Back to Authors

Sanders, Jeremiah

https://orcid.org/0000-0002-5342-4128

Mayo Clinic

Mayo Clinic

Citations 3

Breast MRI in Patients With Active Implanted Metallic Devices: How We Do It
Sanders, Jeremiah , Panda, Anshuman , Harper, Laura, Patel, Bhavika , Sharpe, Richard, Sanders, Jeremiah W , Sharpe, Richard E.

American Journal of Roentgenology | March 25, 2026 | Volume: 227 | Issue: 1 | Pages: No page available

10.2214/ajr.26.34661 Get It

Digital Mammography, Tomosynthesis, and Contrast-Enhanced Mammography: Intraindividual Comparison of Mean Glandular Dose for Screening Examinations
Sanders, Jeremiah , Pavlicek, William , Stefan, Wolfgang, Sanders, Jeremiah W , Hanson, James, Sharpe, Richard E. , Hanson, James , Patel, Bhavika

American Journal of Roentgenology | January 15, 2025 | Volume: 224 | Issue: 3 | Pages: No page available

10.2214/ajr.24.32150 Get It

A Novel Positive-Contrast Magnetic Resonance Imaging Line Marker for High-Dose-Rate (HDR) MRI-Assisted Radiosurgery (MARS)
Bruno, Teresa L., Sanders, Jeremiah , Ning, Matthew S. , Ma, Jingfei , Klopp, Ann H. , Venkatesan, Aradhana M. , Martirosyan, Karen S. , Sanders, Jeremiah W , Ning, Matthew S , Ma, Jingfei , Klopp, Ann H , Martirosyan, Karen S , Venkatesan, Aradhana M , Wang, Li , Ding, Yao , Stafford, R. Jason , Lin, Eric, Bathala, Tharakeswara K , Wang, Jihong , Frank, Steven J.

Cancers | May 20, 2024 | Volume: 16 | Issue: 10 | Pages: 1922

10.3390/cancers16101922 Get It

Magnetic resonance imaging (MRI) can facilitate accurate organ delineation and optimal dose distributions in high-dose-rate (HDR) MRI-Assisted Radiosurgery (MARS). Its use for this purpose has been limited by the lack of positive-contrast MRI markers that can clearly delineate the lumen of the HDR applicator and precisely show the path of the HDR source on T1- and T2-weighted MRI sequences. We investigated a novel MRI positive-contrast HDR brachytherapy or interventional radiotherapy line marker, C4:S, consisting of C4 (visible on T1-weighted images) complexed with saline. Longitudinal relaxation time (T1) and transverse relaxation time (T2) for C4:S were measured on a 1.5 T MRI scanner. High-density polyethylene (HDPE) tubing filled with C4:S as an HDR brachytherapy line marker was tested for visibility on T1- and T2-weighted MRI sequences in a tissue-equivalent female ultrasound training pelvis phantom. Relaxivity measurements indicated that C4:S solution had good T1-weighted contrast (relative to oil [fat] signal intensity) and good T2-weighted contrast (relative to water signal intensity) at both room temperature (relaxivity ratio > 1; r2/r1 = 1.43) and body temperature (relaxivity ratio > 1; r2/r1 = 1.38). These measurements were verified by the positive visualization of the C4:S (C4/saline 50:50) HDPE tube HDR brachytherapy line marker on both T1- and T2-weighted MRI sequences. Orientation did not affect the relaxivity of the C4:S contrast solution. C4:S encapsulated in HDPE tubing can be visualized as a positive line marker on both T1- and T2-weighted MRI sequences. MRI-guided HDR planning may be possible with these novel line markers for HDR MARS for several types of cancer.