Back to Authors

Cha, Yong-Mei

0000-0002-5897-9464

Mayo Clinic

Department of Cardiovascular Medicine (Z.Q., H.-C.L., S.K.M., A.J.D., C.V.D.S., S.J.A., S.W., C.L., S.Z., P.P.D., H.H.C., Y.-M.C.), Mayo Clinic, Rochester, MN.

Citations 31

Implantation of leadless pacemakers via inferior vena cava filters is feasible and safe: Insights from a multicenter experience
Houmsse, Mahmoud , Karki, Roshan , Gabriels, James , Reinig, Michael, Patel, Dilesh, Hussain, Sarah, Gandhi, Gaurang , Lloyd, Michael S. , Patel, Apoor , Afzal, Muhammad R. , Cha, Yong‐Mei , Cha, Yong-Mei , Makary, Mina S. , Okabe, Toshimasa , Tamirisa, Kamala P. , Joza, Jacqueline E. , Epstein, Laurence M.

Journal of Cardiovascular Electrophysiology | October 15, 2020 | Volume: 31 | Issue: 12 | Pages: 3277-3285

10.1111/jce.14776 Get It

AbstractBackgroundThe leadless Micra transcatheter‐pacing system (Micra‐TPS) is implanted via a femoral approach using a 27‐French introducer sheath. The Micra Transcutaneous Pacing Study excluded patients with inferior vena cava (IVC) filters.ObjectiveTo examine the feasibility and safety of Micra‐TPS implantation through an IVC filter.MethodsThis multicenter retrospective study included patients with an IVC filter who underwent a Micra‐TPS implantation. Data for clinical and IVC filter characteristics, preprocedure imaging, and procedural interventions were collected. The primary outcome was a successful leadless pacemaker (LP) implantation via a femoral approach in the presence of an IVC filter. Periprocedural and delayed clinical complications were also evaluated.ResultsOf the 1528 Micra‐TPS implants attempted, 23 patients (1.5%) had IVC filters. The majority (69.6%) of IVC filters were permanent. Six (26.1%) patients underwent preprocedural imaging to assess for filter patency. One patient's filter was retrieved before LP implantation. The primary outcome was achieved in 21 of 22 patients (95.5%) with an existing IVC filter. An occluded IVC precluded LP implantation in one patient. Difficulty advancing the stiff guidewire or the 27‐Fr sheath was encountered in five patients. These cases required repositioning of the wire (n = 2), gradual sheath upsizing (n = 2), or balloon dilation of the filter (n = 1). Postprocedure fluoroscopy revealed intact filters in all cases. During a median 6‐month follow‐up, there were no clinical complications related to the filter or the Micra‐TPS.ConclusionThis multicenter experience demonstrates the feasibility and safety of Micra‐TPS implantation via an IVC filter without acute procedural or delayed clinical complications.
Prospective evaluation of the utility of magnetic resonance imaging in patients with non‐MRI‐conditional pacemakers and defibrillators
Padmanabhan, Deepak , Kella, Danesh , Isath, Ameesh , Tandon, Nidhi , Mulpuru, Siva K. , Deshmukh, Abhishek , Mehta, Ramila A. , Dalzell, Connie, Olson, Nora E., Felmlee, Joel P. , Jondal, Mary Lou, Asirvatham, Samuel J. , Watson, Robert E. , Cha, Yong‐Mei , Friedman, Paul A. , Mulpuru, Siva K , Kapa, Suraj , Mehta, Ramila, Olson, Nora, Felmlee, Joel, Jondal, Mary L, Asirvatham, Samuel J , Cha, Yong-Mei , Friedman, Paul A , Kella, Danesh K , Kapa, Suraj

Journal of Cardiovascular Electrophysiology | August 5, 2020 | Volume: 31 | Issue: 11 | Pages: 2931-2939

10.1111/jce.14705 Get It

AbstractBackgroundMagnetic resonance imaging (MRI) in patients with legacy cardiovascular implantable electronic devices (CIEDs) in situ is likely underutilized. We hypothesized the clinical benefit of MRI would outweigh the risks in legacy CIED patients.MethodsThis is a single‐center retrospective study that evaluated and classified the utility of MRI using a prospectively maintained database. The outcomes were classified as aiding in diagnosis, treatment, or both for the patients attributable to the MRI. We then assessed the incidence of adverse effects (AE) when the MRI was performed.ResultsIn 668, MRIs performed on 479 patients, only 13 (1.9%) MRIs did not aid in the diagnosis or treatment of the patient. Power‐on reset events without clinical sequelae in three scans (0.45%) were the only AE. The probability of an adverse event happening without any benefit from the MRI scan was 1.1 × 10−4. A maximum benefit in diagnosis using MRI was obtained in ruling out space‐occupying lesions (121/185 scans, 65.4%). Scans performed in patients for elucidating answers to queries in treatment were most frequently done for disease staging at long term follow‐up (167/470 scans, 35.5%). Conservative treatment (184/470 scans, 39%) followed by medication changes (153/470 scans, 28.7%) were the most common treatment decisions made.ConclusionsThe utility of MRI in patients with non‐MRI‐conditional CIEDs far outweighs the risk of adverse events when imaging is done in the context of a multidisciplinary program that oversees patient safety.
Clinical implications of elective replacement indicator setting changes in patients with dual‐chamber pacemaker devices
Phillips, Kari A. , Ponamgi, Shiva , Mundell, Benjamin F. , Krushelnytskyy, Mykhaylo , Li, Zhuo , Rea, Robert F., Deshmukh, Abhishek , Espinosa, Raúl E. , Osborn, Michael J., Friedman, Paul A. , Mulpuru, Siva K. , Cha, Yong‐Mei , Neutzling, Lori B., Munger, Thomas M. , Kancharla, Krishna , Asirvatham, Samuel J. , Mundell, Benjamin, Rea, Robert, Osborn, Michael , Friedman, Paul A , Mulpuru, Siva K , Cha, Yong-Mei , Munger, Thomas, Asirvatham, Samuel J , McLeod, Christopher J.

Journal of Cardiovascular Electrophysiology | July 16, 2020 | Volume: 31 | Issue: 10 | Pages: 2704-2710

10.1111/jce.14677 Get It

AbstractObjectiveThis study sought to determine if single‐chamber operation and/or loss of rate response (RR) during elective replacement indicator (ERI) in patients with dual‐chamber pacemakers lead to increased symptom burden, healthcare utilization, and atrial fibrillation (AF).BackgroundDual‐chamber pacemakers often change from dual‐ to single‐chamber pacing mode and/or lose RR functionality at ERI to preserve battery. Single‐chamber pacing increases the incidence of heart failure, AF, and pacemaker syndrome suggesting these changes may be deleterious.MethodsA retrospective analysis of 700 patients was completed. Three comparisons were analyzed: Comparison 1: mode change and RR loss versus no change; Comparison 2: RR loss only versus no change; Comparison 3: mode change only versus no change (in patients with no RR programmed at baseline).ResultsIn Comparison 1, 121 (46%) patients with setting changes experienced symptoms (most often dyspnea and fatigue/exercise intolerance) versus 3 (4%) without setting changes (p < .0001). Similar results were noted in Comparisons 2 and 3 (p = .0016 and p = .0001, respectively). In Comparison 1, patients with setting change sought provider contact more than patients without setting changes (p = .0001). A significant difference was not noted in Comparison 2 or 3. Overall 14 (2%) patients were hospitalized, all of whom had setting changes.ConclusionsSetting changes at ERI including a change from dual‐ to single‐chamber pacing and/or loss of RR results in a significantly increased symptom burden and increased healthcare utilization.
Electrophysiologic effects and outcomes of sympatholysis in patients with recurrent ventricular arrhythmia and structural heart disease
Cai, Cheng , Dai, Mingyan , Tian, Ying , Zhang, Pei , Wittwer, Erica D. , Rho, Richard H., Mulpuru, Siva K. , Lee, Hon‐Chi, Ackerman, Michael J. , Asirvatham, Samuel J. , Munger, Thomas M. , Friedman, Paul A. , Cha, Yong‐Mei , Dai, Ming-Yan, Kapa, Suraj , Mulpuru, Siva K , Asirvatham, Samuel J , Chen, Ming-Long , Friedman, Paul A , Cha, Yong-Mei , Kapa, Suraj , McLeod, Christopher J.

Journal of Cardiovascular Electrophysiology | June 14, 2019 | Volume: 30 | Issue: 9 | Pages: 1499-1507

10.1111/jce.14030 Get It

AbstractIntroductionAutonomic modulation has been used as a therapy to control recurrent ventricular arrhythmia (VA). This study was to explore stellate ganglion block (SGB) effect on cardiac electrophysiologic properties and evaluate the long‐term outcome of cardiac sympathetic denervation (CSD) for patients with recurrent VA and structural heart disease (SHD).Materials and MethodsPatients who had recurrent VA due to SHD were enrolled prospectively. Electrophysiologic study and ventricular tachycardia (VT) induction were performed before and after left and right SGB. VA burden and long‐term outcomes were assessed for a separate patient group who underwent left or bilateral CSD for drug‐refractory VA due to SHD.ResultsElectrophysiologic study of nine patients showed that baseline mean (SD) corrected sinus node recovery time (cSNRT) increased from 320.4 (73.3) ms to 402.9 (114.2) ms after left and 482.4 (95.7) ms after bilateral SGB (P = .03). SGB did not significantly change P‐R, QRS, and Q‐T intervals and ventricular effective refractory period, nor did the inducibility of VA. Nineteen patients underwent left (n = 14) or bilateral (n = 5) CSD. CSD reduced VA burden and appropriate ICD therapies from a median (interquartile range) of 2.5 (0.4‐11.6) episodes weekly to 0.1 (0.0‐2.4) episodes weekly at 6‐month follow‐up (P = .002). Three‐year freedom from orthotopic heart transplant (OHT) and death was 52.6%. New York Heart Association functional class III/IV and VT rate less than 160 beats per minute were predictors of recurrent VA, OHT, and death.ConclusionSGB increased cSNRT without changing heart rate. CSD was more beneficial for patients with mild‐to‐moderate heart failure and faster VA.
Real‐world experience with leadless cardiac pacing
Vaidya, Vaibhav R. , Dai, Mingyan , Asirvatham, Samuel J. , Rea, Robert F., Thome, Trena, Mulpuru, Siva K. , Venkatachalam, Kalpathi L., Ryan, J. , Friedman, Paul A. , Cha, Yong‐Mei , Thome, Trena M, Ryan, James D , Friedman, Paul A , Cha, Yong-Mei , Asirvatham, Samuel J , Srivathsan, Komandoor , Kusumoto, Fred

Pacing and Clinical Electrophysiology | January 11, 2019 | Volume: 42 | Issue: 3 | Pages: 366-373

10.1111/pace.13601 Get It

AbstractBackgroundLeadless cardiac pacing (LCP) has emerged as a new modality for permanent pacing. We sought to describe comparative outcomes between LCP and transvenous pacemakers.MethodsPatients receiving LCP (Micra [Medtronic, Minneapolis, MN, USA] and Nanostim [St. Jude Medical/Abbott Laboratories, Chicago, IL, USA]) between 2014 and 2017 at the Mayo Clinic Heart Rhythm Enterprise practice (Rochester, MN, USA; Jacksonville, FL, USA; and Scottsdale, AZ, USA) were identified. We identified 1:1 age‐ and sex‐matched controls receiving single‐chamber transvenous ventricular pacemakers (TVP). Statistical analyses were performed with JMP 13.0.0 (SAS, Institute Cary, NC, USA).ResultsNinety patients underwent LCP implantation (73 Micra and 17 Nanostim) with a median follow‐up duration of 62 (interquartile range 28‐169) days. Both groups had 100% successful device implant rates. There were no differences in procedure‐related major (0% vs 1%) or minor complications (8% vs 3%) in the LCP versus TVP groups (P > 0.05). Excluding Nanostim patients, there was a lower rate of device‐related revision or extraction in the Micra versus TVP groups (0% vs 5%, P = 0.028). Device endocarditis was more common in the TVP group (0% vs 3%, P = 0.04). Estimated longevity was greater for the LCP group (median 12.0 vs 10.0 years, P < 0.0001). An increase in severity of tricuspid valve regurgitation (TR) by ≥2 grades occurred in none of the LCP patients, and in 19% of the TVP patients (P = 0.017).ConclusionThere are no significant differences in procedural complications among patients receiving LCP versus TVP. The Micra group had lower rates of device‐related revision/extraction compared to the TVP group. Patients with leadless pacemaker were less likely to develop endocarditis or worsening TR.
Cardiac resynchronization therapy improves myocardial conduction
Yang, Mei , Li, Xuping , Li, Yi‐Gang , Zhou, Shenghua , Liang, Jinjun , Wu, Gang , Munoz, Freddy Del‐Carpio , Chen, Horng H. , Friedman, Paul A. , Cha, Yong‐Mei , Yang, Dachun, Del-Carpio Munoz, Freddy , Friedman, Paul A , Cha, Yong-Mei , Yang, Dachun, Zhou, Shenghua

Pacing and Clinical Electrophysiology | December 13, 2018 | Volume: 42 | Issue: 2 | Pages: 238-246

10.1111/pace.13581 Get It

AbstractBackgroundCardiac resynchronization therapy (CRT) reverses left ventricular remodeling and improves left ventricular systolic function. However, little is known about whether CRT improves ventricular conduction.ObjectiveTo determine the relationship between CRT response and QRS narrowing.MethodsThe study included consecutive patients who underwent CRT with defibrillator (CRT‐D) implantation between January 2002 and December 2012 and had subsequent generator replacement (GR). At the time of GR, super‐responder was defined as those who had left ventricular ejection fraction (LVEF) of 50% or more; patients who had an LVEF of 36–49% with an increase of more than 5% were considered responders, and the others were nonresponders. All patients were assessed 6 months after CRT‐D implantation and at the time of GR.ResultsOf 114 study patients, 58 (50.9%) were nonresponders, 29 (25.4%) responders, and 27 (23.7%) super‐responders. QRS narrowing at 6 months was significant in super‐responders (175.4 ± 21.4 to 159.7 ± 20.7 ms, P = 0.001) and responders (169.0 ± 21.3 to 157.7 ± 17.6 ms, P = 0.008). At time of GR, only super‐responders had further QRS narrowing (159.7 ± 20.7 to 146.3 ± 19.2 ms, P < 0.001). QRS duration change after 6 months was independently associated with super‐response (hazard ratio: 1.20 for every 5 ms QRS duration narrowing; 95% confidence interval, 1.06–1.38; P = 0.005), and QRS narrowing of 10 ms or more was associated with lower risk of all‐cause mortality after GR.ConclusionContinuous QRS narrowing after CRT, as an electrical marker, is associated with a super‐response to CRT. Further QRS narrowing 6 months after CRT implantation was associated with lower risk of mortality after GR.
Outcomes of repeated transvenous lead extraction
Fu, Hai‐Xia , Ho, Gordon , Yang, Mei , Huang, Xinmiao, Fender, Erin A. , Mulpuru, Siva K. , Asirvatham, Roshini, Friedman, Paul A. , Birgersdotter‐Green, Ulrika , Cha, Yong‐Mei , Fu, Haixia, Mulpuru, Siva, Friedman, Paul A , Cha, Yong-Mei , Pretorius, Victor

Pacing and Clinical Electrophysiology | July 30, 2018 | Volume: 41 | Issue: 10 | Pages: 1321-1328

10.1111/pace.13464 Get It

AbstractIntroductionThe outcomes of repeated cardiovascular implantable electronic device (CIED) lead extraction have not been well studied. We sought to determine the indications, outcomes, and safety of repeated lead extraction procedures.MethodsThis retrospective study was conducted using data from two medical centers, including 38 patients who had undergone two or more lead extraction procedures compared to 439 patients who had a single procedure. The electronic medical records and procedural databases were reviewed to determine the indications, procedural characteristics, and outcomes. The outcomes of the first procedure were compared to the outcomes of subsequent procedures.ResultsThe 5‐year cumulative probability of a repeated extraction procedure was 11% (95% confidence interval, 7%–15%). In 439 patients who underwent single lead extractions, 72% had device and lead related infections as the procedure indication compared to 39% for 38 patients who underwent repeated extraction (P < 0.001). The mean duration from device reimplant to repeated extraction procedures was 63 ± 48 months. Ninety‐eight percent of the leads were removed completely in repeated procedures, similar to the 95% success rate of the first procedure (P = 0.51). There was no significant difference in major complication rate in the first or repeated extractions (2.6% vs 5.2%, P = 0.79).ConclusionsRepeated transvenous lead extraction is not uncommon. It had a high success rate comparable to that of the initial procedure and was not associated with an increased incidence of adverse events.
Frequency of in‐hospital adverse outcomes and cost utilization associated with cardiac resynchronization therapy defibrillator implantation in the United States
Patel, Nilay , Viles-González, Juan F., Agnihotri, Kanishk, Arora, Shilpkumar , Patel, Nileshkumar , Aneja, Ekta, Shah, Mahek , Badheka, Apurva O., Pothineni, Naga Venkata K. , Kancharla, Krishna , Mulpuru, Siva K. , Cha, Yong‐Mei , Deshmukh, Abhishek , Pothineni, Naga Venkata , Mulpuru, Siva, Cha, Yong-Mei , Noseworthy, Peter A. , Kusumoto, Fred

Journal of Cardiovascular Electrophysiology | July 17, 2018 | Volume: 29 | Issue: 10 | Pages: 1425-1435

10.1111/jce.13701 Get It

AbstractBackground: The utilization of cardiac resynchronization therapy defibrillator (CRT‐D) has increased significantly, since its initial approval for use in selected patients with heart failure. Limited data exist as for current trends in implant‐related in‐hospital complications and cost utilization. The aim of our study was to examine in‐hospital complication rates associated with CRT‐D and their trends over the last decade.Methods and Results: Using the Nationwide Inpatient Sample, we estimated 378 248 CRT‐D procedures from 2003 to 2012. We investigated common complications, including mechanical, cardiovascular, pericardial complications (hemopericardium, cardiac tamponade, or pericardiocentesis), pneumothorax, stroke, vascular complications (consisting of hemorrhage/hematoma, incidents requiring surgical repair, and accidental arterial puncture), and in‐hospital deaths described with CRT‐D, defining them by the validated International Classification of Diseases, Ninth Revision, Clinical Modification diagnosis code. Mechanical complications (5.9%) were the commonest, followed by cardiovascular (3.6%), respiratory failure (2.4%), and pneumothorax (1.5%). Age (≥65 years), female gender (OR, 95% CI; P value) (1.08, 1.03‐1.13; 0.001), and the Charlson score ≥3 (1.52, 1.45‐1.60; <0.001) were significantly associated with increased mortality/complications.Conclusions: The overall complication rate in patients undergoing CRT‐D has been increasing in the last decade. Age (≥65), female sex, and the Charlson score ≥3 were associated with higher complications. In patients who underwent CRT‐D implantation, postoperative complications were associated with significant increases in cost.
Fragmentation of QRS complex during ventricular pacing is associated with ventricular arrhythmic events in patients with left ventricular dysfunction
Munoz, Freddy Del‐Carpio , Gharacholou, S. Michael , Cha, Yong‐Mei , Munger, Thomas M. , Friedman, Paul A. , Asirvatham, Samuel J. , Del-Carpio Munoz, Freddy , Cha, Yong-Mei , Friedman, Paul A , Asirvatham, Samuel J , Noseworthy, Peter A. , Scott, Christopher G. , Nkomo, Vuyisile T. , López-Jiménez, Francisco

Journal of Cardiovascular Electrophysiology | June 2, 2018 | Volume: 29 | Issue: 9 | Pages: 1248-1256

10.1111/jce.13656 Get It

AbstractBackgroundQRS fragmentation (fQRS) during baseline ventricular conduction, a myocardial fibrosis marker, is associated with increased risk of ventricular tachyarrhythmias but may not manifest unless ventricular activation change is provoked. We examined the association of fQRS during right ventricular (RV) pacing with death and ventricular tachyarrhythmia in patients with left ventricular (LV) dysfunction undergoing electrophysiology study (EPS).Methods and resultsStudy participants had LV dysfunction (ejection fraction < 50%) undergoing EPS from January 2002 to May 2014 at Mayo Clinic in Rochester, Minnesota. fQRS during RV stimulation involved >2 notches on R/S waves identified in ≥2 contiguous standard electrocardiographic leads representing anterior, inferior, or lateral ventricular segments. Primary outcomes were ventricular tachyarrhythmias that were symptomatic or required intervention and total and cardiac deaths. In all, 528 patients participated (mean age, 65 years; male sex, 80%). Of them, 312 (59%) had ischemic cardiomyopathy and mean (SD) left ventricular ejection fraction (LVEF) of 33.2% (9.5%); 457 (87%) had implantable cardiac devices (implanted defibrillator, n = 380). Mean (SD) follow‐up was 3.2 (3.0) years. fQRS during RV pacing was observed in 292 patients (60%) in any ventricular segment. Patients with fQRS during RV pacing had 2.5 higher rate of ventricular tachyarrhythmia events than patients with no fQRS (hazard ratio [95% CI], 2.45 [1.5–4.2]; P < 0.01), after correcting for baseline ventricular conduction defect and QRS duration, LVEF, inducible sustained ventricular tachycardia, diabetes mellitus, chronic kidney disease, and ischemic cardiomyopathy.ConclusionsRV stimulation can unmask fQRS, and it is associated with increased risk of ventricular tachyarrhythmia in LV dysfunction.
Outcomes of video‐assisted thoracoscopic surgery for transvenous lead extraction
Dai, Mingyan , Joyce, David L. , Friedman, Paul A. , Espinosa, Raúl E. , Osborn, Michael J., Huang, Congxin , Cha, Yong‐Mei , Blackmon, Shanda, Friedman, Paul A , Espinosa, Raul, Cha, Yong-Mei , Blackmon, Shanda

Journal of Cardiovascular Electrophysiology | June 2, 2018 | Volume: 29 | Issue: 7 | Pages: 1032-1037

10.1111/jce.13643 Get It

AbstractIntroductionTo evaluate the outcomes of video‐assisted thoracoscopic surgery (VATS) during transvenous lead extractions (TLEs).Methods and resultsNinety‐one high‐risk patients who underwent TLE in the operating room from January 1, 2015, to March 31, 2017, were included in the study. Of these, 9 patients underwent VATS during TLE. Their clinical characteristics, indications for lead extraction, and complications associated with TLE in the 9 patients who had VATS were compared with those for the 82 patients who did not have VATS. The mean (SD) age of the study patients was 61 (17) years (64.8% were male). The lead dwell time, number of leads extracted, and clinical comorbidities were similar between the 2 groups. Superior vena cava (SVC) tear occurred in 2 of the 9 patients in VATS group and in 1 of the 82 in the non‐VATS group (22.2% vs. 1.2%, P = 0.03). Of the 2 patients in the VATS group who had SVC tears, in 1 the tear was visualized immediately and there was no hemodynamic compromise. In the other patient, the SVC tear was within the pericardium; the blood pressure recovered quickly after sternotomy and repair. Both patients had complete lead extraction and survived hospitalization. The patient in the non‐VATS group who had an SVC tear had a successful repair but died of postoperative complications.ConclusionsUtilization of VATS to facilitate TLE is beneficial for early recognition of SVC tear and timely surgical repair in select high‐risk patients.