Citations 81

Deep Brain Stimulation: Technology at the Cutting Edge
Shah, Rahul S. , Chang, Su-Youne , Min, Hoon‐Ki , Cho, Zang‐Hee , Blaha, Charles D. , Lee, Kendall H. , Min, Hoon-Ki Paul , Blaha, Charles

Journal of Clinical Neurology | January 20, 2011 | Volume: 6 | Issue: 4 | Pages: 167

10.3988/jcn.2010.6.4.167 Get It

Unsupervised Classification of High-Frequency Oscillations in Human Neocortical Epilepsy and Control Patients
Blanco, Justin A. , Stead, Matt, Krieger, Abba Μ. , Viventi, Jonathan , Marsh, W. Richard , Lee, Kendall H. , Litt, Brian , Worrell, Gregory A.

Journal of Neurophysiology | September 2, 2010 | Volume: 104 | Issue: 5 | Pages: 2900-2912

10.1152/jn.01082.2009 Get It

High-frequency oscillations (HFOs) have been observed in animal and human intracranial recordings during both normal and aberrant brain states. It has been proposed that the relationship between subclasses of these oscillations can be used to identify epileptic brain. Studies of HFOs in epilepsy have been hampered by selection bias arising primarily out of the need to reduce the volume of data so that clinicians can manually review it. In this study, we introduce an algorithm for detecting and classifying these signals automatically and demonstrate the tractability of analyzing a data set of unprecedented size, over 31,000 channel-hours of intracranial electroencephalographic (iEEG) recordings from micro- and macroelectrodes in humans. Using an unsupervised approach that does not presuppose a specific number of clusters in the data, we show direct evidence for the existence of distinct classes of transient oscillations within the 100- to 500-Hz frequency range in a population of nine neocortical epilepsy patients and two controls. The number of classes we find, four (three plus one putative artifact class), is consistent with prior studies that identify “ripple” and “fast ripple” oscillations using human-intensive methods and, additionally, identifies a less examined class of mixed-frequency events.
Surgically treated movement disorders associated with heterotopia
Mullin, Jeffrey P. , Lee, Kendall H. , Meyer, Fredric B. , Stead, Matt, Gompel, Jamie J. Van

Journal of Neurosurgery: Pediatrics | September 1, 2010 | Volume: 6 | Issue: 3 | Pages: 267-272

10.3171/2010.5.peds10220 Get It

Heterotopic gray matter has been implicated in epilepsy; however, not much is known regarding heterotopia beyond epilepsy. Here, the authors describe 2 pediatric patients with deep heterotopias contiguous with basal ganglia structures. These heterotopias appear to have manifested as movement disorders. One patient presented with a left-sided myoclonus and choreiform movements associated with a right caudate heterotopia; she experienced vast improvement after resection of periventricular heterotopia. The other patient presented with progressive dystonia and a ballistic movement disorder. Initial bilateral globus pallidus internus stimulation resulted in successful treatment of the dystonia; however, her movement disorder worsened. After an extensive workup, including STATISCOM (statistical ictal SPECT coregistered to MR imaging), the patient underwent cortical stimulation with improvement in her movement disorder. To the best of our knowledge, these cases are the first reported instances of heterotopic gray matter associated with movement disorders. Both patients experienced significant improvements following resection of their heterotopias.
Development of intraoperative electrochemical detection: wireless instantaneous neurochemical concentration sensor for deep brain stimulation feedback
Chang, Su-Youne , Goerss, Stephan J., Kimble, Christopher J., Bennet, Kevin E. , Lee, Kendall H. , Gompel, Jamie J. Van , Kim, In

Neurosurgical Focus | July 30, 2010 | Volume: 29 | Issue: 2 | Pages: E6

10.3171/2010.5.focus10110 Get It

Deep brain stimulation (DBS) is effective when there appears to be a distortion in the complex neurochemical circuitry of the brain. Currently, the mechanism of DBS is incompletely understood; however, it has been hypothesized that DBS evokes release of neurochemicals. Well-established chemical detection systems such as microdialysis and mass spectrometry are impractical if one is assessing changes that are happening on a second-to-second time scale or for chronically used implanted recordings, as would be required for DBS feedback. Electrochemical detection techniques such as fast-scan cyclic voltammetry (FSCV) and amperometry have until recently remained in the realm of basic science; however, it is enticing to apply these powerful recording technologies to clinical and translational applications. The Wireless Instantaneous Neurochemical Concentration Sensor (WINCS) currently is a research device designed for human use capable of in vivo FSCV and amperometry, sampling at subsecond time resolution. In this paper, the authors review recent advances in this electrochemical application to DBS technologies. The WINCS can detect dopamine, adenosine, and serotonin by FSCV. For example, FSCV is capable of detecting dopamine in the caudate evoked by stimulation of the subthalamic nucleus/substantia nigra in pig and rat models of DBS. It is further capable of detecting dopamine by amperometry and, when used with enzyme linked sensors, both glutamate and adenosine. In conclusion, WINCS is a highly versatile instrument that allows near real-time (millisecond) detection of neurochemicals important to DBS research. In the future, the neurochemical changes detected using WINCS may be important as surrogate markers for proper DBS placement as well as the sensor component for a “smart” DBS system with electrochemical feedback that allows automatic modulation of stimulation parameters. Current work is under way to establish WINCS use in humans.
Wireless Instantaneous Neurotransmitter Concentration System: electrochemical monitoring of serotonin using fast-scan cyclic voltammetry—a proof-of-principle study
Griessenauer, Christoph J. , Chang, Su-Youne , Tye, Susannah J. , Kimble, Christopher J., Bennet, Kevin E. , Garris, Paul A. , Lee, Kendall H. , Tye, Susannah J , Griessenauer, Christoph J

Journal of Neurosurgery | April 23, 2010 | Volume: 113 | Issue: 3 | Pages: 656-665

10.3171/2010.3.jns091627 Get It

Object The authors previously reported the development of the Wireless Instantaneous Neurotransmitter Concentration System (WINCS) for measuring dopamine and suggested that this technology may be useful for evaluating deep brain stimulation–related neuromodulatory effects on neurotransmitter systems. The WINCS supports fast-scan cyclic voltammetry (FSCV) at a carbon-fiber microelectrode (CFM) for real-time, spatially resolved neurotransmitter measurements. The FSCV parameters used to establish WINCS dopamine measurements are not suitable for serotonin, a neurotransmitter implicated in depression, because they lead to CFM fouling and a loss of sensitivity. Here, the authors incorporate into WINCS a previously described N-shaped waveform applied at a high scan rate to establish wireless serotonin monitoring. Methods Optimized for the detection of serotonin, FSCV consisted of an N-shaped waveform scanned linearly from a resting potential of +0.2 to +1.0 V, then to −0.1 V and back to +0.2 V, at a rate of 1000 V/second. Proof-of-principle tests included flow injection analysis and electrically evoked serotonin release in the dorsal raphe nucleus of rat brain slices. Results Flow cell injection analysis demonstrated that the N waveform, applied at a scan rate of 1000 V/second, significantly reduced serotonin fouling of the CFM, relative to that observed with FSCV parameters for dopamine. In brain slices, WINCS reliably detected subsecond serotonin release in the dorsal raphe nucleus evoked by local high-frequency stimulation. Conclusions The authors found that WINCS supported high-fidelity wireless serotonin monitoring by FSCV at a CFM. In the future such measurements of serotonin in large animal models and in humans may help to establish the mechanism of deep brain stimulation for psychiatric disease.
Direct visualization of deep brain stimulation targets in Parkinson disease with the use of 7-tesla magnetic resonance imaging
Cho, Zang‐Hee , Min, Hoon‐Ki , Oh, Se‐Hong , Han, Jae-Yong, Park, Chan-Woong, Chi, Je-Geun, Kim, Young-Bo , Paek, Sun Ha , Lozano, Andrés M. , Lee, Kendall H. , Min, Hoon-Ki Paul

Journal of Neurosurgery | April 9, 2010 | Volume: 113 | Issue: 3 | Pages: 639-647

10.3171/2010.3.jns091385 Get It

Object A challenge associated with deep brain stimulation (DBS) in treating advanced Parkinson disease (PD) is the direct visualization of brain nuclei, which often involves indirect approximations of stereotactic targets. In the present study, the authors compared T2*-weighted images obtained using 7-T MR imaging with those obtained using 1.5- and 3-T MR imaging to ascertain whether 7-T imaging enables better visualization of targets for DBS in PD. Methods The authors compared 1.5-, 3-, and 7-T MR images obtained in 11 healthy volunteers and 1 patient with PD. Results With 7-T imaging, distinct images of the brain were obtained, including the subthalamic nucleus (STN) and internal globus pallidus (GPi). Compared with the 1.5- and 3-T MR images of the STN and GPi, the 7-T MR images showed marked improvements in spatial resolution, tissue contrast, and signal-to-noise ratio. Conclusions Data in this study reveal the superiority of 7-T MR imaging for visualizing structures targeted for DBS in the management of PD. This finding suggests that by enabling the direct visualization of neural structures of interest, 7-T MR imaging could be a valuable aid in neurosurgical procedures.
Stereotactic electroencephalography with temporal grid and mesial temporal depth electrode coverage: does technique of depth electrode placement affect outcome?
Meyer, Fredric B. , Marsh, W. Richard , Lee, Kendall H. , Gompel, Jamie J. Van , Worrell, Gregory A.

Journal of Neurosurgery | February 19, 2010 | Volume: 113 | Issue: 1 | Pages: 32-38

10.3171/2009.12.jns091073 Get It

Object Intracranial monitoring for temporal lobe seizure localization to differentiate neocortical from mesial temporal onset seizures requires both neocortical subdural grids and hippocampal depth electrode implantation. There are 2 basic techniques for hippocampal depth electrode implantation. This first technique uses a stereotactically guided 8-contact depth electrode directed along the long axis of the hippocampus to the amygdala via an occipital bur hole. The second technique involves direct placement of 2 or 3 4-contact depth electrodes perpendicular to the temporal lobe through the middle temporal gyrus and overlying subdural grid. The purpose of this study was to determine whether one technique was superior to the other by examining monitoring success and complications. Methods Between 1997 and 2005, 41 patients underwent invasive seizure monitoring with both temporal subdural grids and depth electrodes placed in 2 ways. Patients in Group A underwent the first technique, and patients in Group B underwent the second technique. Results Group A consisted of 26 patients and Group B 15 patients. There were no statistically significant differences between Groups A and B regarding demographics, monitoring duration, seizure localization, or outcome (Engel classification). There was a statistically significant difference at the point in time at which these techniques were used: Group A represented more patients earlier in the series than Group B (p < 0.05). The complication rate attributable to the grids and depth electrodes was 0% in each group. It was more likely that the depth electrodes were placed through the grid if there was a prior resection and the patient was undergoing a new evaluation (p < 0.05). Furthermore, Group A procedures took significantly longer than Group B procedures. Conclusions In this patient series, there was no difference in efficacy of monitoring, complications, or outcome between hippocampal depth electrodes placed laterally through temporal grids or using an occipital bur hole stereotactic approach. Placement of the depth electrodes perpendicularly through the grids and middle temporal gyrus is technically more practical because multiple head positions and redraping are unnecessary, resulting in shorter operative times with comparable results.
Comonitoring of adenosine and dopamine using the Wireless Instantaneous Neurotransmitter Concentration System: proof of principle
Chang, Su-Youne , Tye, Susannah J. , Kimble, Christopher J., Bennet, Kevin E. , Blaha, Charles D. , Lee, Kendall H. , Shon, Young‐Min , Tye, Susannah J , Blaha, Charles

Journal of Neurosurgery | September 4, 2009 | Volume: 112 | Issue: 3 | Pages: 539-548

10.3171/2009.7.jns09787 Get It

Object The authors of previous studies have demonstrated that local adenosine efflux may contribute to the therapeutic mechanism of action of thalamic deep brain stimulation (DBS) for essential tremor. Real-time monitoring of the neurochemical output of DBS-targeted regions may thus advance functional neurosurgical procedures by identifying candidate neurotransmitters and neuromodulators involved in the physiological effects of DBS. This would in turn permit the development of a method of chemically guided placement of DBS electrodes in vivo. Designed in compliance with FDA-recognized standards for medical electrical device safety, the authors report on the utility of the Wireless Instantaneous Neurotransmitter Concentration System (WINCS) for real-time comonitoring of electrical stimulation–evoked adenosine and dopamine efflux in vivo, utilizing fast-scan cyclic voltammetry (FSCV) at a polyacrylonitrile-based (T-650) carbon fiber microelectrode (CFM). Methods The WINCS was used for FSCV, which consisted of a triangle wave scanned between −0.4 and +1.5 V at a rate of 400 V/second and applied at 10 Hz. All voltages applied to the CFM were with respect to an Ag/AgCl reference electrode. The CFM was constructed by aspirating a single T-650 carbon fiber (r = 2.5 μm) into a glass capillary and pulling to a microscopic tip using a pipette puller. The exposed carbon fiber (the sensing region) extended beyond the glass insulation by ~ 50 μm. Proof of principle tests included in vitro measurements of adenosine and dopamine, as well as in vivo measurements in urethane-anesthetized rats by monitoring adenosine and dopamine efflux in the dorsomedial caudate putamen evoked by high-frequency electrical stimulation of the ventral tegmental area and substantia nigra. Results The WINCS provided reliable, high-fidelity measurements of adenosine efflux. Peak oxidative currents appeared at +1.5 V and at +1.0 V for adenosine, separate from the peak oxidative current at +0.6 V for dopamine. The WINCS detected subsecond adenosine and dopamine efflux in the caudate putamen at an implanted CFM during high-frequency stimulation of the ventral tegmental area and substantia nigra. Both in vitro and in vivo testing demonstrated that WINCS can detect adenosine in the presence of other easily oxidizable neurochemicals such as dopamine comparable to the detection abilities of a conventional hardwired electrochemical system for FSCV. Conclusions Altogether, these results demonstrate that WINCS is well suited for wireless monitoring of high-frequency stimulation-evoked changes in brain extracellular concentrations of adenosine. Clinical applications of selective adenosine measurements may prove important to the future development of DBS technology.
Wireless Instantaneous Neurotransmitter Concentration System–based amperometric detection of dopamine, adenosine, and glutamate for intraoperative neurochemical monitoring
Agnesi, Filippo , Tye, Susannah J. , Bledsoe, Jonathan M., Griessenauer, Christoph J. , Kimble, Christopher J., Sieck, Gary C. , Bennet, Kevin E. , Garris, Paul A. , Blaha, Charles D. , Lee, Kendall H. , Sieck, Gary , Tye, Susannah J , Griessenauer, Christoph J , Blaha, Charles

Journal of Neurosurgery | May 8, 2009 | Volume: 111 | Issue: 4 | Pages: 701-711

10.3171/2009.3.jns0990 Get It

Object In a companion study, the authors describe the development of a new instrument named the Wireless Instantaneous Neurotransmitter Concentration System (WINCS), which couples digital telemetry with fast-scan cyclic voltammetry (FSCV) to measure extracellular concentrations of dopamine. In the present study, the authors describe the extended capability of the WINCS to use fixed potential amperometry (FPA) to measure extracellular concentrations of dopamine, as well as glutamate and adenosine. Compared with other electrochemical techniques such as FSCV or high-speed chronoamperometry, FPA offers superior temporal resolution and, in combination with enzyme-linked biosensors, the potential to monitor nonelectroactive analytes in real time. Methods The WINCS design incorporated a transimpedance amplifier with associated analog circuitry for FPA; a microprocessor; a Bluetooth transceiver; and a single, battery-powered, multilayer, printed circuit board. The WINCS was tested with 3 distinct recording electrodes: 1) a carbon-fiber microelectrode (CFM) to measure dopamine; 2) a glutamate oxidase enzyme–linked electrode to measure glutamate; and 3) a multiple enzyme–linked electrode (adenosine deaminase, nucleoside phosphorylase, and xanthine oxidase) to measure adenosine. Proof-of-principle analyses included noise assessments and in vitro and in vivo measurements that were compared with similar analyses by using a commercial hardwired electrochemical system (EA161 Picostat, eDAQ; Pty Ltd). In urethane-anesthetized rats, dopamine release was monitored in the striatum following deep brain stimulation (DBS) of ascending dopaminergic fibers in the medial forebrain bundle (MFB). In separate rat experiments, DBS-evoked adenosine release was monitored in the ventrolateral thalamus. To test the WINCS in an operating room setting resembling human neurosurgery, cortical glutamate release in response to motor cortex stimulation (MCS) was monitored using a large-mammal animal model, the pig. Results The WINCS, which is designed in compliance with FDA-recognized consensus standards for medical electrical device safety, successfully measured dopamine, glutamate, and adenosine, both in vitro and in vivo. The WINCS detected striatal dopamine release at the implanted CFM during DBS of the MFB. The DBS-evoked adenosine release in the rat thalamus and MCS-evoked glutamate release in the pig cortex were also successfully measured. Overall, in vitro and in vivo testing demonstrated signals comparable to a commercial hardwired electrochemical system for FPA. Conclusions By incorporating FPA, the chemical repertoire of WINCS-measurable neurotransmitters is expanded to include glutamate and other nonelectroactive species for which the evolving field of enzyme-linked biosensors exists. Because many neurotransmitters are not electrochemically active, FPA in combination with enzyme-linked microelectrodes represents a powerful intraoperative tool for rapid and selective neurochemical sampling in important anatomical targets during functional neurosurgery.
Development of the Wireless Instantaneous Neurotransmitter Concentration System for intraoperative neurochemical monitoring using fast-scan cyclic voltammetry
Bledsoe, Jonathan M., Kimble, Christopher J., Covey, Daniel P., Blaha, Charles D. , Agnesi, Filippo , Mohseni, Pedram , Whitlock, Sidney V., Johnson, David , Horne, April E., Bennet, Kevin E. , Lee, Kendall H. , Garris, Paul A. , Covey, Dan P. , Blaha, Charles

Journal of Neurosurgery | May 8, 2009 | Volume: 111 | Issue: 4 | Pages: 712-723

10.3171/2009.3.jns081348 Get It

Object Emerging evidence supports the hypothesis that modulation of specific central neuronal systems contributes to the clinical efficacy of deep brain stimulation (DBS) and motor cortex stimulation (MCS). Real-time monitoring of the neurochemical output of targeted regions may therefore advance functional neurosurgery by, among other goals, providing a strategy for investigation of mechanisms, identification of new candidate neurotransmitters, and chemically guided placement of the stimulating electrode. The authors report the development of a device called the Wireless Instantaneous Neurotransmitter Concentration System (WINCS) for intraoperative neurochemical monitoring during functional neurosurgery. This device supports fast-scan cyclic voltammetry (FSCV) at a carbon-fiber microelectrode (CFM) for real-time, spatially and chemically resolved neurotransmitter measurements in the brain. Methods The FSCV study consisted of a triangle wave scanned between −0.4 and 1 V at a rate of 300 V/second and applied at 10 Hz. All voltages were compared with an Ag/AgCl reference electrode. The CFM was constructed by aspirating a single carbon fiber (r = 2.5 μm) into a glass capillary and pulling the capillary to a microscopic tip by using a pipette puller. The exposed carbon fiber (that is, the sensing region) extended beyond the glass insulation by ~ 100 μm. The neurotransmitter dopamine was selected as the analyte for most trials. Proof-of-principle tests included in vitro flow injection and noise analysis, and in vivo measurements in urethane-anesthetized rats by monitoring dopamine release in the striatum following high-frequency electrical stimulation of the medial forebrain bundle. Direct comparisons were made to a conventional hardwired system. Results The WINCS, designed in compliance with FDA-recognized consensus standards for medical electrical device safety, consisted of 4 modules: 1) front-end analog circuit for FSCV (that is, current-to-voltage transducer); 2) Bluetooth transceiver; 3) microprocessor; and 4) direct-current battery. A Windows-XP laptop computer running custom software and equipped with a Universal Serial Bus–connected Bluetooth transceiver served as the base station. Computer software directed wireless data acquisition at 100 kilosamples/second and remote control of FSCV operation and adjustable waveform parameters. The WINCS provided reliable, high-fidelity measurements of dopamine and other neurochemicals such as serotonin, norepinephrine, and ascorbic acid by using FSCV at CFM and by flow injection analysis. In rats, the WINCS detected subsecond striatal dopamine release at the implanted sensor during high-frequency stimulation of ascending dopaminergic fibers. Overall, in vitro and in vivo testing demonstrated comparable signals to a conventional hardwired electrochemical system for FSCV. Importantly, the WINCS reduced susceptibility to electromagnetic noise typically found in an operating room setting. Conclusions Taken together, these results demonstrate that the WINCS is well suited for intraoperative neurochemical monitoring. It is anticipated that neurotransmitter measurements at an implanted chemical sensor will prove useful for advancing functional neurosurgery.