Back to Authors

Brinkmann, Benjamin H.

https://orcid.org/0000-0002-2392-8608

Mayo Clinic

Mayo Clinic

Citations 89

Seizure Laterality on EEG is Associated with Thalamic SPECT Lateralization (P4-9.007)
Tanwir, Asra, Mandrekar, Jay , So, Elson, Ortiz‐Guerrero, Gloria , Burkett, Brian J. , So, Elson L., Gompel, Jamie J. Van , Brinkmann, Benjamin H.

Neurology | April 7, 2025 | Volume: 104 | Issue: 7_Supplement_1 | Pages: No page available

10.1212/wnl.0000000000210738 Get It

The FORESITE Study: FOREcasting Seizures to Initiate ThErapy – Technical Design, Hardware, and Algorithms (P5-9.001)
Cui, Jie , Clark, J V, Duun-Henricksen, Jonas, McQuown, Kevin, Sladky, Vladimir , Brinkmann, Benjamin H. , clark, Jordan, Nasseri, Mona , Viana, Pedro F. , Křemen, Václav , Stirling, Rachel E. , Karoly, Philippa J. , Carrazana, Enrique , Schulze‐Bonhage, Andreas , Richardson, Mark, Worrell, Gregory A.

Neurology | April 7, 2025 | Volume: 104 | Issue: 7_Supplement_1 | Pages: No page available

10.1212/wnl.0000000000212204 Get It

Modulating limbic circuits in temporal lobe epilepsy: impacts on seizures, memory, mood and sleep
Křemen, Václav , Sladky, Vladimir , Mívalt, Filip , Gregg, Nicholas M. , Brinkmann, Benjamin H. , Balzekas, Irena , Marks, Victoria S. , Lundstrom, Brian N. , Cui, Jie, Alden, Eva , Fields, Julie A. , Crockett, Karla, Adolf, Jindřich , Bilderbeek, Jordan, Hermes, Dora, Miller, Kai J. , Bilderbeek, Jordan , Marks, Victoria S , Kucewicz, Michal, Lundstrom, Brian Nils , St Louis, E K , Croarkin, Paul E , Alden, Eva C, Messina, Steven, Miller, Kai Joshua, Van Gompel, Jamie, Brinkmann, Benjamin H , Kremen, Vaclav , Gregg, Nicholas M , Bilderbeek, Jordan A , Mivalt, Filip , Kucewicz, Michał T. , Cui, Jie , Louis, Erik K. St. , Croarkin, Paul E. , Joseph, Boney , Hermes, Dora , Messina, Steven A. , Gompel, Jamie J. Van , Denison, Timothy , Worrell, Gregory A.

Brain Communications | March 7, 2025 | Volume: 7 | Issue: 2 | Pages: No page available

10.1093/braincomms/fcaf106 Get It

Abstract Temporal lobe epilepsy is a common neurological disease characterized by recurrent seizures that often originate within limbic networks involving amygdala and hippocampus. The limbic network is involved in crucial physiologic functions involving memory, emotion and sleep. Temporal lobe epilepsy is frequently drug-resistant, and people often experience comorbidities related to memory, mood and sleep. Deep brain stimulation targeting the anterior nucleus of the thalamus (ANT-DBS) is an established therapy for temporal lobe epilepsy. However, the optimal stimulation parameters and their impact on memory, mood and sleep comorbidities remain unclear. We used an investigational brain sensing-stimulation implanted device to accurately track seizures, interictal epileptiform spikes (IES), and memory, mood and sleep comorbidities in five ambulatory subjects. Wireless streaming of limbic network local field potentials (LFPs) and subject behaviour were captured on a mobile device integrated with a cloud environment. Automated algorithms applied to the continuous LFPs were used to accurately cataloged seizures, IES and sleep-wake brain state. Memory and mood assessments were remotely administered to densely sample cognitive and behavioural response during ANT-DBS in ambulatory subjects living in their natural home environment. We evaluated the effect of continuous low-frequency and duty cycle high-frequency ANT-DBS on epileptiform activity and memory, mood and sleep comorbidities. Both low-frequency and high-frequency ANT-DBS paradigms reduced seizures. However, continuous low-frequency ANT-DBS showed greater reductions in IES, electrographic seizures and better sleep and memory outcomes. These results highlight the potential of synchronized brain sensing and dense behavioural tracking during ANT-DBS for optimizing neuromodulation therapy. While studies with larger patient numbers are needed to validate the benefits of low-frequency ANT-DBS, these findings are potentially translatable to individuals currently implanted with ANT-DBS systems.
Seizure Detection and Lateralization Using Thalamic Deep Brain Stimulator Recordings
Ortiz‐Guerrero, Gloria , Park, Sihyeong , Starnes, Keith , Brinkmann, Benjamin H. , Gregg, Nicholas M. , Brinkmann, Benjamin H , Gregg, Nicholas M , Ortiz-Guerrero, Gloria , Starnes, Donnie Keith , Lundstrom, Brian N. , Gompel, Jamie J. Van , Worrell, Gregory A.

Journal of Clinical Neurophysiology | December 18, 2024 | Volume: 42 | Issue: 3 | Pages: 279-283

10.1097/wnp.0000000000001137 Get It

Summary: The lack of reliable seizure detection remains a significant challenge for epilepsy care. A clinical deep brain stimulation (DBS) system provides constrained ambulatory brain recordings; however, limited data exist on the use of DBS recordings for seizure detection and lateralization. We present the case of an 18-year-old patient with drug-resistant focal epilepsy, who had seizure detection and lateralization by DBS recordings. Prior stereotactic-EEG, including a thalamus lead, identified independent left orbitofrontal and mesial temporal onset seizures. Notably, low-frequency thalamic ictal power was significantly elevated relative to baseline awake and sleep states. The patient was subsequently implanted with an anterior nucleus of the thalamus DBS system. Postimplantation, low-frequency power-in-band (5.3–10.3 Hz) recordings were initiated. Nursing staff identified four typical clinical seizures during the inpatient DBS recording period. Thalamic DBS trends contained relative peaks that were coincident with each nurse-reported seizure. Peri-ictal power was uniformly maximal ipsilateral to the seizure network. This case demonstrates the feasibility of seizure detection and lateralization by a thalamic DBS system for some individuals, and suggests DBS sensing parameter selection may be guided by thalamic stereotactic EEG. Further research is necessary to assess the generalizability of DBS seizure detection across individuals and diverse seizure networks.
Automatic Monitoring of High-Frequency Autoimmune Disorder Related Seizures with Wearable Devices
Cui, Jie , Lopez, Andrea Duque, Brinkmann, Gabriella , Faust, Louis , Ethridge, Julianna, Dubey, Divyanshu , Brinkmann, Benjamin H. , Lopez, Andrea Duque , Brinkmann, Benjamin H , Duque Lopez, Andrea M , Joseph, Boney , Worrell, Gregory A. , Dubey, Divyanshu

2024 46th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) | December 17, 2024 | Volume: No volume available | Issue: No issue available | Pages: 1-4

10.1109/embc53108.2024.10782939 Get It

Effects of epileptic seizures on the quality of biosignals recorded from wearables
Böttcher, Sebastian , Zabler, Nicolas , Jackson, Michele , Bruno, Elisa , Biondi, Andrea , Epitashvili, Nino , Vieluf, Solveig , Richardson, Mark P. , Brinkmann, Benjamin H. , Dümpelmann, Matthias , Richardson, Mark P , Brinkmann, Benjamin H , Loddenkemper, Tobias , Schulze-Bonhage, Andreas , Biondi, Andrea , Bruno, Elisa , Vieluf, Solveig , Dümpelmann, Matthias , Loddenkemper, Tobias , Schulze‐Bonhage, Andreas

Epilepsia | October 7, 2024 | Volume: 65 | Issue: 12 | Pages: 3513-3525

10.1111/epi.18138 Get It

Abstract Objective Wearable nonelectroencephalographic biosignal recordings captured from the wrist offer enormous potential for seizure monitoring. However, signal quality remains a challenging factor affecting data reliability. Models trained for seizure detection depend on the quality of recordings in peri‐ictal periods in performing a feature‐based separation of ictal periods from interictal periods. Thus, this study aims to investigate the effect of epileptic seizures on signal quality, ensuring accurate and reliable monitoring. Methods This study assesses the signal quality of wearable data during peri‐ictal phases of generalized tonic–clonic and focal to bilateral tonic–clonic seizures (TCS), focal motor seizures (FMS), and focal nonmotor seizures (FNMS). We evaluated accelerometer (ACC) activity and the signal quality of electrodermal activity (EDA) and blood volume pulse (BVP) data. Additionally, we analyzed the influence of peri‐ictal movements as assessed by ACC (ACC activity) on signal quality and examined intraictal subphases of focal to bilateral TCS. Results We analyzed 386 seizures from 111 individuals in three international epilepsy monitoring units. BVP signal quality and ACC activity levels differed between all seizure types. We found the largest decrease in BVP signal quality and increase in ACC activity when comparing the ictal phase to the pre‐ and postictal phases for TCS. Additionally, ACC activity was strongly negatively correlated with BVP signal quality for TCS and FMS, and weakly for FNMS. Intraictal analysis revealed that tonic and clonic subphases have the lowest BVP signal quality and the highest ACC activity. Significance Motor elements of seizures significantly impair BVP signal quality, but do not have significant effect on EDA signal quality, as assessed by wrist‐worn wearables. The results underscore the importance of signal quality assessment methods and careful selection of robust modalities to ensure reliable seizure detection. Future research is needed to explain whether seizure detection models' decisions are based on signal responses induced by physiological processes as opposed to artifacts.
Data-driven retrieval of population-level EEG features and their role in neurodegenerative diseases
Li, Wentao , Varatharajah, Yogatheesan , Dicks, Ellen , Barnard, Leland R , Brinkmann, Benjamin H. , Crepeau, Daniel, Fan, Winnie, Kremers, Walter K. , Boeve, Bradley F. , Gogineni, Venkatsampath, Boeve, Brad , Botha, Hugo , Jones, David T , Brinkmann, Benjamin H , Kremers, Walter K , Worrell, Gregory A. , Fan, Winnie, Botha, Hugo , Jones, David T.

Brain Communications | August 1, 2024 | Volume: 6 | Issue: 4 | Pages: No page available

10.1093/braincomms/fcae227 Get It

Abstract Electrophysiologic disturbances due to neurodegenerative disorders such as Alzheimer’s disease and Lewy Body disease are detectable by scalp EEG and can serve as a functional measure of disease severity. Traditional quantitative methods of EEG analysis often require an a-priori selection of clinically meaningful EEG features and are susceptible to bias, limiting the clinical utility of routine EEGs in the diagnosis and management of neurodegenerative disorders. We present a data-driven tensor decomposition approach to extract the top 6 spectral and spatial features representing commonly known sources of EEG activity during eyes-closed wakefulness. As part of their neurologic evaluation at Mayo Clinic, 11 001 patients underwent 12 176 routine, standard 10–20 scalp EEG studies. From these raw EEGs, we developed an algorithm based on posterior alpha activity and eye movement to automatically select awake-eyes-closed epochs and estimated average spectral power density (SPD) between 1 and 45 Hz for each channel. We then created a three-dimensional (3D) tensor (record × channel × frequency) and applied a canonical polyadic decomposition to extract the top six factors. We further identified an independent cohort of patients meeting consensus criteria for mild cognitive impairment (30) or dementia (39) due to Alzheimer’s disease and dementia with Lewy Bodies (31) and similarly aged cognitively normal controls (36). We evaluated the ability of the six factors in differentiating these subgroups using a Naïve Bayes classification approach and assessed for linear associations between factor loadings and Kokmen short test of mental status scores, fluorodeoxyglucose (FDG) PET uptake ratios and CSF Alzheimer’s Disease biomarker measures. Factors represented biologically meaningful brain activities including posterior alpha rhythm, anterior delta/theta rhythms and centroparietal beta, which correlated with patient age and EEG dysrhythmia grade. These factors were also able to distinguish patients from controls with a moderate to high degree of accuracy (Area Under the Curve (AUC) 0.59–0.91) and Alzheimer’s disease dementia from dementia with Lewy Bodies (AUC 0.61). Furthermore, relevant EEG features correlated with cognitive test performance, PET metabolism and CSF AB42 measures in the Alzheimer’s subgroup. This study demonstrates that data-driven approaches can extract biologically meaningful features from population-level clinical EEGs without artefact rejection or a-priori selection of channels or frequency bands. With continued development, such data-driven methods may improve the clinical utility of EEG in memory care by assisting in early identification of mild cognitive impairment and differentiating between different neurodegenerative causes of cognitive impairment.
How accurate do self‐reported seizures need to be for effective medication management in epilepsy?
Goldenholz, Daniel M. , Brinkmann, Benjamin H. , Goldenholz, Daniel M , Brinkmann, Benjamin H , Westover, M. Brandon

Epilepsia | May 22, 2024 | Volume: 65 | Issue: 7 | Pages: No page available

10.1111/epi.18019 Get It

AbstractStudies suggest that self‐reported seizure diaries suffer from 50% under‐reporting on average. It is unknown to what extent this impacts medication management. This study used simulation to predict the seizure outcomes of a large heterogeneous clinic population treated with a standardized algorithm based on self‐reported seizures. Using CHOCOLATES, a state‐of‐the‐art realistic seizure diary simulator, 100 000 patients were simulated over 10 years. A standard algorithm for medication management was employed at 3 month intervals for all patients. The impact on true seizure rates, expected seizure rates, and time‐to‐steady‐dose were computed for self‐reporting sensitivities 0%–100%. Time‐to‐steady‐dose and medication use mostly did not depend on sensitivity. True seizure rate decreased minimally with increasing self‐reporting in a non‐linear fashion, with the largest decreases at low sensitivity rates (0%–10%). This study suggests that an extremely wide range of sensitivity will have similar seizure outcomes when patients are clinically treated using an algorithm similar to the one presented. Conversely, patients with sensitivity ≤10% would be expected to benefit (via lower seizure rates) from objective devices that provide even small improvements in seizure sensitivity.
Minimum clinical utility standards for wearable seizure detectors: A simulation study
Goldenholz, Daniel M. , Karoly, Philippa J. , Viana, Pedro F. , Nurse, Ewan S. , Bruno, Elisa , Richardson, Mark P. , Brinkmann, Benjamin H. , Westover, M. Brandon , Nurse, Ewan , Schulze-Bonhage, Andreas , Bruno, Elisa , Nasseri, Mona , Richardson, Mark P , Brinkmann, Benjamin H , Karoly, Phillipa J , Goldenholz, Daniel M , Viana, Pedro F , Westover, M Brandon , Loddenkemper, Tobias , Schulze‐Bonhage, Andreas , Vieluf, Solveig

Epilepsia | February 17, 2024 | Volume: 65 | Issue: 4 | Pages: 1017-1028

10.1111/epi.17917 Get It

AbstractObjectiveEpilepsy management employs self‐reported seizure diaries, despite evidence of seizure underreporting. Wearable and implantable seizure detection devices are now becoming more widely available. There are no clear guidelines about what levels of accuracy are sufficient. This study aimed to simulate clinical use cases and identify the necessary level of accuracy for each.MethodsUsing a realistic seizure simulator (CHOCOLATES), a ground truth was produced, which was then sampled to generate signals from simulated seizure detectors of various capabilities. Five use cases were evaluated: (1) randomized clinical trials (RCTs), (2) medication adjustment in clinic, (3) injury prevention, (4) sudden unexpected death in epilepsy (SUDEP) prevention, and (5) treatment of seizure clusters. We considered sensitivity (0%–100%), false alarm rate (FAR; 0–2/day), and device type (external wearable vs. implant) in each scenario.ResultsThe RCT case was efficient for a wide range of wearable parameters, though implantable devices were preferred. Lower accuracy wearables resulted in subtle changes in the distribution of patients enrolled in RCTs, and therefore higher sensitivity and lower FAR values were preferred. In the clinic case, a wide range of sensitivity, FAR, and device type yielded similar results. For injury prevention, SUDEP prevention, and seizure cluster treatment, each scenario required high sensitivity and yet was minimally influenced by FAR.SignificanceThe choice of use case is paramount in determining acceptable accuracy levels for a wearable seizure detection device. We offer simulation results for determining and verifying utility for specific use case and specific wearable parameters.
Spike ripples localize the epileptogenic zone best: an international intracranial study
Shi, Wen , Shaw, Dana , Walsh, Katherine G. , Han, Xue , Eden, Uri T. , Gliske, S. , Jacobs, Julia , Brinkmann, Benjamin H. , Worrell, Gregory A. , Kramer, Mark , Chu, Catherine J. , Gliske, Stephen V , Brinkmann, Benjamin H , Worrell, Gregory A , Kramer, Mark A , Chu, Catherine J , Richardson, Robert Mark , Stacey, William C. , Frauscher, Birgit , Thomas, John Paul

Brain | February 7, 2024 | Volume: 147 | Issue: 7 | Pages: 2496-2506

10.1093/brain/awae037 Get It

Abstract We evaluated whether spike ripples, the combination of epileptiform spikes and ripples, provide a reliable and improved biomarker for the epileptogenic zone compared with other leading interictal biomarkers in a multicentre, international study. We first validated an automated spike ripple detector on intracranial EEG recordings. We then applied this detector to subjects from four centres who subsequently underwent surgical resection with known 1-year outcomes. We evaluated the spike ripple rate in subjects cured after resection [International League Against Epilepsy Class 1 outcome (ILAE 1)] and those with persistent seizures (ILAE 2–6) across sites and recording types. We also evaluated available interictal biomarkers: spike, spike-gamma, wideband high frequency oscillation (HFO, 80–500 Hz), ripple (80–250 Hz) and fast ripple (250–500 Hz) rates using previously validated automated detectors. The proportion of resected events was computed and compared across subject outcomes and biomarkers. Overall, 109 subjects were included. Most spike ripples were removed in subjects with ILAE 1 outcome (P < 0.001), and this was qualitatively observed across all sites and for depth and subdural electrodes (P < 0.001 and P < 0.001, respectively). Among ILAE 1 subjects, the mean spike ripple rate was higher in the resected volume (0.66/min) than in the non-removed tissue (0.08/min, P < 0.001). A higher proportion of spike ripples were removed in subjects with ILAE 1 outcomes compared with ILAE 2–6 outcomes (P = 0.06). Among ILAE 1 subjects, the proportion of spike ripples removed was higher than the proportion of spikes (P < 0.001), spike-gamma (P < 0.001), wideband HFOs (P < 0.001), ripples (P = 0.009) and fast ripples (P = 0.009) removed. At the individual level, more subjects with ILAE 1 outcomes had the majority of spike ripples removed (79%, 38/48) than spikes (69%, P = 0.12), spike-gamma (69%, P = 0.12), wideband HFOs (63%, P = 0.03), ripples (45%, P = 0.01) or fast ripples (36%, P < 0.001) removed. Thus, in this large, multicentre cohort, when surgical resection was successful, the majority of spike ripples were removed. Furthermore, automatically detected spike ripples localize the epileptogenic tissue better than spikes, spike-gamma, wideband HFOs, ripples and fast ripples.