Abstract Translational large-animal models that can accommodate human-scale implantable devices are essential for advancing neuromodulation therapies in epilepsy. This study establishes a kainic acid (KA)-induced porcine model of mesial temporal lobe epilepsy (mTLE) using clinical imaging, stereotactic surgery, and a fully implantable neural stimulation and recording (INSR) device designed for humans. Seven pigs (six KA-treated and one saline control) underwent MRI-guided stereotactic implantation of electrodes targeting bilateral hippocampus (HPC) and anterior thalamus (ANT), followed by intra-hippocampal KA or saline infusion. Local field potentials (LFP) were recorded continuously with synchronized video monitoring. Seizures and LFP interictal epileptiform-like discharges (IEDs) were quantified using validated automated detectors. Histology was performed in the saline control and the longest surviving KA-treated pig. Intra-hippocampal KA infusion induced acute status epilepticus in all (6/6) treated pigs. Four animals survived to chronic monitoring with spontaneous seizures observed in three pigs (2,733 seizures; mean duration of 27.2 ± 17.6 seconds). IEDs were observed in bilateral HPC of all animals, including saline control, with higher rates in the lesioned HPC (p <0.0001). While the IED morphology is consistent with epileptiform activity; IEDs alone are not specific for epilepsy and physiological transients (e.g. sharp-wave ripples) and injury-related hyperexcitability or strain-specific hyperexcitability cannot be excluded. Histological analysis revealed patchy neuronal loss and cytoarchitectural changes in HPC. This porcine model reproduces electrophysiological features of human mTLE. This approach provides a powerful translational bridge for developing and testing next-generation INSR and neuromodulation strategies in freely behaving large animals.
Automatic Monitoring of High-Frequency Autoimmune Disorder Related Seizures with Wearable Devices
2024 46th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) | December 17, 2024 | Volume: No volume available | Issue: No issue available | Pages: 1-4
Abstract Objective An accurate evaluation of behavioral responsiveness during and after seizures in people with epilepsy is critical for diagnosis and management. Current methods for assessing behavioral responsiveness are characterized by substantial variation, subjectivity, and limited reliability and reproducibility in ambulatory and epilepsy monitoring unit settings. In this study, we aimed to develop and implement a novel mobile platform for deployment of automated responsiveness testing in epilepsy—the ARTiE Watch—to facilitate standardized, objective assessments of behavioral responsiveness during and after seizures. Methods We prospectively recruited patients admitted to the epilepsy monitoring units for diagnostic evaluation and long‐term video‐electroencephalographic monitoring at Mayo Clinic and Yale New Haven Hospital. Participants wore the ARTiE Watch, a smartwatch paired with custom smartphone software integrated with cloud infrastructure allowing for remote activation of standardized assessment on the participants' smartwatches. The assessment consisted of 18 command prompts that test behavioral responsiveness across motor, language, and memory domains. Upon visually identifying an electrographic seizure during EMU monitoring, the BrainRISE platform was used to deploy the ARTiE Watch behavioral testing sequence. Responsiveness scoring was conducted on smartwatch files. Results Eighteen of 56 participants had a total of 39 electrographic seizures assessed with the ARTiE Watch. The 18 subjects with ARTiE Watch‐tested seizures had a total of 67 baseline (interictal) ARTiE Watch tests collected for analysis. The analysis showed distinct ARTiE Watch behavioral responsiveness phenotypes: (1) decreased responsiveness across all ARTiE Watch commands during seizure (ictal–postictal) periods compared (to baseline ( p < .0001), (2) decreased responsiveness in bilateral tonic–clonic seizures compared to baseline ( p < .0001) and compared to focal seizures ( p < .0001), and (3) decreased responsiveness during focal impaired awareness seizures compared to baseline ( p < .0001) and compared to focal aware seizures ( p < .001). Significance ARTiE Watch behavioral testing deployed utilizing a mobile cloud‐based platform is feasible and can provide standardized, objective behavioral responsiveness assessments during seizures.
Electroencephalographic source imaging of spikes with concurrent high‐frequency oscillations is concordant with the clinical ground truth
AbstractObjectiveEpilepsy raises critical challenges to accurately localize the epileptogenic zone (EZ) to guide presurgical planning. Previous research has suggested that interictal spikes overlapping with high‐frequency oscillations, referred to here as pSpikes, serve as a reliable biomarker for EZ estimation, but there remains a question as to whether and to how pSpikes perform as compared to other types of epileptic spikes. This study aims to address this question by investigating the source imaging capabilities of pSpikes alongside other spike types.MethodsA total of 2819 interictal spikes from 76‐channel scalp electroencephalography (EEG) were analyzed in a cohort of 24 drug‐resistant focal epilepsy patients. All patients received surgical resection, and 16 were declared seizure‐free based on at least 1 year of postoperative follow‐up. A recently developed electrophysiological source imaging algorithm—fast spatiotemporal iteratively reweighted edge sparsity (FAST‐IRES)—was used for source imaging of the detected interictal spikes. The performance of 217 pSpikes was compared with 772 nSpikes (spikes with irregular high‐frequency activations), 1830 rSpikes (spikes with no high‐frequency activity), and all 2819 aSpikes (all interictal spikes).ResultsThe localization and extent estimation using pSpikes are concordant with the clinical ground truth; using pSpikes yields the best performance compared with nSpikes, rSpikes, and conventional spike imaging (aSpikes). For multiple spike type seizure‐free patients, the mean localization error for pSpike imaging was 6.8 mm, compared with 15.0 mm for aSpikes. The sensitivity, precision, and specificity were .41, .67, and .93 for pSpikes compared with .32, .48, and .93 for aSpikes.SignificanceThese results demonstrate the merits of noninvasive EEG source localization, and that (1) pSpike is a superior biomarker, outperforming conventional spike imaging for the localization of epileptic sources, and especially those with multiple irritative zones; and (2) FAST‐IRES provides accurate source estimation that is highly concordant with clinical ground truth, even in situations of single spike analysis with low signal‐to‐noise ratio.