Back to Authors

Sun, Yuanqi

https://orcid.org/0000-0001-5481-7380

Mayo Clinic

Kennedy Krieger Institute

Citations 6

Imaging solute transportation along the posterior lymphatic pathway in the ocular glymphatic system in healthy human participants
Wen, Xuehua , Sun, Yuanqi, Li, Yinghao, Paez, Adrian , Varghese, Jacob , Knutsson, Linda, Zijl, Peter C.M. Van, Graley, Christina R, Bakker, Arnold, Ward, Bryan K., Kashani, Amir H. , Sun, Yuanqi , Zhou, Xinyi Yedda , Li, Yinghao , Varghese, Jacob, Pillai, Jay J. , Knutsson, Linda , Zijl, Peter C.M. van , Leigh, Richard J. , Kamson, David , Saidha, Shiv , Bakker, Arnold , Ward, Bryan Kevin

No container title available | April 9, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.64898/2026.04.03.26349283 Get It

Abstract Background Recently, a posterior pathway for fluid drainage from the retina to the meningeal lymphatics in the optic nerve (ON) sheath was identified in rodents using intravitreal imaging tracers directly injected into the ocular-globe. Fluid and solute clearance along this pathway may be associated with many diseases. However, intravitreal tracers are rarely used in clinical imaging. As intravenous Gadolinium-based-contrast-agent (GBCA) can enter the globe via the blood-ocular-barriers, it may provide an alternative approach to image this pathway. Purpose To establish a clinically feasible intravenous GBCA-based MRI approach for tracking fluid and solute transport along the posterior lymphatic pathway in the ocular glymphatic system. Materials&Methods This prospective study was conducted from March 2021 to September 2022 in healthy participants. Dynamic-susceptibility-contrast-in-the-CSF (cDSC) MRI was performed before, immediately and 4 hours after intravenous-GBCA administration to track GBCA distribution in aqueous humor (AH) and cerebrospinal fluid (CSF) in regions-of-interest (ROIs) in the globe (anterior-cavity, vitreous-body), in the intraorbital and extraorbital ON, and in the intracranial CSF space proximal to the ON (chiasmatic-cistern, interpeduncular-cistern). Kruskal–Wallis tests with post-hoc Dunn’s tests were used for group comparisons. Results Sixteen healthy participants (mean age±SD: 51±21 years, 5 men) were recruited. Intravenous-GBCA enhancement was observed in all ROIs immediately after injection. At 4-hour-post-GBCA, the vitreous body showed a trend of smaller enhancement area (55±11% versus 49±11%, P =.14) and lower GBCA-concentration (0.044±0.014 versus 0.028±0.010 mmol/L, P =.07) compared to immediate-post-GBCA. The intraorbital ON showed more widespread enhancement (39±5% versus 59±6%, P =.01) and significantly higher GBCA-concentration (0.023±0.009 versus 0.059±0.015 mmol/L, P <.001) at 4-hour-post-GBCA. Conclusion Dynamic fluid and solute transportation along the posterior lymphatic pathway in the ocular glymphatic system in healthy participants was measured by tracking intravenous-GBCAs entering the globe via the blood-ocular-barriers using cDSC-MRI. Summary Statement Dynamic fluid and solute transportation along the posterior lymphatic pathway in the ocular glymphatic system in healthy participants was measured by tracking intravenous-Gadolinium-based-contrast-agents entering ocular-globe via blood-ocular-barriers using dynamic-susceptibility-contrast-in-the-CSF (cDSC)-MRI. Key Results In this prospective study of sixteen participants, Gadolinium-based-contrast-agent (GBCA)-induced signal changes were detected in the aqueous-humor and cerebrospinal fluid immediately following intravenous administration using dynamic-susceptibility-contrast-in-the-CSF (cDSC)-MRI. At 4-hour-post-GBCA, the vitreous-body showed a trend of smaller enhancement area (55±11% versus 49±11%, P =.14) and lower GBCA-concentration (0.044±0.014 versus 0.028±0.010 mmol/L, P =.07) compared to immediate-post-GBCA. The intraorbital-optic-nerve showed more widespread enhancement (39±5% versus 59±6%, P =.01) and higher GBCA-concentration (0.023±0.009 versus 0.059±0.015 mmol/L, P <.001) at 4-hour-post-GBCA.
Dynamic MRI of Fluid and Solute Transportation across the Arachnoid Barrier in the Human Meninges
Li, Yinghao , Sun, Yuanqi, Paez, Adrian , Xu, Gaoqiang , Pillai, Jay J. , Iliff, Jeffrey J., Ganji, Sandeep , Knutsson, Linda, Zijl, Peter C. M. Van, Calabresi, Peter A., Sun, Yuanqi , Knutsson, Linda , Sun, Yang-bai , Sun, Yuanqi , Iliff, Jeffrey , Ganji, Sandeep K , Knutsson, Linda , Calabresi, Peter A , Hua, Jun , Pillai, Jay J , Iliff, Jeffrey J. , Zijl, Peter C.M. van , Kamson, David , Calabresi, Peter A.

Radiology | February 24, 2026 | Volume: 318 | Issue: 2 | Pages: No page available

10.1148/radiol.252393 Get It

Dynamic fluid and solute transportation across the arachnoid barrier in the meninges of healthy participants was measured by tracking intravenous gadolinium-based contrast agent entering cerebrospinal fluid from dural blood vessels using dynamic dual-spin-echo perfusion MRI.
Imaging arterial and venous vessels using Iron Dextran enhanced multi‐echo 3D gradient echo MRI at 7T
Li, Yinghao , Li, Wei , Paez, Adrian , Cao, Di , Sun, Yang-bai , Gu, Chunming , Miao, Xinyuan , Li, Wenbo , Pillai, Jay J. , Earley, Christopher J. , Sun, Yuanqi , Sun, Yuanqi , Li, Xu , Hua, Jun , Pillai, Jay J , Zhang, Kaihua , Liu, Peiying , Lu, Hanzhang , Zijl, Peter C.M. van , Li, Xu

NMR in Biomedicine | August 26, 2024 | Volume: 37 | Issue: 12 | Pages: No page available

10.1002/nbm.5251 Get It

AbstractIron Dextran is a widely used iron oxide compound to treat iron‐deficiency anemia patients in the clinic. Similar to other iron oxide compounds such as Ferumoxytol, it can also be used off‐label as an intravascular magnetic resonance imaging (MRI) contrast agent due to its strong iron‐induced T2 and T2* shortening effects. In this study, we seek to evaluate the feasibility of using Iron Dextran enhanced multi‐echo susceptibility weighted imaging (SWI) MRI at 7T to image arterial and venous blood vessels in the human brain. Phantom experiments were performed to measure the r2* relaxivity for Iron Dextran in blood, based on which the SWI sequence was optimized. Pre‐ and post‐infusion MR images were acquired in human subjects from which maps of arteries and veins were extracted. The post‐contrast SWI images showed enhanced susceptibility difference between blood and the surrounding tissue in both arteries and veins. Our results showed that the proposed Iron Dextran enhanced multi‐echo SWI approach allowed the visualization of blood vessels with diameters down to ~100 μm, including small blood vessels supplying and draining small brain structures such as the hippocampus. We conclude that Iron Dextran can be an alternative iron‐based MRI contrast agent for blood vessel imaging in the human brain.
On the optimization of 3D inflow‐based vascular‐space‐occupancy (iVASO) MRI for the quantification of arterial cerebral blood volume (CBVa)
Gu, Chunming , Li, Yinghao , Cao, Di , Miao, Xinyuan , Paez, Adrian , Sun, Yuanqi, Cai, Jitong, Li, Wenbo , Pillai, Jay J. , Earley, Christopher J. , Sun, Yuanqi , Pillai, Jay J , Gu, Chunming , Li, Xu , Zijl, Peter C.M. van

Magnetic Resonance in Medicine | December 20, 2023 | Volume: 91 | Issue: 5 | Pages: 1893-1907

10.1002/mrm.29971 Get It

AbstractPurposeThe inflow‐based vascular‐space‐occupancy (iVASO) MRI was originally developed in a single‐slice mode to measure arterial cerebral blood volume (CBVa). When vascular crushers are applied in iVASO, the signals can be sensitized predominantly to small pial arteries and arterioles. The purpose of this study is to perform a systematic optimization and evaluation of a 3D iVASO sequence on both 3 T and 7 T for the quantification of CBVa values in the human brain.MethodsThree sets of experiments were performed in three separate cohorts. (1) 3D iVASO MRI protocols were compared to single‐slice iVASO, and the reproducibility of whole‐brain 3D iVASO MRI was evaluated. (2) The effects from different vascular crushers in iVASO were assessed. (3) 3D iVASO MRI results were evaluated in arterial and venous blood vessels identified using ultrasmall‐superparamagnetic‐iron‐oxides–enhanced MRI to validate its arterial origin.Results3D iVASO scans showed signal‐to‐noise ratio (SNR) and CBVa measures consistent with single‐slice iVASO with reasonable intrasubject reproducibility. Among the iVASO scans performed with different vascular crushers, the whole‐brain 3D iVASO scan with a motion‐sensitized‐driven‐equilibrium preparation with two binomial refocusing pulses and an effective TE of 50 ms showed the best suppression of macrovascular signals, with a relatively low specific absorption rate. When no vascular crusher was applied, the CBVa maps from 3D iVASO scans showed large CBVa values in arterial vessels but well‐suppressed signals in venous vessels.ConclusionA whole‐brain 3D iVASO MRI scan was optimized for CBVa measurement in the human brain. When only microvascular signals are desired, a motion‐sensitized‐driven‐equilibrium–based vascular crusher with binomial refocusing pulses can be applied in 3D iVASO.
Concurrent measurement of perfusion parameters related to small blood vessels and cerebrospinal fluid circulation in the human brain using dynamic dual‐spin‐echo perfusion MRI
Cao, Di , Sun, Yuanqi , Li, Yinghao , Pillai, Jay J. , Qiao, Ye , Knutsson, Linda , Sun, Yang-bai , Su, Pan , Knutsson, Linda , Pillai, Jay J , Sun, Yuanqi , Hua, Jun , Lu, Hanzhang , Zijl, Peter C.M. van

NMR in Biomedicine | June 12, 2023 | Volume: 36 | Issue: 10 | Pages: No page available

10.1002/nbm.4984 Get It

AbstractAccumulating evidence from recent studies has indicated the importance of studying the interaction between the microvascular and lymphatic systems in the brain. To date, most imaging methods can only measure blood or lymphatic vessels separately, such as dynamic susceptibility contrast (DSC) MRI for blood vessels and DSC MRI‐in‐the‐cerebrospinal fluid (CSF) (cDSC MRI) for lymphatic vessels. An approach that can measure both blood and lymphatic vessels in a single scan offers advantages such as a halved scan time and contrast dosage. This study attempts to develop one such approach by optimizing a dual‐echo turbo‐spin‐echo sequence, termed “dynamic dual‐spin‐echo perfusion (DDSEP) MRI”. Bloch simulations were performed to optimize the dual‐echo sequence for the measurement of gadolinium (Gd)‐induced blood and CSF signal changes using a short and a long echo time, respectively. The proposed method furnishes a T1‐dominant contrast in CSF and a T2‐dominant contrast in blood. MRI experiments were performed in healthy subjects to evaluate the dual‐echo approach by comparing it with existing separate methods. Based on simulations, the short and long echo time were chosen around the time when blood signals show maximum difference between post‐ and pre‐Gd scans, and the time when blood signals are completely suppressed, respectively. The proposed method showed consistent results in human brains as previous studies using separate methods. Signal changes from small blood vessels occurred faster than from lymphatic vessels after intravenous Gd injection. In conclusion, Gd‐induced signal changes in blood and CSF can be detected simultaneously in healthy subjects with the proposed sequence. The temporal difference in Gd‐induced signal changes from small blood and lymphatic vessels after intravenous Gd injection was confirmed using the proposed approach in the same human subjects. Results from this proof‐of‐concept study will be used to further optimize DDSEP MRI in subsequent studies.