Algeciras-Schimnich, Alicia

0000-0002-4455-6217

Mayo Clinic

Mayo Clinic

Citations 25

P‐tau/Aβ42 and Aβ42/40 ratios in CSF are equally predictive of amyloid PET status
Campbell, Michelle R. , Ashrafzadeh‐Kian, Susan , Petersen, Ronald C. , Syrjanen, Jeremy A. , Harten, Argonde C. van , Lowe, Val J. , Bornhorst, Joshua A. , van Harten, Argonde C, Algeciras-Schimnich, Alicia , Bornhorst, Joshua , Mielke, Michelle M. , Jack, Clifford R. , Algeciras‐Schimnich, Alicia

Alzheimer's & Dementia: Diagnosis, Assessment & Disease Monitoring | May 18, 2021 | Volume: 13 | Issue: 1 | Pages: No page available

10.1002/dad2.12190 Get It

Abstract Introduction Measurement of amyloid beta (Aβ40 and Aβ42) and tau (phosphorylated tau [p‐tau] and total tau [t‐tau]) in cerebrospinal fluid (CSF) can be utilized to differentiate clinical and preclinical Alzheimer's disease dementia (AD) from other neurodegenerative processes. Methods CSF biomarkers were measured in 150 participants from the Mayo Clinic Study of Aging and the Alzheimer's Disease Research Center. P‐tau/Aβ42 (Roche Elecsys, Fujirebio LUMIPULSE) and Aβ42/40 (Fujirebio LUMIPULSE) ratios were compared to one another and to amyloid positron emission tomography (PET) classification. Results Strong correlation was observed between LUMIPULSE p‐tau/Aβ42 and Aβ42/40, as well as Elecsys and LUMIPULSE p‐tau/Aβ42 and Aβ42/40 (Spearman's ρ = –0.827, –0.858, and 0.960, respectively). Concordance between LUMIPULSE p‐tau/Aβ42 and Aβ42/40 was 96% and between Elecsys p‐tau/Aβ42 and both LUMIPULSE ratios was 97%. All ratios had > 94% overall, positive, and negative percent agreement with amyloid PET classification. Discussion These data suggest that p‐tau/Aβ42 and Aβ42/40 ratios provide similar clinical information in the assessment of amyloid pathology.
Current and Emerging Multianalyte Assays with Algorithmic Analyses—Are Laboratories Ready for Clinical Adoption?
Colón-Franco, Jessica M , Bossuyt, Patrick M M, Algeciras-Schimnich, Alicia , Engstrom-Melnyk, Julia, Fleisher, Martin, Kattan, Michael W. , Bossuyt, Patrick M M, Bird, Chris , Lambert-Messerlian, Geralyn M. , Kattan, Michael W

Clinical Chemistry | January 17, 2018 | Volume: 64 | Issue: 6 | Pages: 885-891

10.1373/clinchem.2017.275677 Get It

Glycoprotein 120 Binding to CXCR4 Causes p38-Dependent Primary T Cell Death That Is Facilitated by, but Does Not Require Cell-Associated CD4
Trushin, Sergey A., Algeciras-Schimnich, Alicia , Vlahakis, Stacey R., Bren, Gary D., Warren, Sarah, Schnepple, David, Badley, Andrew D. , Badley, Andrew D

The Journal of Immunology | April 18, 2014 | Volume: 178 | Issue: 8 | Pages: 4846-4853

10.4049/jimmunol.178.8.4846 Get It

Abstract HIV-1 infection causes the depletion of host CD4 T cells through direct and indirect (bystander) mechanisms. Although HIV Env has been implicated in apoptosis of uninfected CD4 T cells via gp120 binding to either CD4 and/or the chemokine receptor 4 (CXCR4), conflicting data exist concerning the molecular mechanisms involved. Using primary human CD4 T cells, we demonstrate that gp120 binding to CD4 T cells activates proapoptotic p38, but does not activate antiapoptotic Akt. Because ligation of the CD4 receptor alone or the CXCR4 receptor alone causes p38 activation and apoptosis, we used the soluble inhibitors, soluble CD4 (sCD4) or AMD3100, to delineate the role of CD4 and CXCR4 receptors, respectively, in gp120-induced p38 activation and death. sCD4 alone augments gp120-induced death, suggesting that CXCR4 signaling is principally responsible. Supporting that model, AMD3100 reduces death caused by gp120 or by gp120/sCD4. Finally, prevention of gp120-CXCR4 interaction with 12G5 Abs blocks p38 activation and apoptosis, whereas inhibition of CD4-gp120 interaction with Leu-3a has no effect. Consequently, we conclude that gp120 interaction with CXCR4 is required for gp120 apoptotic effects in primary human T cells.
Failure of Current Laboratory Protocols to Detect Lot-to-Lot Reagent Differences: Findings and Possible Solutions
Algeciras‐Schimnich, Alicia , Bruns, David E., Boyd, James C. , Bryant, Sandra C. , Fortune, Kristin La , Grebe, Stefan K., Algeciras-Schimnich, Alicia

Clinical Chemistry | April 17, 2013 | Volume: 59 | Issue: 8 | Pages: 1187-1194

10.1373/clinchem.2013.205070 Get It

BACKGROUND Maintaining consistency of results over time is a challenge in laboratory medicine. Lot-to-lot reagent changes are a major threat to consistency of results. METHODS For the period October 2007 through July 2012, we reviewed lot validation data for each new lot of insulin-like growth factor 1 (IGF-1) reagents (Siemens Healthcare Diagnostics) at Mayo Clinic, Rochester, MN, and the University of Virginia, Charlottesville, VA. Analyses of discarded patient samples were used for comparison of lots. For the same period, we determined the distributions of reported patient results for each lot of reagents at the 2 institutions. RESULTS Lot-to-lot validation studies identified no reagent lot as significantly different from the preceding lot. By contrast, significant lot-to-lot changes were seen in the means and medians of 105 668 reported patient IGF-I results during the period. The frequency of increased results increased nearly 2-fold to a high of 17%, without detectable changes in the underlying patient demographics. Retrospective statistical analysis indicated that lot-to-lot comparison protocols were underpowered and that validation studies for this assay required testing >100 samples to achieve 90% power to detect reagent lots that would significantly alter the distributions of patient results. CONCLUSIONS The number of test samples required for adequate lot-to-lot validation protocols is high and may be prohibitively large, especially for low-volume or complex assays. Monitoring of the distributions of patient results has the potential to detect lot-to-lot inconsistencies relatively quickly. We recommend that manufacturers implement remote monitoring of patient results from analyzers in multiple institutions to allow rapid identification of between-lot result inconsistency.
Evaluation of the PAX8/PPARG Translocation in Follicular Thyroid Cancer with a 4-Color Reverse-Transcription PCR Assay and Automated High-Resolution Fragment Analysis
Algeciras-Schimnich, Alicia , McIver, Bryan, Flynn, Heather C., Eberhardt, Norman L., Grebe, Stefan K., Milošević, Dragana , Reddi, Honey V.

Clinical Chemistry | January 7, 2010 | Volume: 56 | Issue: 3 | Pages: 391-398

10.1373/clinchem.2009.134015 Get It

Abstract Background: Molecular testing of thyroid malignancies, in combination with cytologic and histologic examination, is becoming increasingly attractive as a tool for refining traditional morphologic diagnosis. The molecular changes associated with follicular thyroid carcinoma (FTC) are point mutations in RAS oncogenes or the presence of PAX8/PPARG (paired box 8/peroxisome proliferator-activated receptor gamma) rearrangement. Methods: We developed and validated a clinical assay for the detection of PAX8/PPARG rearrangements that uses a 4-color reverse-transcription PCR (RT-PCR) assay and high-resolution fragment analysis. Results: The RT-PCR assay is applicable for detecting the various described fusion transcripts of PAX8/PPARG in formalin-fixed, paraffin-embedded thyroid tissue and in fine-needle aspirate biopsy washes from thyroid nodules. The analytical sensitivity of the assay is 1 abnormal cell in a background of 100–10 000 translocation-negative cells. A comparison of the RT-PCR assay with dual-fusion fluorescence in situ hybridization showed an overall concordance of 95%. With this assay, we obtained a prevalence for the PAX8/PPARG rearrangement in FTC of 62% (13 of 21 cases), compared with a 5% prevalence (3 of 55) for other follicular cell–derived neoplasms. Conclusions: The introduction of this assay into clinical practice could provide useful information for the diagnosis and possibly for the prognosis and treatment of thyroid cancer in the future.