Diagnosis of acute myocardial infarction in patients with renal failure using high-sensitivity cardiac troponin T
Ola, Oluwabukola Mary , Akula, Ashok , Slusser, Josh, Mehta, Ramila A. , Crockford, Erika, Lobo, R , Hodge, Dave, Grube, Eric , Tak, Tahir , Cagin, C, Gulati, R, Sandoval, Yader , Jaffe, Allan S. , Knott, J, Ola, O, Michieli, Laura De , Grube, E, Jaffe, Allan S.

European Heart Journal | October 28, 2024 | Volume: 45 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehae666.1590 Get It

Abstract Background Diagnosing myocardial infarction (MI) in patients with chronic kidney disease (CKD) is difficult as these patients often have elevated baseline high-sensitivity cardiac troponin T (hs-cTnT) concentrations. Methods Observational U.S. cohort study of emergency department (ED) patients undergoing hs-cTnT measurement. Cases with >1 hs-cTnT increase >99th percentile were adjudicated following the Fourth Universal Definition of MI. Diagnostic performance of baseline and serial 2- and 6-hour hs-cTnT thresholds for ruling-in acute MI was compared between those without and with CKD (eGFR <60 ml/min/1.73m2). Results The study cohort included 1992 patients, amongst whom 501 (25%) had CKD. There were 701 (82%) patients with myocardial injury, 64 (7.5%) with type 1, and 91 (11%) with type 2 MI. In CKD patients with baseline hs-cTnT thresholds of >52, >100, >200 or >300 ng/L, PPVs for acute MI were 37% [95% CI 28-46], 53% (95% CI 39-67), 73% (95% CI 50-89) and 80% (95% CI 44-98), and in those without CKD, 64% (95% CI 50-77), 69% (95% CI 49-85), 59% (95% CI 33-82) and 54% (95% CI 25-81). In CKD patients with a 2-hour hs-cTnT delta of >10, >20 or >30 ng/L, the corresponding PPVs were 65% (95% CI 50-78), 86% (95% CI 68-96) and 88% (95% CI 68-97), and in those without CKD, 65% (95% CI 51-78), 73% (95% CI 57-86) and 75% (95% CI 58-88) (Figure). Conclusion Diagnostic performance of standard baseline and serial 2-hour hs-cTnT thresholds to rule-in MI is suboptimal in patients with CKD. It significantly improves when using higher baseline thresholds and delta values.
Diagnosis of acute myocardial infarction in patients with renal failure using high-sensitivity cardiac troponin T
Knott, Jonathan D , Ola, Olatunde , Michieli, Laura De , Akula, Ashok , Mehta, Ramila A. , Dworak, Marshall , Crockford, Erika, Lobo, Ronstan , Slusser, Joshua P. , Rastas, Nicholas, Karturi, Swetha, Wohlrab, Scott, Hodge, David O. , Grube, Eric , Tak, Tahir , Cagin, Charles , Gulati, Rajiv , Sandoval, Yader , Jaffe, Allan S. , De Michieli, Laura , Slusser, Joshua, Knott, Jonathan , Grube, Eric, Jaffe, Allan S.

European Heart Journal: Acute Cardiovascular Care | June 30, 2024 | Volume: 13 | Issue: 7 | Pages: 546-558

10.1093/ehjacc/zuae079 Get It

Abstract Aims Diagnosing myocardial infarction (MI) in patients with chronic kidney disease (CKD) is difficult as they often have increased high-sensitivity cardiac troponin T (hs-cTnT) concentrations. Methods and results Observational US cohort study of emergency department patients undergoing hs-cTnT measurement. Cases with ≥1 hs-cTnT increase > 99th percentile were adjudicated following the Fourth Universal Definition of MI. Diagnostic performance of baseline and serial 2 h hs-cTnT thresholds for ruling-in acute MI was compared between those without and with CKD (estimated glomerular filtration rate < 60 mL/min/1.73 m2). The study cohort included 1992 patients, amongst whom 501 (25%) had CKD. There were 75 (15%) and 350 (70%) patients with CKD and 80 (5%) and 351 (24%) without CKD who had acute MI and myocardial injury. In CKD patients with baseline hs-cTnT thresholds of ≥52, >100, >200, or >300 ng/L, positive predictive values (PPVs) for MI were 36% (95% CI 28–45), 53% (95% CI 39–67), 73% (95% CI 50–89), and 80% (95% CI 44–98), and in those without CKD, 61% (95% CI 47–73), 69% (95% CI 49–85), 59% (95% CI 33–82), and 54% (95% CI 25–81). In CKD patients with a 2 h hs-cTnT delta of ≥10, >20, or >30 ng/L, PPVs were 66% (95% CI 51–79), 86% (95% CI 68–96), and 88% (95% CI 68–97), and in those without CKD, 64% (95% CI 50–76), 73% (95% CI 57–86), and 75% (95% CI 58–88). Conclusion Diagnostic performance of standard baseline and serial 2 h hs-cTnT thresholds to rule-in MI is suboptimal in CKD patients. It significantly improves when using higher baseline thresholds and delta values.
Major adverse cardiovascular events after diagnosis of myocardial injury and types 1 and 2 myocardial infarction
Knott, Jonathan D , Ola, Olatunde , Akula, Ashok , Mehta, Ramila A. , Dworak, Marshall , Crockford, Erika, Lobo, Ronstan , Rastas, Nicholas, Karturi, Swetha, Wohlrab, Scott, Hodge, David O. , Grube, Eric , Tak, Tahir , Cagin, Charles , Gulati, Rajiv , Jaffe, Allan S. , Sandoval, Yader , Sandoval, Yader , Michieli, Laura De , Grube, Eric, Jaffe, Allan S.

European Heart Journal. Acute Cardiovascular Care | June 18, 2022 | Volume: 11 | Issue: 7 | Pages: 546-557

10.1093/ehjacc/zuac075 Get It

Abstract Aims Limited US outcome data exist among patients with myocardial injury and types 1 and 2 myocardial infarction (MI) evaluated with high-sensitivity cardiac troponin (hs-cTn). Methods and results This is an observational US cohort study of emergency department (ED) patients undergoing hs-cTnT measurement. Cases with ≥1 hs-cTnT increase >99th percentile were adjudicated following the Fourth Universal Definition of MI. Post-discharge major adverse cardiovascular events (MACE) included death, MI, heart failure (HF) hospitalization, stroke or transient ischaemic attack, and new-onset atrial fibrillation or flutter during 2 years follow-up. Among 2002 patients, 857 (43%) had ≥1 hs-cTnT >99th percentile. Among these, 702 (81.9%) had myocardial injury, 64 (7.5%) had type 1 MI, and 91 (10.6%) had type 2 MI. Compared with patients without myocardial injury, type 2 MI [8.4 vs. 50%; adjusted hazard ratio (HR) 2.31, 95% confidence interval (CI) 1.49–3.58] and myocardial injury (8.4 vs. 47%; adjusted HR 3.13, 95% CI 2.39–4.09) had a higher risk of MACE, in large part because of death and HF hospitalizations. Compared with patients with type 1 MI, type 2 MI (23 vs. 50%; adjusted HR 2.24; 95% CI 1.23–4.10) and myocardial injury (23 vs. 47%; adjusted HR 2.02; 95% CI 1.20–3.40) also have a higher risk of MACE. Conclusion Among unselected US ED patients undergoing hs-cTnT measurement, most increases are due to myocardial injury, and type 2 MI is more frequent than type 1 MI. Patients with myocardial injury and type 2 MI have morbid outcomes, in large part due to death and HF.
Rapid Exclusion of Acute Myocardial Injury and Infarction With a Single High-Sensitivity Cardiac Troponin T in the Emergency Department: A Multicenter United States Evaluation
Sandoval, Yader , Lewis, Bradley R., Mehta, Ramila A. , Ola, Olatunde , Knott, Jonathan D , Michieli, Laura De , Akula, Ashok , Lobo, Ronstan , Gharacholou, S. Michael , Dworak, Marshall , Crockford, Erika, Rastas, Nicholas, Grube, Eric , Karturi, Swetha, Wohlrab, Scott, Hodge, David O. , Tak, Tahir , Cagin, Charles , Gulati, Rajiv , Jaffe, Allan S. , Lewis, Bradley R , De Michieli, Laura , Dworak, Marshall , Gulati, Rajiv , Jaffe, Allan S. , Yang, Eric H. , Grube, Eric

Circulation | May 10, 2022 | Volume: 145 | Issue: 23 | Pages: 1708-1719

10.1161/circulationaha.122.059235 Get It

Background: There are good data to support using a single high-sensitivity cardiac troponin T (hs-cTnT) below the limit of detection of 5 ng/L to exclude acute myocardial infarction. Per the US Food and Drug Administration, hs-cTnT can only report to the limit of quantitation of 6 ng/L, a threshold for which there are limited data. Our goal was to determine whether a single hs-cTnT below the limit of quantitation of 6 ng/L is a safe strategy to identify patients at low risk for acute myocardial injury and infarction. Methods: The efficacy (proportion identified as low risk based on baseline hs-cTnT<6 ng/L) of identifying low-risk patients was examined in a multicenter (n=22 sites) US cohort study of emergency department patients undergoing at least 1 hs-cTnT (CV Data Mart Biomarker cohort). We then determined the performance of a single hs-cTnT<6 ng/L (biomarker alone) to exclude acute myocardial injury (subsequent hs-cTnT >99th percentile in those with an initial hs-cTnT<6 ng/L). The clinically intended rule-out strategy combining a nonischemic ECG with a baseline hs-cTnT<6 ng/L was subsequently tested in an adjudicated cohort in which the diagnostic performance for ruling out acute myocardial infarction and safety (myocardial infarction or death at 30 days) were evaluated. Results: A total of 85 610 patients were evaluated in the CV Data Mart Biomarker cohort, among which 24 646 (29%) had a baseline hs-cTnT<6 ng/L. Women were more likely than men to have hs-cTnT<6 ng/L (38% versus 20%, P <0.0001). Among 11 962 patients with baseline hs-cTnT<6 ng/L and serial measurements, only 1.2% developed acute myocardial injury, resulting in a negative predictive value of 98.8% (95% CI, 98.6–99.0) and sensitivity of 99.6% (95% CI, 99.5–99.6). In the adjudicated cohort, a nonischemic ECG with hs-cTnT<6 ng/L identified 33% of patients (610/1849) as low risk and resulted in a negative predictive value and sensitivity of 100% and a 30-day rate of 0.2% for myocardial infarction or death. Conclusions: A single hs-cTnT below the limit of quantitation of 6 ng/L is a safe and rapid method to identify a substantial number of patients at very low risk for acute myocardial injury and infarction.
P3594Transition from 4th to 5th generation cardiac troponin T: testing patterns, myocardial infarction incident rates, and resource utilization across a multicenter United States regional healthcare system
Sandoval, Yader , Askew, J. Wells , Newman, J., Grube, Eric , Ola, Oluwabukola Mary , Akula, Ashok , Wohlrab, Scott, Jaffe, Allan S. , Clements, Casey M. , Grube, E, Ola, O, Jaffe, Allan S.

European Heart Journal | October 21, 2019 | Volume: 40 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehz745.0454 Get It

Abstract Background Several high-sensitivity cardiac troponin (cTn) assays have been cleared by the United States (US) Food and Drug Administration (FDA) for clinical use. Although some of them have been used outside the US for some time, there is limited experience thus far across US sites. Following FDA clearance of the Roche 5th Gen cTnT assay in January 2017, a multicenter US regional healthcare system introduced this more sensitive cTnT assay into clinical practice in September 2018. Purpose To examine cTn testing patterns, incidence of acute myocardial infarction (MI), and resource utilization before and after implementation of the 5th Gen cTnT assay across a large US healthcare system. Methods Using electronic-health records reporting software (Cogito SlicerDicer, EPIC), administrative data was examined to evaluate the transition (4-months before and after implementation) from the 4th to 5th Gen cTnT assays across 16 hospitals but not the major hub hospital of the system that transitioned at a separate time. Adult patient visits (emergency and hospital encounters), cTnT testing, incidence of chest discomfort and acute MI, and resource utilization, including hospital admissions, were examined during the transition period. Results 98,558 adult ED patient visits occurred during an 8-month period across 16 hospitals, including 50,485 and 48,073 patient visits before (5/12/18 – 9/11/18) and after (9/12/18 – 1/11/19) implementation of the 5th Gen cTnT assay respectively. cTnT testing occurred in 20% (range 8.9–34.8%) of all ED visits, with testing performed in the absence of chest pain in 54% (range 37–67%) of cases. Acute MI was diagnosed in 5.6% (n=561) of cases using the 4th Gen cTnT assay as compared to 6.6% (n=608) of cases using the 5th Gen cTnT assay (absolute difference 1.0%, 95% CI: 0.32–1.68, p=0.004). Much of the increase in MI diagnoses were in women (2.2% vs. 2.8%, p=0.008). The proportion of ED patients requiring hospital admission did not differ between pre- and post-implementation periods (24.1% vs. 23.6%, p=0.4); however, among the subset of patients with chest pain, fewer admissions occurred post-implementation (17.9% vs. 15.8%, p=0.006). There was no increase in echocardiography (9.3% vs. 8.4%), coronary angiography (2.9% vs. 3.1%), or cardiac consultations (7.3% vs. 7.3%) utilization post-implementation. Conclusions Cardiac troponin testing occurs in nearly 20% of ED visits in a large multicenter regional healthcare system. About half of all tests are ordered in the absence of chest pain, with a low MI rate observed among the patients undergoing testing. Following implementation of the 5th Gen cTnT assay, testing rates/patterns remained unchanged, with a small but significant increase in MI diagnoses, primarily due to more women being diagnosed with MI. Fewer ED patients with chest pain required admission. Despite using a more sensitive cTn assay, hospital admissions and resource utilization did not increase post-implementation.