Back to Authors

Crockford, Erika

Mayo Clinic

Mayo Clinic

Citations 4

Diagnosis of acute myocardial infarction in patients with renal failure using high-sensitivity cardiac troponin T
Ola, Oluwabukola Mary , Akula, Ashok , Slusser, Josh, Mehta, Ramila A. , Crockford, Erika, Lobo, R , Hodge, Dave, Grube, Eric , Tak, Tahir , Cagin, C, Gulati, R, Sandoval, Yader , Jaffe, Allan S. , Knott, J, Ola, O, Michieli, Laura De , Grube, E, Jaffe, Allan S.

European Heart Journal | October 28, 2024 | Volume: 45 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehae666.1590 Get It

Abstract Background Diagnosing myocardial infarction (MI) in patients with chronic kidney disease (CKD) is difficult as these patients often have elevated baseline high-sensitivity cardiac troponin T (hs-cTnT) concentrations. Methods Observational U.S. cohort study of emergency department (ED) patients undergoing hs-cTnT measurement. Cases with >1 hs-cTnT increase >99th percentile were adjudicated following the Fourth Universal Definition of MI. Diagnostic performance of baseline and serial 2- and 6-hour hs-cTnT thresholds for ruling-in acute MI was compared between those without and with CKD (eGFR <60 ml/min/1.73m2). Results The study cohort included 1992 patients, amongst whom 501 (25%) had CKD. There were 701 (82%) patients with myocardial injury, 64 (7.5%) with type 1, and 91 (11%) with type 2 MI. In CKD patients with baseline hs-cTnT thresholds of >52, >100, >200 or >300 ng/L, PPVs for acute MI were 37% [95% CI 28-46], 53% (95% CI 39-67), 73% (95% CI 50-89) and 80% (95% CI 44-98), and in those without CKD, 64% (95% CI 50-77), 69% (95% CI 49-85), 59% (95% CI 33-82) and 54% (95% CI 25-81). In CKD patients with a 2-hour hs-cTnT delta of >10, >20 or >30 ng/L, the corresponding PPVs were 65% (95% CI 50-78), 86% (95% CI 68-96) and 88% (95% CI 68-97), and in those without CKD, 65% (95% CI 51-78), 73% (95% CI 57-86) and 75% (95% CI 58-88) (Figure). Conclusion Diagnostic performance of standard baseline and serial 2-hour hs-cTnT thresholds to rule-in MI is suboptimal in patients with CKD. It significantly improves when using higher baseline thresholds and delta values.
Diagnosis of acute myocardial infarction in patients with renal failure using high-sensitivity cardiac troponin T
Knott, Jonathan D , Ola, Olatunde , Michieli, Laura De , Akula, Ashok , Mehta, Ramila A. , Dworak, Marshall , Crockford, Erika, Lobo, Ronstan , Slusser, Joshua P. , Rastas, Nicholas, Karturi, Swetha, Wohlrab, Scott, Hodge, David O. , Grube, Eric , Tak, Tahir , Cagin, Charles , Gulati, Rajiv , Sandoval, Yader , Jaffe, Allan S. , De Michieli, Laura , Slusser, Joshua, Knott, Jonathan , Grube, Eric, Jaffe, Allan S.

European Heart Journal: Acute Cardiovascular Care | June 30, 2024 | Volume: 13 | Issue: 7 | Pages: 546-558

10.1093/ehjacc/zuae079 Get It

Abstract Aims Diagnosing myocardial infarction (MI) in patients with chronic kidney disease (CKD) is difficult as they often have increased high-sensitivity cardiac troponin T (hs-cTnT) concentrations. Methods and results Observational US cohort study of emergency department patients undergoing hs-cTnT measurement. Cases with ≥1 hs-cTnT increase > 99th percentile were adjudicated following the Fourth Universal Definition of MI. Diagnostic performance of baseline and serial 2 h hs-cTnT thresholds for ruling-in acute MI was compared between those without and with CKD (estimated glomerular filtration rate < 60 mL/min/1.73 m2). The study cohort included 1992 patients, amongst whom 501 (25%) had CKD. There were 75 (15%) and 350 (70%) patients with CKD and 80 (5%) and 351 (24%) without CKD who had acute MI and myocardial injury. In CKD patients with baseline hs-cTnT thresholds of ≥52, >100, >200, or >300 ng/L, positive predictive values (PPVs) for MI were 36% (95% CI 28–45), 53% (95% CI 39–67), 73% (95% CI 50–89), and 80% (95% CI 44–98), and in those without CKD, 61% (95% CI 47–73), 69% (95% CI 49–85), 59% (95% CI 33–82), and 54% (95% CI 25–81). In CKD patients with a 2 h hs-cTnT delta of ≥10, >20, or >30 ng/L, PPVs were 66% (95% CI 51–79), 86% (95% CI 68–96), and 88% (95% CI 68–97), and in those without CKD, 64% (95% CI 50–76), 73% (95% CI 57–86), and 75% (95% CI 58–88). Conclusion Diagnostic performance of standard baseline and serial 2 h hs-cTnT thresholds to rule-in MI is suboptimal in CKD patients. It significantly improves when using higher baseline thresholds and delta values.
Major adverse cardiovascular events after diagnosis of myocardial injury and types 1 and 2 myocardial infarction
Knott, Jonathan D , Ola, Olatunde , Akula, Ashok , Mehta, Ramila A. , Dworak, Marshall , Crockford, Erika, Lobo, Ronstan , Rastas, Nicholas, Karturi, Swetha, Wohlrab, Scott, Hodge, David O. , Grube, Eric , Tak, Tahir , Cagin, Charles , Gulati, Rajiv , Jaffe, Allan S. , Sandoval, Yader , Sandoval, Yader , Michieli, Laura De , Grube, Eric, Jaffe, Allan S.

European Heart Journal. Acute Cardiovascular Care | June 18, 2022 | Volume: 11 | Issue: 7 | Pages: 546-557

10.1093/ehjacc/zuac075 Get It

Abstract Aims Limited US outcome data exist among patients with myocardial injury and types 1 and 2 myocardial infarction (MI) evaluated with high-sensitivity cardiac troponin (hs-cTn). Methods and results This is an observational US cohort study of emergency department (ED) patients undergoing hs-cTnT measurement. Cases with ≥1 hs-cTnT increase >99th percentile were adjudicated following the Fourth Universal Definition of MI. Post-discharge major adverse cardiovascular events (MACE) included death, MI, heart failure (HF) hospitalization, stroke or transient ischaemic attack, and new-onset atrial fibrillation or flutter during 2 years follow-up. Among 2002 patients, 857 (43%) had ≥1 hs-cTnT >99th percentile. Among these, 702 (81.9%) had myocardial injury, 64 (7.5%) had type 1 MI, and 91 (10.6%) had type 2 MI. Compared with patients without myocardial injury, type 2 MI [8.4 vs. 50%; adjusted hazard ratio (HR) 2.31, 95% confidence interval (CI) 1.49–3.58] and myocardial injury (8.4 vs. 47%; adjusted HR 3.13, 95% CI 2.39–4.09) had a higher risk of MACE, in large part because of death and HF hospitalizations. Compared with patients with type 1 MI, type 2 MI (23 vs. 50%; adjusted HR 2.24; 95% CI 1.23–4.10) and myocardial injury (23 vs. 47%; adjusted HR 2.02; 95% CI 1.20–3.40) also have a higher risk of MACE. Conclusion Among unselected US ED patients undergoing hs-cTnT measurement, most increases are due to myocardial injury, and type 2 MI is more frequent than type 1 MI. Patients with myocardial injury and type 2 MI have morbid outcomes, in large part due to death and HF.
Rapid Exclusion of Acute Myocardial Injury and Infarction With a Single High-Sensitivity Cardiac Troponin T in the Emergency Department: A Multicenter United States Evaluation
Sandoval, Yader , Lewis, Bradley R., Mehta, Ramila A. , Ola, Olatunde , Knott, Jonathan D , Michieli, Laura De , Akula, Ashok , Lobo, Ronstan , Gharacholou, S. Michael , Dworak, Marshall , Crockford, Erika, Rastas, Nicholas, Grube, Eric , Karturi, Swetha, Wohlrab, Scott, Hodge, David O. , Tak, Tahir , Cagin, Charles , Gulati, Rajiv , Jaffe, Allan S. , Lewis, Bradley R , De Michieli, Laura , Dworak, Marshall , Gulati, Rajiv , Jaffe, Allan S. , Yang, Eric H. , Grube, Eric

Circulation | May 10, 2022 | Volume: 145 | Issue: 23 | Pages: 1708-1719

10.1161/circulationaha.122.059235 Get It

Background: There are good data to support using a single high-sensitivity cardiac troponin T (hs-cTnT) below the limit of detection of 5 ng/L to exclude acute myocardial infarction. Per the US Food and Drug Administration, hs-cTnT can only report to the limit of quantitation of 6 ng/L, a threshold for which there are limited data. Our goal was to determine whether a single hs-cTnT below the limit of quantitation of 6 ng/L is a safe strategy to identify patients at low risk for acute myocardial injury and infarction. Methods: The efficacy (proportion identified as low risk based on baseline hs-cTnT<6 ng/L) of identifying low-risk patients was examined in a multicenter (n=22 sites) US cohort study of emergency department patients undergoing at least 1 hs-cTnT (CV Data Mart Biomarker cohort). We then determined the performance of a single hs-cTnT<6 ng/L (biomarker alone) to exclude acute myocardial injury (subsequent hs-cTnT >99th percentile in those with an initial hs-cTnT<6 ng/L). The clinically intended rule-out strategy combining a nonischemic ECG with a baseline hs-cTnT<6 ng/L was subsequently tested in an adjudicated cohort in which the diagnostic performance for ruling out acute myocardial infarction and safety (myocardial infarction or death at 30 days) were evaluated. Results: A total of 85 610 patients were evaluated in the CV Data Mart Biomarker cohort, among which 24 646 (29%) had a baseline hs-cTnT<6 ng/L. Women were more likely than men to have hs-cTnT<6 ng/L (38% versus 20%, P <0.0001). Among 11 962 patients with baseline hs-cTnT<6 ng/L and serial measurements, only 1.2% developed acute myocardial injury, resulting in a negative predictive value of 98.8% (95% CI, 98.6–99.0) and sensitivity of 99.6% (95% CI, 99.5–99.6). In the adjudicated cohort, a nonischemic ECG with hs-cTnT<6 ng/L identified 33% of patients (610/1849) as low risk and resulted in a negative predictive value and sensitivity of 100% and a 30-day rate of 0.2% for myocardial infarction or death. Conclusions: A single hs-cTnT below the limit of quantitation of 6 ng/L is a safe and rapid method to identify a substantial number of patients at very low risk for acute myocardial injury and infarction.