Impact of proton PBS machine operating parameters on the effectiveness of layer rescanning for interplay effect mitigation in lung SBRT treatment
Liang, Xiaoying , Flampouri, Stella , Park, Justin C., Yaddanapudi, Sridhar , Tan, Jun , Beltran, Chris , Tan, Jun , Shen, Jiajian , Yaddanapudi, Sridhar , Beltran, Chris J , Liang, Xiaoying , Liu, Chunbo , Shen, Jiajian , Lu, Bo, Furutani, Keith M. , Tan, Jun

Journal of Applied Clinical Medical Physics | April 9, 2024 | Volume: 25 | Issue: 7 | Pages: No page available

10.1002/acm2.14342 Get It

Abstract Background Rescanning is a common technique used in proton pencil beam scanning to mitigate the interplay effect. Advances in machine operating parameters across different generations of particle therapy systems have led to improvements in beam delivery time (BDT). However, the potential impact of these improvements on the effectiveness of rescanning remains an underexplored area in the existing research. Methods We systematically investigated the impact of proton machine operating parameters on the effectiveness of layer rescanning in mitigating interplay effect during lung SBRT treatment, using the CIRS phantom. Focused on the Hitachi synchrotron particle therapy system, we explored machine operating parameters from our institution's current (2015) and upcoming systems (2025A and 2025B). Accumulated dynamic 4D dose were reconstructed to assess the interplay effect and layer rescanning effectiveness. Results Achieving target coverage and dose homogeneity within 2% deviation required 6, 6, and 20 times layer rescanning for the 2015, 2025A, and 2025B machine parameters, respectively. Beyond this point, further increasing the number of layer rescanning did not further improve the dose distribution. BDTs without rescanning were 50.4, 24.4, and 11.4 s for 2015, 2025A, and 2025B, respectively. However, after incorporating proper number of layer rescanning (six for 2015 and 2025A, 20 for 2025B), BDTs increased to 67.0, 39.6, and 42.3 s for 2015, 2025A, and 2025B machine parameters. Our data also demonstrated the potential problem of false negative and false positive if the randomness of the respiratory phase at which the beam is initiated is not considered in the evaluation of interplay effect. Conclusion The effectiveness of layer rescanning for mitigating interplay effect is affected by machine operating parameters. Therefore, past clinical experiences may not be applicable to modern machines.
Investigation of scan path optimization in improving proton pencil beam scanning continuous delivery
Liu, Chunbo , Beltran, Chris , Park, Chunjoo, Yaddanapudi, Sridhar , Tan, Jun , Furutani, Keith M. , Liang, Xiaoying , Tan, Jun , Shen, Jiajian , Furutani, Keith M , Liang, Xiaoying , Beltran, Chris J , Yaddanapudi, Sridhar , Shen, Jiajian , Lu, Bo, Tan, Jun

Physics in Medicine & Biology | September 13, 2023 | Volume: 68 | Issue: 19 | Pages: 195023

10.1088/1361-6560/acf98e Get It

Abstract Objective . To investigate the impact of scan path optimization on the dose accuracy and beam delivery time (BDT) of proton pencil beam scanning in the dose-driven continuous scanning (DDCS). Approach . A diverse set of six clinical plans, representing various spot patterns and treatment sites, was used to evaluate the effectiveness of scan time optimization and scan length optimization. The DDCS dose discrepancy and BDT with optimized scan paths was compared to the default serpentine scan path. Main results . Both scan time optimization and scan path optimization were able to reduce the DDCS dose discrepancy compared to the default serpentine scan path. All plans, except for the layer repainting lung plan, achieved a 2%/2 mm gamma pass rate of over 99% and less than 1% PTV DVH root mean square error (RMSE) through scan path optimization. In the case of the layer repainting lung plan, when compared to the default serpentine scan path, the 2%/2 mm gamma pass rate showed improvements from 91.3% to 93.1% and 95.8%, while the PTV DVH RMSE decreased from 2.1% to 1.7% and 1.1% for scan time optimization and scan length optimization, respectively. Although scan time optimization resulted in shorter total scan times for all plans compared to the default scan path and scan length optimization tended to have longer total scan times. However, due to the short total scan times and their minimal contribution to the total BDT, the impact of scan path optimization on the total BDT was practically negligible. Significance . Both scan time optimization and scan length optimization proved to be effective in minimizing DDCS dose discrepancy. No definitive winner can be determined between these two optimization approaches. Both scan time and scan length optimization had minimal effect on the total BDT.
A high‐resolution cone beam computed tomography (HRCBCT) reconstruction framework for CBCT‐guided online adaptive therapy
Park, Justin C., Song, Bongyong , Lü, Bo , Tan, Jun , Parisi, Alessio , Denbeigh, Janet M. , Yaddanpudi, Sridhar, ByongSu, Choi, Kim, Jin Sung , Beltran, Chris , Yaddanapudi, Sridhar , Tan, Jun , Denbeigh, Janet, Choi, Byongsu , Beltran, Chris J , Parisi, Alessio , Yaddanapudi, Sridhar , Liang, Xiaoying , Choi, Byongsu, Furutani, Keith M. , Tan, Jun

Medical Physics | September 10, 2023 | Volume: 50 | Issue: 10 | Pages: 6490-6501

10.1002/mp.16734 Get It

AbstractBackgroundKilo‐voltage cone‐beam computed tomography (CBCT) is a prevalent modality used for adaptive radiotherapy (ART) due to its compatibility with linear accelerators and ability to provide online imaging. However, the widely‐used Feldkamp‐Davis‐Kress (FDK) reconstruction algorithm has several limitations, including potential streak aliasing artifacts and elevated noise levels. Iterative reconstruction (IR) techniques, such as total variation (TV) minimization, dictionary‐based methods, and prior information‐based methods, have emerged as viable solutions to address these limitations and improve the quality and applicability of CBCT in ART.PurposeOne of the primary challenges in IR‐based techniques is finding the right balance between minimizing image noise and preserving image resolution. To overcome this challenge, we have developed a new reconstruction technique called high‐resolution CBCT (HRCBCT) that specifically focuses on improving image resolution while reducing noise levels.MethodsThe HRCBCT reconstruction technique builds upon the conventional IR approach, incorporating three components: the data fidelity term, the resolution preservation term, and the regularization term. The data fidelity term ensures alignment between reconstructed values and measured projection data, while the resolution preservation term exploits the high resolution of the initial Feldkamp‐Davis‐Kress (FDK) algorithm. The regularization term mitigates noise during the IR process. To enhance convergence and resolution at each iterative stage, we applied Iterative Filtered Backprojection (IFBP) to the data fidelity minimization process.ResultsWe evaluated the performance of the proposed HRCBCT algorithm using data from two physical phantoms and one head and neck patient. The HRCBCT algorithm outperformed all four different algorithms; FDK, Iterative Filtered Back Projection (IFBP), Compressed Sensing based Iterative Reconstruction (CSIR), and Prior Image Constrained Compressed Sensing (PICCS) methods in terms of resolution and noise reduction for all data sets. Line profiles across three line pairs of resolution revealed that the HRCBCT algorithm delivered the highest distinguishable line pairs compared to the other algorithms. Similarly, the Modulation Transfer Function (MTF) measurements, obtained from the tungsten wire insert on the CatPhan 600 physical phantom, showed a significant improvement with HRCBCT over traditional algorithms.ConclusionThe proposed HRCBCT algorithm offers a promising solution for enhancing CBCT image quality in adaptive radiotherapy settings. By addressing the challenges inherent in traditional IR methods, the algorithm delivers high‐definition CBCT images with improved resolution and reduced noise throughout each iterative step. Implementing the HR CBCT algorithm could significantly impact the accuracy of treatment planning during online adaptive therapy.
Selecting Optimal Proton Pencil Beam Scanning Plan Parameters to Reduce Dose Discrepancy between Discrete Spot Plan and Continuous Scanning: A Proof-of-Concept Study
Beltran, Chris , Park, Chunjoo, Yaddanapudi, Sridhar , Tan, Jun , Furutani, Keith M. , Tan, Jun , Furutani, Keith M , Beltran, Chris J , Yaddanapudi, Sridhar , Liang, Xiaoying , Liu, Chunbo , Lu, Bo, Tan, Jun

Cancers | August 14, 2023 | Volume: 15 | Issue: 16 | Pages: 4084

10.3390/cancers15164084 Get It

Pencil beam scanning delivered with continuous scanning has several advantages over conventional discrete spot scanning. Such advantages include improved beam delivery efficiency and reduced beam delivery time. However, a move dose is delivered between consecutive spots with continuous scanning, and current treatment planning systems do not take this into account. Therefore, continuous scanning and discrete spot plans have an inherent dose discrepancy. Using the operating parameters of the state-of-the-art particle therapy system, we conducted a proof-of-concept study in which we systematically generated 28 plans for cubic targets with different combinations of plan parameters and simulated the dose discrepancies between continuous scanning and a planned one. A nomograph to guide the selection of plan parameters was developed to reduce the dose discrepancy. The effectiveness of the nomograph was evaluated with two clinical cases (one prostate and one liver). Plans with parameters guided by the nomograph decreased dose discrepancy than those used standard plan parameters. Specifically, the 2%/2 mm gamma passing rate increased from 96.3% to 100% for the prostate case and from 97.8% to 99.7% for the liver case. The CTV DVH root mean square error decreased from 2.2% to 0.2% for the prostate case and from 1.8% to 0.9% for the liver case. The decreased dose discrepancy may allow the relaxing of the delivery constraint for some cases, leading to greater benefits in continuous scanning. Further investigation is warranted.
Technical note: Progressive deep learning: An accelerated training strategy for medical image segmentation
ByongSu, Choi, Olberg, Sven, Park, Justin C., Kim, Jin Sung , Shrestha, Deepak K. , Yaddanapudi, Sridhar , Beltran, Chris , Yaddanapudi, Shridhar, Beltran, Chris J , Yaddanapudi, Sridhar , Choi, Byongsu, Furutani, Keith M.

Medical Physics | February 10, 2023 | Volume: 50 | Issue: 8 | Pages: 5075-5087

10.1002/mp.16267 Get It

AbstractBackgroundRecent advancements in Deep Learning (DL) methodologies have led to state‐of‐the‐art performance in a wide range of applications especially in object recognition, classification, and segmentation of medical images. However, training modern DL models requires a large amount of computation and long training times due to the complex nature of network structures and the large number of training datasets involved. Moreover, it is an intensive, repetitive manual process to select the optimized configuration of hyperparameters for a given DL network.PurposeIn this study, we present a novel approach to accelerate the training time of DL models via the progressive feeding of training datasets based on similarity measures for medical image segmentation. We term this approach Progressive Deep Learning (PDL).MethodsThe two‐stage PDL approach was tested on the auto‐segmentation task for two imaging modalities: CT and MRI. The training datasets were ranked according to similarity measures between each sample based on Mean Square Error (MSE), Peak Signal‐to‐Noise Ratio (PSNR), Structural Similarity Index (SSIM), and the Universal Quality Image Index (UQI) values. At the start of the training process, a relatively coarse sampling of training datasets with higher ranks was used to optimize the hyperparameters of the DL network. Following this, the samples with higher ranks were used in step 1 to yield accelerated loss minimization in early training epochs and the total dataset was added in step 2 for the remainder of training.ResultsOur results demonstrate that the PDL approach can reduce the training time by nearly half (∼49%) and can predict segmentations (CT U‐net/DenseNet dice coefficient: 0.9506/0.9508, MR U‐net/DenseNet dice coefficient: 0.9508/0.9510) without major statistical difference (Wilcoxon signed‐rank test) compared to the conventional DL approach. The total training times with a fixed cutoff at 0.95 DSC for the CT dataset using DenseNet and U‐Net architectures, respectively, were 17 h, 20 min and 4 h, 45 min in the conventional case compared to 8 h, 45 min and 2 h, 20 min with PDL. For the MRI dataset, the total training times using the same architectures were 2 h, 54 min and 52 min in the conventional case and 1 h, 14 min and 25 min with PDL.ConclusionThe proposed PDL training approach offers the ability to substantially reduce the training time for medical image segmentation while maintaining the performance achieved in the conventional case.
Investigation of beam delivery time for synchrotron-based proton pencil beam scanning system with novel scanning mode
Liang, Xiaoying , Liu, Chunbo , Shen, Jiajian , Bues, Martin , Dougherty, Jingjing M. , Parisi, Alessio , Shrestha, Deepak K. , Yaddanpudi, Sridhar, Beltran, Chris , Yaddanapudi, Sridhar , Furutani, Keith M. , Shen, Jiajian , Bues, Martin , Dougherty, Jingjing M , Parisi, Alessio , Beltran, Chris J , Liang, Xiaoying , Yaddanapudi, Sridhar , Li, Heng

Physics in Medicine & Biology | July 25, 2022 | Volume: 67 | Issue: 17 | Pages: 175001

10.1088/1361-6560/ac8410 Get It

Abstract Objective. To investigate synchrotron-based proton pencil beam scanning (PBS) beam delivery time (BDT) using novel continuous scanning mode. Approach. A BDT calculation model was developed for the Hitachi particle therapy system. The model was validated against the measured BDT of 36 representative clinical proton PBS plans with discrete spot scanning (DSS) in the current Hitachi proton therapy system. BDTs were calculated with the next generation using Mayo Clinic Florida system operating parameters for conventional DSS, and novel dose driven continuous scanning (DDCS). BDTs of DDCS with and without Break Spots were investigated. Main results. For DDCS without Break Spots, the use of Stop Ratio to control the transit dose largely reduced the beam intensity and consequently, severely prolonged the BDT. DDCS with Break Spots was able to maintain a sufficiently high beam intensity while controlling transit dose. In DDCS with Break Spots, tradeoffs were made between beam intensity and number of Break Spots. Therefore, BDT decreased with increased beam intensity but reached a plateau for beam intensity larger than 10 MU s −1 . Averaging over all clinical plans, BDT was reduced by 10% for DDCS with Break Spots compared to DSS. Significance. DDCS with Break Spots reduced BDT. DDCS has the potential to further reduce BDT under the ideal scenario which requests both stable beam intensity extraction and accurately modelling the transit dose. Further investigation is warranted.
Electronic charting of radiation therapy planning and treatment: Report of Task Group 262
Santos, Luis E. Fong de los, Fontenla, Sandra, Hanley, Joseph, Harwalkar, Vijay A., Hong, Linda , Huang, Y. Jessica , Kim, Grace Gwe‐Ya, Richardson, Susan , Sutlief, Steven , Yaddanapudi, Sridhar , Merkel, Sue, Parry, Mark D., Fong de Los Santos, Luis E, Parry, Mark, Yaddanapudi, Sridhar , Mechalakos, James , Dieterich, Sonja , Kim, Grace Gwe‐Ya

Medical Physics | July 20, 2021 | Volume: 48 | Issue: 11 | Pages: No page available

10.1002/mp.15116 Get It

AbstractWhile most Radiation Oncology clinics have adopted electronic charting in one form or another, no consensus document exists that provides guidelines for safe and effective use of the Radiation Oncology electronic medical records (RO‐EMR). Task Group 262 was formed to provide these guidelines as well as to provide recommendations to vendors for improving electronic charting functionality in future. Guidelines are provided in the following areas: Implementation and training for the RO‐EMR, acceptance testing and quality assurance (QA) of the RO‐EMR, use of the RO‐EMR as an information repository, use of the RO‐EMR as a workflow manager, electronic charting for brachytherapy and nonstandard treatments, and information technology (IT) considerations associated with the RO‐EMR. The report was based on a literature search by the task group, an extensive survey of task group members on their respective RO‐EMR practices, an AAPM membership survey on electronic charting, as well as group consensus.