AbstractBackgroundDespite optimal medical therapy and cardiac resynchronization therapy (CRT), significant functional mitral regurgitation (MR) persisted in 30% of the patients and labeled as CRT nonresponders.AimsWe sought to study the impact of transcatheter edge‐to‐edge repair (TEER) in patients with symptomatic grade III and IV functional MR despite CRT.MethodsA retrospective analysis was conducted of all patients who had prior CRT for at least 6 months and underwent TEER for significant residual functional MR (grade ≥3) and symptomatic heart failure (HF) at our institution. The primary outcomes were the change in New York Heart Association classification (NYHA), MR grade, echo parameters, and NT‐ProBNP from baseline to 1‐year post‐procedure.ResultsA total of 28 patients were identified, mean age of 73 ± 6.7 years and 89% males. Procedure success was achieved in all patients. At 1‐year follow‐up, patients had lower MR grade (median 2, IQR 1 [1,2] vs. 4, IQR 1 [3,4]; p < 0.001), NYHA class (median 2, IQR 1 [2,3] vs. 3, IQR 1 [3,4]; p < 0.001), and NT‐ProBNP (7658 ± 11322 vs. 3760 ± 4431; p = 0.035) compared to before the TEER procedure. The left ventricular end‐diastolic volume (255 ± 59 vs. 244 ± 66 mm; p = 0.016) and the right ventricular systolic pressure (52 ± 14 mmHg vs. 37 ± 13 mmHg, <0.001) decreased.ConclusionPatients who remain symptomatic after CRT with severe functional MR had improved functional status and MR grade at 1‐year following TEER. There was a signal toward reverse remodeling.
High Lp(a) levels are a potential risk factor for aortic valve interventions in patients with bicuspid aortic valve
Abstract Background Bicuspid aortic valve (BAv) is associated with increased oxidative stress and inflammation, resulting in valve fibrosis, calcification, and ultimately early degenerative valve disease, often necessitating premature aortic valve intervention. In recent years, growing evidence has been published supporting the role of lipoprotein(a) [Lp(a)], an important carrier of oxidized phospholipids, in the development of aortic valve disease in the general population. However, the specific influence of Lp(a) levels in patients with BAv remains to be firmly established. Purpose To assess the role of Lp(a) levels in the development of aortic valve disease and the necessity for aortic valve interventions among individuals with BAv. Methods This retrospective multicenter study encompassed consecutive patients diagnosed with BAv from January 1997 to December 2022, all of whom had undergone serum Lp(a) measurement. This study evaluated the association between Lp(a) concentrations and the occurrence of aortic valve interventions. A cutoff point of ≥30 mg/dl for high Lp(a) levels was established. Binary logistic regression was utilized to calculate the odds ratio (OR) for an aortic intervention according to high versus low Lp(a) levels. Additionally, Kaplan Meier curves were employed to estimate the cumulative requirement for an aortic valve replacement based on Lp(a) concentrations. Results A total of 452 patients with BAv and a Lp(a) measurement were included in the study, with a mean age of 37.2 ±10.5 years at the time of BAv diagnosis, with 71.2% being male. Among these, 101 (22.3%) patients underwent an aortic valve replacement. In 72 cases (71.3%) aortic stenosis was the primary indication for intervention, while aortic regurgitation accounted for 29 cases (28.7%). The presence of elevated Lp(a) levels (≥30 mg/dl) demonstrated a significant association with the requirement for an aortic valve intervention (OR 2.2, 95%CI 1.4-3.6, p<0.001) in both the regression analysis and using the Kaplan-Meier estimator (Figure). High Lp(a) concentrations posed a risk factor for aortic valve replacements regardless of whether the primary indication for intervention was significant stenosis (OR 1.8, 95%CI 1.1-3.1, p=0.028) or regurgitation (OR 2.5, 95%CI 1.2-5.4, p=0.018). Conclusion Increased concentrations of Lp(a) may influence the clinical trajectory of patients with a BAv and may be a significant risk factor for aortic valve replacement, irrespective of the primary indication for intervention. Further investigations will be critical in unveiling the precise pathological mechanisms of Lp(a) in BAv. Confirming whether reducing Lp(a) levels could slow the progression of aortic disease in this demographic requires further exploration. Kaplan-Meier estimator.
Trends and Disparities in Valvular Heart Disease Mortality in the United States From 1999 to 2020
Background Percutaneous heart valve procedures have been increasingly performed over the past decade, yet real‐world mortality data on valvular heart disease (VHD) in the United States remain limited. Methods and Results We queried the Centers for Disease Control and Prevention's Wide‐Ranging Online Data for Epidemiologic Research database among patients ≥15 years old from 1999 to 2020. VHD and its subtypes were listed as the underlying cause of death. We calculated age‐adjusted mortality rate (AAMR) per 100 000 individuals and determined overall trends by estimating the average annual percent change using the Joinpoint regression program. Subgroup analyses were performed based on demographic and geographic factors. In the 22‐year study, there were 446 096 VHD deaths, accounting for 0.80% of all‐cause mortality (56 014 102 people) and 2.38% of the total cardiovascular mortality (18 759 451 people). Aortic stenosis recorded the highest mortality of VHD‐related death in both male (109 529, 61.74%) and female (166 930, 62.13%) populations. The AAMR of VHD has declined from 8.4 (95% CI, 8.2–8.5) to 6.6 (95% CI, 6.5–6.7) per 100 000 population. Similar decreasing AAMR trends were also seen for the VHD subtypes. Men recorded higher AAMR for aortic stenosis and aortic regurgitation, whereas women had higher AAMR for mitral stenosis and mitral regurgitation. Mitral regurgitation had the highest change in average annual percent change in AAMR. Conclusions The mortality rate of VHD among the US population has declined over the past 2 decades. This highlights the likely efficacy of increasing surveillance and advancement in the management of VHD, resulting in improved outcomes.
Cardiac Allograft Vasculopathy: Challenges and Advances in Invasive and Non-Invasive Diagnostic Modalities
Cardiac allograft vasculopathy (CAV) is a distinct form of coronary artery disease that represents a major cause of death beyond the first year after heart transplantation. The pathophysiology of CAV is still not completely elucidated; it involves progressive circumferential wall thickening of both the epicardial and intramyocardial coronary arteries. Coronary angiography is still considered the gold-standard test for the diagnosis of CAV, and intravascular ultrasound (IVUS) can detect early intimal thickening with improved sensitivity. However, these tests are invasive and are unable to visualize and evaluate coronary microcirculation. Increasing evidence for non-invasive surveillance techniques assessing both epicardial and microvascular components of CAV may help improve early detection. These include computed tomography coronary angiography (CTCA), single-photon emission computed tomography (SPECT), positron emission tomography (PET), and vasodilator stress myocardial contrast echocardiography perfusion imaging. This review summarizes the current state of diagnostic modalities and their utility and prognostic value for CAV and also evaluates emerging tools that may improve the early detection of this complex disease.
The prognostic value of artificial intelligence to predict cardiac amyloidosis in patients with severe aortic stenosis undergoing transcatheter aortic valve replacement
Abstract Aims Cardiac amyloidosis (CA) is common in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR). Cardiac amyloidosis has poor outcomes, and its assessment in all TAVR patients is costly and challenging. Electrocardiogram (ECG) artificial intelligence (AI) algorithms that screen for CA may be useful to identify at-risk patients. Methods and results In this retrospective analysis of our institutional National Cardiovascular Disease Registry (NCDR)-TAVR database, patients undergoing TAVR between January 2012 and December 2018 were included. Pre-TAVR CA probability was analysed by an ECG AI predictive model, with >50% risk defined as high probability for CA. Univariable and propensity score covariate adjustment analyses using Cox regression were performed to compare clinical outcomes between patients with high CA probability vs. those with low probability at 1-year follow-up after TAVR. Of 1426 patients who underwent TAVR (mean age 81.0 ± 8.5 years, 57.6% male), 349 (24.4%) had high CA probability on pre-procedure ECG. Only 17 (1.2%) had a clinical diagnosis of CA. After multivariable adjustment, high probability of CA by ECG AI algorithm was significantly associated with increased all-cause mortality [hazard ratio (HR) 1.40, 95% confidence interval (CI) 1.01–1.96, P = 0.046] and higher rates of major adverse cardiovascular events (transient ischaemic attack (TIA)/stroke, myocardial infarction, and heart failure hospitalizations] (HR 1.36, 95% CI 1.01–1.82, P = 0.041), driven primarily by heart failure hospitalizations (HR 1.58, 95% CI 1.13–2.20, P = 0.008) at 1-year follow-up. There were no significant differences in TIA/stroke or myocardial infarction. Conclusion Artificial intelligence applied to pre-TAVR ECGs identifies a subgroup at higher risk of clinical events. These targeted patients may benefit from further diagnostic evaluation for CA.
Combined Endocardial and Epicardial Ablation of Drug-Refractory Ventricular Tachycardia by Direct Ventricular Puncture
Mechanical valves in both aortic and mitral positions pose a challenge for left ventricular (LV) access during ventricular tachycardia (VT) ablation using the antegrade transseptal or the retrograde transaortic approach. A 57 year-old male with ischemic cardiomyopathy, mechanical aortic and mitral valves, and recurrent VT underwent a combined endocardial and epicardial ablation via direct ventricular puncture via mini-thoracotomy. Successful mapping with endocardial and epicardial ablation was performed, with no recurrent VT on follow up. We showcase the feasibility of VT ablation using an open transapical approach for patients with mechanical aortic and mitral valves.
Abstract 13182: Comparison of Actual and Theoretical Aortic Valve Calcium Score to Assess TAVR Referral Delay in Patients With Atrial Fibrillation
Introduction: Doppler mean gradient (MG) can underestimate the severity of aortic stenosis (AS) in patients with atrial fibrillation (AF) compared to patients in sinus rhythm (SR). Patients with AF and severe AS may experience delayed diagnosis and more advanced disease at time of referral for transcatheter aortic valve replacement (TAVR). Methods: Patients who underwent TAVR from 2013 to 2017 for native valve severe AS were identified from an institutional database. MG and aortic valve calcium score (AVCS) at time of referral were compared in patients in AF and SR. Retrospective theoretical AVCS in AF patients were derived assuming an average progression of 152 AU/year (published data). Results: There were 820 patients included; mean age was 81.3+/- 8.2 years and 41.6% were female. AF was present in 356 patients at time of referral. Patients in AF were older (82.2 vs. 80.5, p = 0.003), had lower MG compared to SR patients (42.0 vs. 44.9, p = 0.002) and a lower peak velocity (4.1 vs. 4.2, p = 0.010) with a similar indexed aortic valve area (0.4 vs. 0.4, p = 0.17). Stratified by sex, the median calcium score for AF patients was higher (by around 300 AU) among both males (AF 2850.0 vs. SR 2561.0, p = 0.044) and females (AF 1942.0 vs. 1610.5, p = 0.025) ( figure 1 ). A density plot of retrospective theoretical AVCS in AF patients (projected assuming referral to TAVR approximately two years prior) resulted in nearly identical median AVCS between the two cohorts ( figure 2 ). Conclusions: Older age and higher AVCS in patients with AF compared to SR suggests that AS was both underestimated and more advanced at time of referral to TAVR. Patients in AF may have severe AS as early as 2 years prior to TAVR referral.
The role of serum lipoprotein(a) levels in bioprosthetic aortic valve degeneration
Abstract Introduction Lipoprotein(a) [Lp(a)] is associated with an increased incidence of aortic stenosis. Bioprosthetic aortic valve degeneration and native aortic stenosis share similar pathological mechanisms. Evidence regarding the role of serum Lp(a) concentrations in bioprosthetic aortic valve degeneration is lacking. Purpose To evaluate the association between serum Lp(a) concentrations and bioprosthetic aortic valve degeneration. Methods In this retrospective multicenter study, consecutive patients who underwent a bioprosthetic aortic valve replacement between Jan-2010 and Dec-2020 and had a preoperatory serum Lp(a) measurement were included. A baseline transthoracic echocardiography (TTE) was performed following the aortic valve replacement and a follow-up TTE was performed at least 24 months after the baseline study to determine the presence of bioprosthetic valve degeneration. Significant degeneration was defined as: (a) an increase >10 mmHg in mean bioprosthetic aortic valve gradient from baseline status + a decrease in effective orifice area + a decrease in Doppler velocity index + exclusion of clinically thrombotic leaflet thickening, OR (b) new moderate or severe prosthetic aortic regurgitation (if the main component was periprosthetic, then it was not considered). Lp(a) concentrations were compared between patients with and without degeneration and regression analysis was conducted to investigate the association between bioprosthetic valve degeneration and Lp(a) levels. Results In total, 211 cases were included (mean age 74.1 ±9.4 years, 72.0% males, 29.9% transcatheter aortic valve replacements) (Figure 1). Median time between baseline and follow-up TTE was 5.0 (IQR 3.7) years. Bioprostheses degeneration was observed in 33 (15.6%) patients at follow-up. Median serum levels of Lp(a) were significantly higher in the patients affected by degeneration versus non-affected cases (50.0 vs 15.7 mg/dl, p=0.003). In the regression analysis, high Lp(a) levels (≥30 mg/dl) were associated with degeneration both in a univariate analysis (OR 4.8, 95%CI 2.2-10.9, p<0.001) and multivariate analysis adjusted by other risk factors for bioprostheses degeneration (age, sex, hypertension, smoking, patient prosthesis mismatch, creatinine levels, and body surface area) (OR 5.2, 95%CI 2.1-12.8, p<0.001). Conclusion Serum Lp(a) concentrations seem to be a risk factor for bioprosthetic aortic valve degeneration (Figure 2). There is an increasing need to accurately predict bioprosthetic aortic valve degeneration and to develop novel methods and treatments to increase their durability. Prospective studies are needed to confirm these findings and to investigate whether lowering Lp(a) could slow bioprostheses degradation.Population characteristicsLp(a) and bioprostheses degeneration
Left ventricle outflow tract obstruction after transcatheter mitral valve replacement with a transatrial approach