AbstractBackgroundLeadless cardiac pacing (LCP) has emerged as a new modality for permanent pacing. We sought to describe comparative outcomes between LCP and transvenous pacemakers.MethodsPatients receiving LCP (Micra [Medtronic, Minneapolis, MN, USA] and Nanostim [St. Jude Medical/Abbott Laboratories, Chicago, IL, USA]) between 2014 and 2017 at the Mayo Clinic Heart Rhythm Enterprise practice (Rochester, MN, USA; Jacksonville, FL, USA; and Scottsdale, AZ, USA) were identified. We identified 1:1 age‐ and sex‐matched controls receiving single‐chamber transvenous ventricular pacemakers (TVP). Statistical analyses were performed with JMP 13.0.0 (SAS, Institute Cary, NC, USA).ResultsNinety patients underwent LCP implantation (73 Micra and 17 Nanostim) with a median follow‐up duration of 62 (interquartile range 28‐169) days. Both groups had 100% successful device implant rates. There were no differences in procedure‐related major (0% vs 1%) or minor complications (8% vs 3%) in the LCP versus TVP groups (P > 0.05). Excluding Nanostim patients, there was a lower rate of device‐related revision or extraction in the Micra versus TVP groups (0% vs 5%, P = 0.028). Device endocarditis was more common in the TVP group (0% vs 3%, P = 0.04). Estimated longevity was greater for the LCP group (median 12.0 vs 10.0 years, P < 0.0001). An increase in severity of tricuspid valve regurgitation (TR) by ≥2 grades occurred in none of the LCP patients, and in 19% of the TVP patients (P = 0.017).ConclusionThere are no significant differences in procedural complications among patients receiving LCP versus TVP. The Micra group had lower rates of device‐related revision/extraction compared to the TVP group. Patients with leadless pacemaker were less likely to develop endocarditis or worsening TR.
Single-site ventricular pacing via the coronary sinus in patients with tricuspid valve disease
Background: Recognition of rates and causes of hard, patient-centered outcomes of death and cerebrovascular events (CVEs) after heart rhythm disorder management (HRDM) procedures is an essential step for the development of quality improvement programs in electrophysiology laboratories. Our primary aim was to assess and characterize death and CVEs (stroke or transient ischemic attack) after HRDM procedures over a 17-year period. Methods: We performed a retrospective cohort study of all patients undergoing HRDM procedures between January 2000 and November 2016 at the Mayo Clinic. Patients from all 3 tertiary academic centers (Rochester, Phoenix, and Jacksonville) were included in the study. All in-hospital deaths and CVEs after HRDM procedures were identified and were further characterized as directly or indirectly related to the HRDM procedure. Subgroup analysis of death and CVE rates was performed for ablation, device implantation, electrophysiology study, lead extraction, and defibrillation threshold testing procedures. Results: A total of 48 913 patients (age, 65.7±6.6 years; 64% male) who underwent a total of 62 065 HRDM procedures were included in the study. The overall mortality and CVE rates in the cohort were 0.36% (95% confidence interval [CI], 0.31–0.42) and 0.12% (95% CI, 0.09–0.16), respectively. Patients undergoing lead extraction had the highest overall mortality rate at 1.9% (95% CI, 1.34–2.61) and CVE rate at 0.62% (95% CI, 0.32–1.07). Among patients undergoing HRDM procedures, 48% of deaths directly related to the HDRM procedure were among patients undergoing device implantation procedures. Overall, cardiac tamponade was the most frequent direct cause of death (40%), and infection was the most common indirect cause of death (29%). The overall 30-day mortality rate was 0.76%, with the highest being in lead extraction procedures (3.08%), followed by device implantation procedures (0.94%). Conclusions: Half of the deaths directly related to an HRDM procedure were among the patients undergoing device implantation procedures, with cardiac tamponade being the most common cause of death. This highlights the importance of the development of protocols for the quick identification and management of cardiac tamponade even in procedures typically believed to be lower risk such as device implantation.
Electrograms and Marker Delay: Is There a Problem?
BackgroundAlthough sudden death (SD) is a rare complication after atrioventricular junction (AVJ) ablation and permanent pacemaker implantation, the risk factors leading to this SD remain unknown. The purpose of this study was to investigate SD and its risk factors after ablate‐and‐pace strategy for rate control in atrial fibrillation (AF) patients during long‐term follow‐up.HypothesisMethodsFrom January 2005 to December 2009, we enrolled into this study 517 AF patients with AVJ ablation and right ventricular pacemaker implantation. Patients were divided into 2 groups, SD and non‐SD. Cox proportional hazards models were used to assess potential risk factors for overall mortality and SD.ResultsDuring a mean follow‐up of 25.8 ± 18.6 months (range, 3 days to 63.8 months), 53 patients died (15 with SD). Cox proportional hazards models showed that the presence of congestive heart failure, New York Heart Association functional class, chronic renal failure, and nonsustained ventricular tachycardia were risk factors that predicted overall mortality. For SD, the presence of dilated cardiomyopathy and mitral stenosis were associated risk factors. SD was exclusively seen in patients who had narrow QRS complex or right bundle branch block prior to AVJ ablation and pacemaker implantation; SD was not seen in any patient with preexisting complete left bundle branch block.ConclusionsDilated cardiomyopathy, mitral stenosis, and baseline QRS morphology should be examined as potential risk factors for SD after AVJ ablation and pacemaker implantation.
Recent Developments in the Ablation of Ventricular Arrhythmias
Background and Study Aims. The presence of an implantable electromechanical cardiac device (IED) has long been considered a relative contraindication to the performance of video capsule endoscopy (CE). The primary aim of this study was to evaluate the safety of CE in patients with IEDs. A secondary purpose was to determine whether IEDs have any impact on images captured by CE.Patients and Methods.A retrospective chart review of all patients who had a capsule endoscopy at Mayo Clinic in Scottsdale, AZ, USA, or Rochester, MN, USA, (January 2002 to June 2010) was performed to identify CE studies done on patients with IEDs. One hundred and eighteen capsule studies performed in 108 patients with IEDs were identified and reviewed for demographic data, method of preparation, and study data.Results.The most common indications for CE were obscure gastrointestinal bleeding (77%), anemia (14%), abdominal pain (5%), celiac disease (2%), diarrhea (1%), and Crohn’s disease (1%). Postprocedure assessments did not reveal any detectable alteration on the function of the IED. One patient with an ICD had a 25-minute loss of capsule imaging due to recorder defect. Two patients with LVADs had interference with capsule image acquisition.Conclusions.CE did not interfere with IED function, including PM, ICD, and/or LVAD and thus appears safe. Additionally, PM and ICD do not appear to interfere with image acquisition but LVAD may interfere with capsule images and require that capsule leads be positioned as far away as possible from the IED to assure reliable image acquisition.
Mechanisms and Utility of Discrete Great Arterial Potentials in the Ablation of Outflow Tract Ventricular Arrhythmias
Background— Outflow tract ventricular tachycardia originating above the semilunar valves has been reported in a small number of studies. Discrete potentials in the great arteries (above the semilunar valves) have been rarely described in patients undergoing electrophysiology evaluation and radiofrequency ablation for ventricular arrhythmias. The mechanisms of these discrete potentials in the great arteries and the utility of such potentials in guiding radiofrequency ablation are unknown. Methods and Results— Twelve patients with outflow tract ventricular arrhythmia originating above the semilunar valves with discrete arterial potentials were studied. The clinical characteristics, properties of the arterial potentials, electrophysiological evaluation and ablation, and short- and long-term outcomes were reviewed. Of the twelve patients, 8 (67%) were women. The patients’ average age was 41�14 years. The average ejection fraction was 0.52�0.16 (range: 0.16 to 0.75). Contact mapping in the great artery demonstrated discrete near-field electrograms that were separate from far-field ventricular electrograms in all patients (8 above the pulmonary valve and in 4 the aortic valve). One or more of the following electrophysiological characteristics, supportive of an arrhythmogenic substrate, were observed in 10 of 12 patients: (1) A fixed or reproducibly variable pattern of discrete potential–ventricular arrhythmia relationship was present at baseline or during pacing; (2) the discrete potential–ventricular electrogram relationship during sinus rhythm was the reverse of that during the ventricular arrhythmia; (3) during sustained ventricular tachycardia, spontaneous variation of the ventricular (V-V) cycle length was preceded by a similar variation of arterial spike potential–spike potential cycle length; and (4) ablation guided by the discrete arterial potential successfully eliminated the clinical arrhythmia. Ablation was successful in these patients. In the remaining 2 patients, the potentials were believed to be bystanders. Over 10�4 months (range: 5 to 32 months) of follow-up, there have been no recurrences of the premature ventricular complex or ventricular arrhythmia. Conclusions— Discrete potentials are present in the great arteries of a select group of patients with outflow tract ventricular tachycardia originating above the semilunar valves. When an arrhythmogenic relationship can be demonstrated, discrete potentials are useful in guiding ablation within the great vessels, despite significant anatomic complexity.