Back to Authors

Park, Soon J.

Mayo Clinic

Case Western Reserve University

Citations 22

Dual Anti-platelet Therapy After Coronary Artery Bypass Grafting: Is There Any Benefit? A Systematic Review and Meta-Analysis
Shah, Ishan K., Altarabsheh, Salah E. , Erwin, Patricia J., Boilson, Barry A. , Park, Soon J., Joyce, Lyle D., Deo, Salil V. , Dunlay, Shannon M. , Altarabsheh, Salah

Journal of Cardiac Surgery | March 15, 2013 | Volume: 28 | Issue: 2 | Pages: 109-116

10.1111/jocs.12074 Get It

Multiple Arterial Grafts Improve Late Survival of Patients Undergoing Coronary Artery Bypass Graft Surgery
Locker, Chaim, Schaff, Hartzell V. , Joyce, Lyle D., Park, Soon J., Burkhart, Harold M. , Suri, Rakesh M. , Greason, Kevin L. , Stulak, John M., Daly, Richard C. , Li, Zhuo , Dearani, Joseph A. , Li, Zhuo Ya , Schaff, Hartzell

Circulation | July 19, 2012 | Volume: 126 | Issue: 9 | Pages: 1023-1030

10.1161/circulationaha.111.084624 Get It

Background— Use of the left internal mammary artery (LIMA) in multivessel coronary artery disease improves survival after coronary artery bypass graft surgery; however, the survival benefit of multiple arterial (MultArt) grafts is debated. Methods and Results— We reviewed 8622 Mayo Clinic patients who had isolated primary coronary artery bypass graft surgery for multivessel coronary artery disease from 1993 to 2009. Patients were stratified by number of arterial grafts into the LIMA plus saphenous veins (LIMA/SV) group (n=7435) or the MultArt group (n=1187). Propensity score analysis matched 1153 patients. Operative mortality was 0.8% (n=10) in the MultArt and 2.1% (n=154) in the LIMA/SV ( P =0.005) group, which was not statistically different ( P =0.996) in multivariate analysis or the propensity-matched analysis ( P =0.818). Late survival was greater for MultArt versus LIMA/SV (10- and 15-year survival rates were 84% and 71% versus 61% and 36%, respectively [ P <0.001], in unmatched groups and 83% and 70% versus 80% and 60%, respectively [ P =0.0025], in matched groups). MultArt subgroups with bilateral internal mammary artery/SV (n=589) and bilateral internal mammary artery only (n=271) had improved 15-year survival (86% and 76%; 82% and 75% at 10 and 15 years [ P <0.001]), and patients with bilateral internal mammary artery/radial artery (n=147) and LIMA/radial artery (n=169) had greater 10-year survival (84% and 78%; P <0.001) versus LIMA/SV. In multivariate analysis, MultArt grafts remained a strong independent predictor of survival (hazard ratio, 0.79; 95% confidence interval, 0.66–0.94; P =0.007). Conclusions— In patients undergoing isolated coronary artery bypass graft surgery with LIMA to left anterior descending artery, arterial grafting of the non–left anterior descending vessels conferred a survival advantage at 15 years compared with SV grafting. It is still unproven whether these results apply to higher-risk subgroups of patients.
Iatrogenic Aortic Dissection … or Intramural Hematoma?
Welch, Terrence D., Foley, Thomas A. , Barsness, Gregory W. , Spittell, Peter C., Tilbury, R. Thomas, Enriquez‐Sarano, Maurice , Evangelista, Artur , Park, Soon J., Michelena, Héctor I. , Enriquez-Sarano, Maurice

Circulation | March 6, 2012 | Volume: 125 | Issue: 9 | Pages: No page available

10.1161/circulationaha.111.056937 Get It

Outcomes in Advanced Heart Failure Patients With Left Ventricular Assist Devices for Destination Therapy
Park, Soon J., Milano, Carmelo A. , Tatooles, Antone, Rogers, Joseph G. , Adamson, Robert, Steidley, D. Eric , Ewald, Gregory A. , Sundareswaran, Kartik S., Farrar, David J. , Slaughter, Mark S.

Circulation: Heart Failure | January 27, 2012 | Volume: 5 | Issue: 2 | Pages: 241-248

10.1161/circheartfailure.111.963991 Get It

Background— The HeartMate II (HMII) destination therapy (DT) trial demonstrated significant improvements in outcomes in continuous-flow left ventricular assist devices compared with patients implanted with the pulsatile-flow HeartMate XVE. The primary hypothesis of the current study is that trial patients enrolled after the initial data cohort would have better clinical outcomes. Methods and Results— Two hundred eighty-one patients who underwent HMII for DT from May 2007 to March 2009 (Mid Trial [MT] group) were compared with the initial 133 HMII patients from March 2005 to May 2007 (Early Trial [ET] group). Patient entry criteria were the same during the 2 time periods. Survival, adverse events, and quality of life were compared between the 2 groups. Baseline characteristics were similar between the groups. Compared with the ET group, patients in the MT group had reduced adverse event rates for bleeding requiring transfusions (1.66 versus 1.13 events per patient-year, P <0.001), sepsis (0.38 versus 0.27, P =0.025), device-related infections (0.47 versus 0.27, P <0.001), and hemorrhagic stroke (0.07 versus 0.03, P =0.01). Other event rates were similar between groups including ischemic stroke (0.06 versus 0.05 events per patient-year, P =0.57). Survival at 1 year in the MT group was 73% versus 68% in the ET group ( P =0.21). Additionally, there was a significant reduction in deaths caused by hemorrhagic stroke ( P =0.01). Quality of life improvements were significant in both the groups ( P <0.001). Conclusions— The benefit of DT therapy with the HMII is confirmed in subsequent trial patients, with improved adverse event rates and a strong trend for improvements in survival. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00121485.
Sirolimus as Primary Immunosuppression Attenuates Allograft Vasculopathy With Improved Late Survival and Decreased Cardiac Events After Cardiac Transplantation
Topilsky, Yan , Hasin, Tal , Raichlin, Eugenia , Boilson, Barry A. , Schirger, John A., Pereira, Naveen L. , Edwards, Brooks S., Clavell, Alfredo L. , Rodeheffer, Richard J. , Frantz, Robert P. , Maltais, Simon, Park, Soon J., Daly, Richard C. , Kushwaha, Sudhir S. , Lerman, Amir , Frantz, Robert P , Topilsky, Yan

Circulation | December 30, 2011 | Volume: 125 | Issue: 5 | Pages: 708-720

10.1161/circulationaha.111.040360 Get It

Background— We retrospectively analyzed the potential of sirolimus as a primary immunosuppressant in the long-term attenuation of cardiac allograft vasculopathy progression and the effects on cardiac-related morbidity and mortality. Methods and Results— Forty-five cardiac transplant recipients were converted to sirolimus 1.2 years (0.2, 4.0) after transplantation with complete calcineurin inhibitor withdrawal. Fifty-eight control subjects 2.0 years (0.2, 6.5 years) from transplantation were maintained on calcineurin inhibitors. Age, sex, ejection fraction, and time from transplantation to baseline intravascular ultrasound study were not different ( P >0.2 for all) between the groups; neither were secondary immunosuppressants and use of steroids. Three-dimensional intravascular ultrasound studies were performed at baseline and 3.1 years (1.3, 4.6 years) later. Plaque index progression (plaque volume/vessel volume) was attenuated in the sirolimus group (0.7±10.5% versus 9.3±10.8%; P =0.0003) owing to reduced plaque volume in patients converted to sirolimus early (<2 years) after transplantation ( P =0.05) and improved positive vascular remodeling ( P =0.01) in patients analyzed late (>2 years) after transplantation. Outcome analysis in 160 consecutive patients maintained on 1 therapy was performed regardless of performance of intravascular ultrasound examinations. Five-year survival was improved with sirolimus (97.4±1.8% versus 81.8±4.9%; P =0.006), as was freedom from cardiac-related events (93.6±3.2% versus 76.9±5.5%; P =0.002). Conclusions— Substituting calcineurin inhibitor with sirolimus as primary immunosuppressant attenuates long-term cardiac allograft vasculopathy progression and may improve long-term allograft survival owing to favorable coronary remodeling. Because of the lack of randomization and retrospective nature of our analysis, the differences in outcome should be interpreted cautiously, and prospective clinical trials are required.
The Off-Pump Implantation of an Apicoaortic Valved Graft is Safe and Has No Negative Impact on Coronary Flow and Hemodynamics
Karapanos, N. Tsirikos, Suddendorf, Scott H., Li, Zhuo , Huebner, Marianne , Park, Soon J., Joyce, Lyle D., Daly, Richard C.

Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery | October 28, 2011 | Volume: 6 | Issue: 5 | Pages: 298-304

10.1097/imi.0b013e31823735ba Get It

Objective To determine the hemodynamic effect of an off-pump Apicoaortic valved graft (AAVG) implantation, we performed a quantitative coronary flow analysis in a swine model of severe aortic stenosis. Methods In 10 swine, cardiac output, coronary flow, right common carotid artery flow, and internal mammary artery flow were measured along with left and right ventricular pressures and aortic and pulmonary artery pressures. A novel AAVG was implanted off-pump on the left ventricular (LV) apex using a specially designed implantation tool and anastomosed to the descending thoracic aorta. Aortic flow was measured proximally and distally of the AAVG-to-descending thoracic aorta anastomosis. After AAVG implantation, epicardial echo confirmed occlusion of the LV outflow tract by a valvuloplasty balloon. Baseline simultaneous measurements of all parameters were repeated after AAVG implantation and intravenous Dobutamine administration. Results The AAVG was implanted without any blood loss. After AAVG implantation and LV outflow tract occlusion, the aortic flow proximal to the AAVG-to-descending thoracic aorta anastomosis changed from antegrade (1508 ± 435 mL/min) to retrograde (–529 ± 241 mL/min, P < 0.001). All other measured parameters remained unchanged compared with baseline. After intravenous Dobutamine administration, LV pressure increased from 88 ± 20 to 184 ± 36 mm Hg (+209%, P < 0.0001) and coronary flow increased from 75 ± 34 to 193 ± 90 mL/min (+257%, P = 0.001). Conclusions The off-pump implantation of an AAVG is bloodless, safe, reproducible and has no negative impact on coronary flow and hemodynamics. In addition, to the best of our knowledge, this is the first study where blood flow in all coronary arteries was measured simultaneously during an AAVG implantation.
Echocardiographic Variables After Left Ventricular Assist Device Implantation Associated With Adverse Outcome
Topilsky, Yan , Hasin, Tal , Oh, Jae K. , Borgeson, Daniel D., Boilson, Barry A. , Schirger, John A., Clavell, Alfredo L. , Frantz, Robert P. , Tsutsui, Rayji , Liu, Mingya, Maltais, Simon, Kushwaha, Sudhir S. , Pereira, Naveen L. , Park, Soon J., Frantz, Robert P , Topilsky, Yan

Circulation: Cardiovascular Imaging | September 22, 2011 | Volume: 4 | Issue: 6 | Pages: 648-661

10.1161/circimaging.111.965335 Get It

Background— Operative mortality after left ventricular assist device (LVAD) implantation is heavily influenced by patient selection and the technical difficulty of surgery. However, how we treat our patients and LVAD setting may affect the patient outcome beyond this period. We postulated that the presence of echocardiographic variables 1 month after surgery suggesting appropriate degree of LV unloading and an adequate forward flow would be important in determining clinical outcomes after the initial successful LVAD implantation. Methods and Results— We retrospectively analyzed various variables in echocardiographic examinations performed 30 days after LVAD implant in 76 consecutive patients receiving continuous flow device for their association with a compound end point (90-day mortality, readmission for heart failure, or New York Heart Association class III or higher at the end of the 90-day period). The echocardiographic associations examined included estimated LVAD flow, with and without native LV contribution, interventricular septal position, the status of aortic valve opening, an estimated left atrial pressure (ELAP), the mitral flow E-wave deceleration time, and the ratio of deceleration time to E-wave velocity (mitral deceleration index [MDI]). Four patients died during the 30- to 90-day period, 6 patients were readmitted for heart failure, and 25 patients were considered to have New York Heart Association class III or higher at the end of the 90-day period. Variables associated with adverse outcome included increased ELAP (odds ratio, 1.30 [1.16–1.48]; P <0.0001), MDI <2 ms/[cm/s] (odds ratio, 4.4 implantation [1.22–18]; P =0.02) and decreased tricuspid lateral annulus velocity (odds ratio, 0.70 implantation [0.48–0.95]; P =0.02). A leftward deviation of interventricular septum was associated with a worse outcome (odds ratio, 3.03 implantation [1.21–13.3]; P =0.01). Conclusions— Mortality and heart failure after LVAD surgery appear to be predominantly determined by echocardiographic evidence of inefficient unloading of the left ventricle and persistence of right ventricular dysfunction. Increased estimated LA pressure and short MDI are associated with worse mid term outcome. Leftward deviation of the septum is associated with worse outcome as well.
Aortic Valve Replacement in the Elderly
Ashikhmina, Elena, Schaff, Hartzell V. , Sundt, Thoralf M. , Suri, Rakesh M. , Park, Soon J., Burkhart, Harold M. , Daly, Richard C. , Li, Zhuo , Dearani, Joseph A. , Li, Zhuo , Schaff, Hartzell

Circulation | August 9, 2011 | Volume: 124 | Issue: 9 | Pages: 1070-1078

10.1161/circulationaha.110.987560 Get It

Background— Few data exist on long-term outcomes of elderly patients after aortic valve replacement. We evaluated latest follow-up information for patients ≥70 years of age after aortic valve replacement. Methods and Results— Late overall survival of 2890 consecutive patients ≥70 years of age who underwent aortic valve replacement between January 1993 and December 2007 was reviewed retrospectively, analyzed, and stratified by preoperative and intraoperative variables. Observed 5-, 10-, and 15-year late postoperative survival was lower than generally expected (68%, 34%, and 8% versus 70%, 42%, and 20%, respectively; P <0.001). Independent predictors of late death included older age, renal failure, diabetes mellitus, stroke, myocardial infarction, immunosuppression, prior coronary artery bypass grafting, implanted pacemaker, lower ejection fraction, hypertension, and New York Heart Association class III or IV. After stratification by age–comorbidity risk score, 10-year survival for the lowest-risk group (n=946 [33%]) was similar to expected survival (55% versus 55%; P =0.50), but for the highest-risk group (n=564 [20%]), survival was significantly lower than expected (9% versus 26%; P <0.001). For 229 pairs of propensity-matched patients with mechanical or biological prostheses, survival was not significantly different (67%, 40%, and 19% versus 71%, 45%, and 7% at 5, 10, and 15 years, respectively; P =0.81). Structural deterioration of bioprostheses occurred in 64 patients (2.4%). Conclusions— Survival of elderly patients after aortic valve replacement is influenced by age and preoperative comorbidities; 33% at lowest risk had overall survival similar to that of an age- and sex-matched general population. There was no sufficient evidence that valve type affected survival. Structural deterioration of aortic bioprostheses was rare.
Preoperative Factors Associated With Adverse Outcome After Tricuspid Valve Replacement
Topilsky, Yan , Khanna, Amber , Oh, Jae K. , Enriquez‐Sarano, Maurice , Jeon, Yang Bin , Sundt, Thoralf M. , Schaff, Hartzell V. , Park, Soon J., Nishimura, Rick A. , Enriquez-Sarano, Maurice , Khanna, Amber D , Schaff, Hartzell , Topilsky, Yan

Circulation | April 26, 2011 | Volume: 123 | Issue: 18 | Pages: 1929-1939

10.1161/circulationaha.110.991018 Get It

Background— Preoperative factors associated with increased mortality and worse outcome after tricuspid valve replacement in patients with severe tricuspid regurgitation are poorly understood. Methods and Results— We retrospectively analyzed 189 patients (37% men; age, 67.5±11.3 years) who underwent tricuspid valve replacement for severe tricuspid regurgitation. Operative mortality rate was 10%, and was associated with intra-aortic balloon pump (odds ratio, 3.2; 95% confidence interval, 1.9 to 5.6; P <0.0001) or the presence of severe symptoms (New York Heart Association class IV relative to classes II and/or III) at the time of surgery (1.7; 95% confidence interval, 1.05 to 2.8; P =0.02). At the end of follow-up (29.3±27.1 months), 70 patients (37%) died, 6 (3%) needed tricuspid reoperation, and 41 (21.7%) were readmitted for heart failure. Seventy-eight patients (41.3%) were free from cardiovascular events (death, tricuspid reoperation, or heart failure admissions). The only echocardiographic parameter independently associated with adverse outcomes was a decrease in the right index of myocardial performance ratio. All-cause mortality was independently associated with a higher Charlson index (hazard ratio, 1.18; 95% confidence interval, 1.01 to 1.36; P =0.03), shorter right index of myocardial performance ratio (0.91; 95% confidence interval, 0.87 to 0.96; P =0.005), and preoperative New York Heart Association IV class (1.71; 95% confidence interval, 1.3 to 2.2; P <0.0001). In 68 patients with isolated tricuspid valve replacement, the associations between short right index of myocardial performance ratio, high Charlson index, New York Heart Association class IV, and increased mortality remained significant. Conclusions— Tricuspid valve replacement for severe tricuspid regurgitation can be performed with an acceptable operative mortality if patients undergo surgery before the onset of advanced heart failure symptoms. Late mortality is associated with a high preoperative Charlson index, short right index of myocardial performance ratio, and advanced New York Heart Association class.
Application of Computer Modeling in Systemic VAD Support of Failing Fontan Physiology
Durham, Lucian A. , Burkhart, Harold M. , Joyce, Lyle D., Cetta, Frank , Phillips, Sabrina D. , Sundareswaran, Kartik S., Farrar, David J. , Park, Soon J., Dearani, Joseph A. , Cabalka, Allison K.

World Journal for Pediatric and Congenital Heart Surgery | April 13, 2011 | Volume: 2 | Issue: 2 | Pages: 243-248

10.1177/2150135110397386 Get It

Although the Fontan procedure has been enormously successful in palliation of single-ventricle patients, many seem to experience progressive failure of the Fontan circulation over time. Ventricular assist devices (VADs) have developed into stable platforms for long-term support of adult patients with heart failure. Given the success of axial flow devices, it was hypothesized that the technology could provide clinical benefit to failing Fontan patients. The aim of this study was to use a computer model to evaluate VAD support in failing Fontan physiology. A computer model of Fontan circulation with heart failure was developed and the HeartMate II (HM II) (Thoratec Corp) axial flow ventricular assist device was connected to this model in a systemic configuration to examine its impact. Cardiac catheterization data from 7 patients (8 catheterization studies) with failing Fontan physiology were applied to this model to evaluate the impact of using the HM II in this manner. When the HM II was used in a systemic configuration at 8000 rpm, there was a 35% decrease in the systemic venous pressure in the Fontan circuit and a 63% decrease in pulmonary capillary wedge pressure with a resultant 41% increase in CI. The model also predicted patient-specific parameters where the VAD may not benefit the patient, such as fixed elevated pulmonary vascular resistance, low systemic ventricular end-diastolic pressure, and high unresponsive systemic vascular resistance. These data suggest a potential benefit from application of axial flow VAD technology in the management of failing Fontan physiology. Clinical correlation will allow for refinement of this model as a predictive tool in discerning which patients may benefit from placement of a VAD and what issues must be addressed prior to implanting the device.