Back to Authors

Pavlicek, William

https://orcid.org/0000-0002-2499-2011

Mayo Clinic

Mayo Clinic

Citations 15

Digital Mammography, Tomosynthesis, and Contrast-Enhanced Mammography: Intraindividual Comparison of Mean Glandular Dose for Screening Examinations
Sanders, Jeremiah , Pavlicek, William , Stefan, Wolfgang, Sanders, Jeremiah W , Hanson, James, Sharpe, Richard E. , Hanson, James , Patel, Bhavika

American Journal of Roentgenology | January 15, 2025 | Volume: 224 | Issue: 3 | Pages: No page available

10.2214/ajr.24.32150 Get It

Estimation of patient skin dose in fluoroscopy: summary of a joint report by AAPM TG357 and EFOMP
Andersson, Jonas , Bednarek, Daniel R. , Boltz, Thomas, Bosmans, Hilde , Gislason‐Lee, Amber J., Granberg, Christoffer, Hellström, Max , Kanal, Kalpana M. , McDonagh, Ed, Paden, Robert G., Pavlicek, William , Khodadadegan, Yasaman, Torresin, A. , Trianni, Annalisa , Zamora, D , Paden, Robert, Bolch, Wesley E.

Medical Physics | April 30, 2021 | Volume: 48 | Issue: 7 | Pages: No page available

10.1002/mp.14910 Get It

BackgroundPhysicians use fixed C‐arm fluoroscopy equipment with many interventional radiological and cardiological procedures. The associated effective dose to a patient is generally considered low risk, as the benefit‐risk ratio is almost certainly highly favorable. However, X‐ray‐induced skin injuries may occur due to high absorbed patient skin doses from complex fluoroscopically guided interventions (FGI). Suitable action levels for patient‐specific follow‐up could improve the clinical practice.There is a need for a refined metric regarding follow‐up of X‐ray‐induced patient injuries and the knowledge gap regarding skin dose‐related patient information from fluoroscopy devices must be filled. The most useful metric to indicate a risk of erythema, epilation or greater skin injury that also includes actionable information is the peak skin dose, that is, the largest dose to a region of skin.Materials and MethodsThe report is based on a comprehensive review of best practices and methods to estimate peak skin dose found in the scientific literature and situates the importance of the Digital Imaging and Communication in Medicine (DICOM) standard detailing pertinent information contained in the Radiation Dose Structured Report (RDSR) and DICOM image headers for FGI devices. Furthermore, the expertise of the task group members and consultants have been used to bridge and discuss different methods and associated available DICOM information for peak skin dose estimation.ResultsThe report contributes an extensive summary and discussion of the current state of the art in estimating peak skin dose with FGI procedures with regard to methodology and DICOM information. Improvements in skin dose estimation efforts with more refined DICOM information are suggested and discussed.ConclusionsThe endeavor of skin dose estimation is greatly aided by the continuing efforts of the scientific medical physics community, the numerous technology enhancements, the dose‐controlling features provided by the FGI device manufacturers, and the emergence and greater availability of the DICOM RDSR. Refined and new dosimetry systems continue to evolve and form the infrastructure for further improvements in accuracy. Dose‐related content and information systems capable of handling big data are emerging for patient dose monitoring and quality assurance tools for large‐scale multihospital enterprises.
Sample content of kinesthetic educational training: Reducing scattered X‐ray exposures to interventional physician operators of fluoroscopy
Pavlicek, William , Paden, Robert G., Panda, Anshuman , Hines, Justin K. , Naidu, Sailendra , Öklü, Rahmi , Sensakovic, William F. , Hines, Justin, Naidu, Sailendra G, Oklu, Rahmi , Zhou, Yuxiang , Hines, Justin

Journal of Applied Clinical Medical Physics | December 30, 2019 | Volume: 21 | Issue: 7 | Pages: 196-208

10.1002/acm2.12801 Get It

AbstractContent used by Medical Physicists for fluoroscopy safety training to staff is deliverable via several formats, that is, online content or a live audience slide presentations. Here, we share one example of a kinesthetic (live, hands‐on simulation) educational program in use at our facility for some time (~10 years). In this example, the format and content specifically target methods of reducing physician operator exposures from scattered x rays. A kinesthetic format identifies and promotes the adoption of exposure‐reducing behaviors. Key kinesthetic elements of this type of training include: physician hands‐on measurements of radiation levels at locations specific to their standing positions (e.g., primary arterial access points) in the room using handheld exposure rate meters, measurement of exposure rate reduction to physicians provided by using personal protective equipment, that is, wearable aprons, hanging lead drapes, and pull‐down shields. Physician choice of procedure‐specific tableside selectable controls affecting exposure rate from optional fluoroscopy, Cine or digital subtraction angiography (DSA), along with comparative measured contribution to physician exposure is demonstrated. The inverse square exposure rate reduction to physicians when stepping back from the table during DSA is a key observation. Kinesthetic simulations in the rooms used by physicians have been found to provide the highest level of understanding giving rise to adoption of practices that are impactful for physicians. Specific training scripts are in place for physician sub‐specialization in interventional radiology, cardiology, neurosurgery, vascular surgery, and gastroenterology. This training is used for new physician staff while classroom presentations (whose content mimics in room training) are used with staff who have had previously had in room training.
Redefining and reinvigorating the role of physics in clinical medicine: A Report from the AAPM Medical Physics 3.0 Ad Hoc Committee
Samei, Ehsan , Pawlicki, Todd , Bourland, Daniel, Chin, Erika, Das, Shiva K., Fox, Mary Kay , Freedman, D. Jay, Hangiandreou, Nicholas J., Jordan, David W. , Martin, Melissa , Pavlicek, William , Pavord, Daniel, Schober, Lisa, Thomadsen, Bruce , Whelan, Brendan , Hangiandreou, Nicholas, Fox, Mary, Miller, Robin June

Medical Physics | July 10, 2018 | Volume: 45 | Issue: 9 | Pages: No page available

10.1002/mp.13087 Get It

Derived from 2 yr of deliberations and community engagement, Medical Physics 3.0 ( MP 3.0) is an effort commissioned by the American Association of Physicists in Medicine ( AAPM ) to devise a framework of strategies by which medical physicists can maintain and improve their integral roles in, and contributions to, health care and its innovation under conditions of rapid change and uncertainty. Toward that goal, MP 3.0 advocates a broadened and refreshed model of sustainable excellence by which medical physicists can and should contribute to health care. The overarching conviction of MP 3.0 is that every healthcare facility can benefit from medical physics and every patient's care can be improved by a medical physicist. This large and expansive challenge necessitates a range of strategies specific to each area of medical physics: clinical practice, research, product development, and education. The present paper offers a summary of the Phase 1 deliberations of the MP 3.0 initiative pertaining to strategic directions of the discipline primarily but not exclusively oriented toward the clinical practice of medical physics in the United States.
MR efficiency using automated MRI-desktop eProtocol
Gao, Fei , Xu, Yanzhe , Panda, Anshuman , Zhang, Min , Su, Congzhe , Pavlicek, William , James, J.R. , Hanson, James, Wu, Teresa , James, Judy R.

SPIE Proceedings | March 13, 2017 | Volume: 10138 | Issue: No issue available | Pages: 101380Z

10.1117/12.2249712 Get It

Coronary calcium quantification using contrast‐enhanced dual‐energy computed tomography scans
Yamak, Didem, Pavlicek, William , Boltz, Thomas, Panse, Prasad M., Akay, Metin

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 14 | Issue: 3 | Pages: 203-214

10.1120/jacmp.v14i3.4014 Get It

The purpose of this study is to evaluate a direct measure of calcium burden by using dual‐energy computed tomography (DECT) during contrast‐enhanced coronary imaging, potentially eliminating the need for an extra noncontrast X‐ray acquisition. The ambiguity of separation of calcium from contrast material on contrast‐enhanced images was solved by using virtual noncontrast images obtained by DECT. A new threshold CT number was required to detect the calcium carrying potential risk for adverse coronary events on virtual noncontrast images. Two methods were investigated to determine the 130 HU threshold for DECT scoring. An in vitro anthropomorphic phantom with 29 excised patient calcium plaques inserted was used for both a linear and a logistic regression analysis. An IRB approved in vivo prospective study of six patients was also performed to be used for logistic regression analysis. The threshold found by logistic regression model to define the calcium burden on virtual noncontrast images detects the calcium carrying potential risk for adverse coronary events correctly (2.45% error rate). DECT calcium mass and volume scores obtained by using the threshold correlates with both conventional Agatston and volume scores . A conventional CT cardiac exam requires two scans, including a noncontrast scan for calcium quantification and a contrast‐enhanced scan for coronary angiography. With the ability to quantify calcium on DECT contrast‐enhanced images, a DECT cardiac exam could be accomplished with one contrast‐enhanced scan for both calcium quantification and coronary angiography.PACS numbers: 87.57.Q, 87.57.N
An anthropomorphic beating heart phantom for cardiac X‐ray CT imaging evaluation
Boltz, Thomas, Pavlicek, William , Paden, Robert G., Renno, Markus S. , Jensen, Angela , Akay, Metin

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 11 | Issue: 1 | Pages: 191-199

10.1120/jacmp.v11i1.3129 Get It

The current work describes an anthropomorphic beating heart phantom constructed as a tool for the assessment of technological advances in cardiac X‐ray computed tomography (CT). The phantom is comprised of a thorax, a compressor system, an ECG system, a beating heart with tortuous coronary arteries, and the option to add or remove pathologies such as aberrant beats, stents, and plaques. Initial trials with the phantom have shown its utility to assess temporal resolution, spatial resolution, radiation dose, iodine contrast, stents, and plaques.PACS numbers: 87.59.Fm, 87.57.Ce
Breast Radiation Dose With CESM Compared With 2D FFDM and 3D Tomosynthesis Mammography
James, J.R. , Pavlicek, William , Hanson, James A., Boltz, Thomas, Patel, Bhavika , James, Judy R, Boltz, Thomas F, James, Judy R., Hanson, James A., Patel, Bhavika K

American Journal of Roentgenology | January 23, 2017 | Volume: 208 | Issue: 2 | Pages: 362-372

10.2214/ajr.16.16743 Get It