to measure EGP at 7 a.m. Results: Cortisol concentrations increased during both nights, but changes in glucagon and insulin concentration were inconsistent. Although the plasma glucose concentrations rose from midnight to 7 a.m. during both nights, EGP measured with [6,6- 2 H 2 ]glucose between 3 a.m. and 7 a.m. did not differ during Night 1 but fell in Night 2. However, EGP measured with [6- 3 H]glucose at 7 a.m. was higher than that measured with [6,6- 2 H 2 ]glucose during both nights, thereby suggesting tracer recycling probably underestimating EGP calculated at 7 a.m. with [6,6- 2 H 2 ]glucose. Likewise, EGP was higher at 7 a.m. with [6- 3 H]glucose than at 3 a.m. with [6,6- 2 H 2 ]glucose during both nights. Conclusions: The data demonstrate a consistent overnight rise in glucose concentrations through increased EGP, mediated likely by rising cortisol concentrations. The observations with the dual tracer approach imply significant tracer recycling leading to underestimation of EGP measured by longer-duration tracer infusion.
Hepatic insulin sensitivity in healthy and prediabetic subjects: from a dual- to a single-tracer oral minimal model
Visentin, R. , Man, Chiara Dalla , Basu, Rita , Basu, Ananda , Rizza, Robert A., Cobelli, Claudio , Dalla Man, Chiara

American Journal of Physiology-Endocrinology and Metabolism | May 19, 2015 | Volume: 309 | Issue: 2 | Pages: E161-E167

10.1152/ajpendo.00358.2014 Get It

Recently, a model was proposed to assess hepatic insulin sensitivity during a meal, i.e., the ability of insulin to suppress glucose production (EGP), SIP. The model was developed on EGP data obtained from a triple-tracer meal and the tracer-to-tracee clamp technique and validated against the euglycemic hyperinsulinemic clamp. The aim of this study was to assess whether SIP can be obtained from plasma concentrations measured after a single-tracer meal by incorporating the above EGP model into the oral glucose minimal model by describing both glucose production and disposal (OMMPD). Triple-tracer meal data of two databases (20 healthy and 60 healthy and prediabetic subjects) were used. Virtually model-independent EGP estimates were calculated. OMMPD was identified on exogenous and endogenous glucose concentrations, providing indices of SIP, disposal insulin sensitivity (SID), and EGP. The model fitted the data well, and SIP and SID were estimated with precision in both databases (SIP = 5.48 ± 0.54 10−4 dl·kg−1·min−1 per μU/ml and SID = 9.93 ± 2.18 10−4 dl·kg−1·min−1 per μU/ml in healthy; SIP = 5.41 ± 3.55 10−4 dl·kg−1·min−1 per μU/ml and SID = 5.34 ± 6.17 10−4 dl·kg−1·min−1 per μU/ml, in healthy and prediabetic subjects). Estimated SIP and that derived from the triple-tracer EGP model were very similar on average. Moreover, the time course of EGP normalized to basal EGP (EGPb), and EGP/EGPb agreed with the results obtained using the triple-tracer method. In this study, we have demonstrated that SIP, SID, and EGP/EGPb time course can be estimated reliably from a single-tracer meal protocol in both healthy and prediabetic subjects.
Effect of Bilateral Carotid Body Resection on Cardiac Baroreflex Control of Blood Pressure During Hypoglycemia
Limberg, Jacqueline K. , Taylor, Jennifer L. , Mozer, Michael T., Dube, Simmi , Basu, Ananda , Basu, Rita , Rizza, Robert A., Curry, Timothy B. , Joyner, Michael J. , Wehrwein, Erica A. , Joyner, Michael J

Hypertension | April 14, 2015 | Volume: 65 | Issue: 6 | Pages: 1365-1371

10.1161/hypertensionaha.115.05325 Get It

Hypoglycemia results in a reduction in cardiac baroreflex sensitivity and a shift in the baroreflex working range to higher heart rates. This effect is mediated, in part, by the carotid chemoreceptors. Therefore, we hypothesized hypoglycemia-mediated changes in baroreflex control of heart rate would be blunted in carotid body–resected patients when compared with healthy controls. Five patients with bilateral carotid body resection for glomus tumors and 10 healthy controls completed a 180-minute hyperinsulinemic, hypoglycemic (≈3.3 mmol/L) clamp. Changes in heart rate, blood pressure, and spontaneous cardiac baroreflex sensitivity were assessed. Baseline baroreflex sensitivity was not different between groups ( P >0.05). Hypoglycemia resulted in a reduction in baroreflex sensitivity in both the groups (main effect of time, P <0.01) and responses were lower in resected patients when compared with controls (main effect of group, P <0.05). Hypoglycemia resulted in large reductions in systolic (−17±7 mm Hg) and mean (−14±5 mm Hg) blood pressure in resected patients that were not observed in controls (interaction of group and time, P <0.05). Despite lower blood pressures, increases in heart rate with hypoglycemia were blunted in resected patients (interaction of group and time, P <0.01). Major novel findings from this study demonstrate that intact carotid chemoreceptors are essential for increasing heart rate and maintaining arterial blood pressure during hypoglycemia in humans. These data support a contribution of the carotid chemoreceptors to blood pressure control and highlight the potential widespread effects of carotid body resection in humans.
Use of a novel triple-tracer approach to assess postprandial glucose metabolism
Basu, Rita , Toffolo, Gianna , Basu, Ananda , Shah, Pankaj, Rizza, Robert A., Camillo, Barbara Di , Vella, Adrian , Cobelli, Claudio

American Journal of Physiology-Endocrinology and Metabolism | February 27, 2015 | Volume: 284 | Issue: 1 | Pages: E55-E69

10.1152/ajpendo.00190.2001 Get It

Numerous studies have used the dual-tracer method to assess postprandial glucose metabolism. The present experiments were undertaken to determine whether the marked tracer nonsteady state that occurs with the dual-tracer approach after food ingestion introduces error when it is used to simultaneously measure both meal glucose appearance (Ra meal) and endogenous glucose production (EGP). To do so, a novel triple-tracer approach was designed: 12 subjects ingested a mixed meal containing [1-13C]glucose while [6-3H]glucose and [6,6-2H2]glucose were infused intravenously in patterns that minimized the change in the plasma ratios of [6-3H]glucose to [1-13C]glucose and of [6,6-2H2]glucose to endogenous glucose, respectively. Ra meal and EGP measured with this approach were essentially model independent, since non-steady-state error was minimized by the protocol. Initial splanchnic glucose extraction (ISE) was 12.9% ± 3.4%, and suppression of EGP (EGPS) was 40.3% ± 4.1%. In contrast, when calculated with the dual-tracer one-compartment model, ISE was higher ( P < 0.05) and EGPS was lower ( P < 0.005) than observed with the triple-tracer approach. These errors could only be prevented by using time-varying volumes different for Ra meal and EGP. Analysis of the dual-tracer data with a two-compartment model reduced but did not totally avoid the problems associated with marked postprandial changes in the tracer-to-tracee ratios. We conclude that results from previous studies that have used the dual-tracer one-compartment model to measure postprandial carbohydrate metabolism need to be reevaluated and that the triple-tracer technique may provide a useful approach for doing so.
Effect of enteral vs. parenteral glucose delivery on initial splanchnic glucose uptake in nondiabetic humans
Shah, Pankaj, Basu, Rita , Basu, Ananda , Camilleri, Michael , Schwenk, W. Frederick, Rizza, Robert A., Vella, Adrian , Schwenk, W. Frederick

American Journal of Physiology-Endocrinology and Metabolism | February 27, 2015 | Volume: 283 | Issue: 2 | Pages: E259-E266

10.1152/ajpendo.00178.2001 Get It

To determine if enteral delivery of glucose influences splanchnic glucose metabolism, 10 subjects were studied when glucose was either infused into the duodenum at a rate of 22 μmol · kg −1 · min −1 and supplemental glucose given intravenously or when all glucose was infused intravenously while saline was infused intraduodenally. Hormone secretion was inhibited with somatostatin, and glucose (∼8.5 mmol/l) and insulin (∼450 pmol/l) were maintained at constant but elevated levels. Intravenously infused [6,6- 2 H 2 ]glucose was used to trace the systemic appearance of intraduodenally infused [3- 3 H]glucose, whereas UDP-glucose flux (an index of hepatic glycogen synthesis) was measured using the acetaminophen glucuronide method. Despite differences in the route of glucose delivery, glucose production (3.5 ± 1.0 vs. 3.3 ± 1.0 μmol · kg −1 · min −1 ) and glucose disappearance (78.9 ± 5.7 vs. 85.0 ± 7.2 μmol · kg −1 · min −1 ) were comparable on intraduodenal and intravenous study days. Initial splanchnic glucose extraction (17.5 ± 4.4 vs. 14.5 ± 2.9%) and hepatic UDP-glucose flux (9.0 ± 2.0 vs. 10.3 ± 1.5 μmol · kg −1 · min −1 ) also did not differ on the intraduodenal and intravenous study days. These data argue against the existence of an “enteric” factor that directly (i.e., independently of circulating hormone concentrations) enhances splanchnic glucose uptake or hepatic glycogen synthesis in nondiabetic humans.