Background: The purpose of this study is to determine the effects of proximal hamate transfer for proximal pole scaphoid reconstruction upon carpal kinematics. Methods: Eight fresh-frozen cadaveric wrists underwent evaluation of their radiocarpal and midcarpal motion after proximal hamate osteotomy. A wrist simulator was used to apply cyclical tension to the flexor carpi ulnaris (FCU), flexor carpi radialis (FCR), extensor carpi ulnaris (ECU), and extensor carpi radialis longus and brevis stitched together (ECR). Kinematic motion was captured using Moiré Phase Tracking 3-dimensional motion-tracking sensors (MPT, Metria Innovation, Inc, Milwaukee, Wisconsin) to evaluate the lunocapitate and scapholunate angles for each condition. Results: During wrist flexion-extension and radial-ulnar deviation, there were no statistically significant differences about the lunocapitate or scapholunate axis between the intact and post-hamate osteotomy conditions. Conclusions: The harvest of the proximal hamate for proximal pole scaphoid reconstruction does not appear to adversely affect wrist kinematics.
Novel engineered tendon-fibrocartilage-bone composite with cyclic tension for rotator cuff repair
Biomechanical Comparison of Anatomic and Extra-Anatomic Reconstruction Techniques Using Local Grafts for Chronic Instability of the Acromioclavicular Joint
Background: Anatomic reconstruction techniques are increasingly used to address cases of acromioclavicular (AC) joint chronic instability. These usually involve an additional surgical site for autograft harvesting or an allograft. Purpose: To describe a triple-bundle (TB) anatomic reconstruction using on-site autografts, the semiconjoint tendon (SCT) and the coracoacromial ligament (CAL), and compare its primary stability to the native AC joint ligamentous complex and to a modified Weaver-Dunn (WD) reconstruction. Study Design: Controlled laboratory study. Methods: Intact AC joints of 12 paired cadaveric shoulders were tested for anterior, posterior, and superior translations under cyclic loading with a servo-hydraulic testing system. One shoulder from each pair was randomly assigned to the TB group, where 2 SCT strips were used to reconstruct the coracoclavicular ligaments while the distal end of the CAL was transferred to the distal extremity of the clavicle to reconstruct the AC ligaments; the other shoulder received a modified WD reconstruction. After reconstruction, the same translational testing was performed, with an additional load-to-failure test in the superior direction. Results: In both the TB and the WD groups, no significant differences were found before and after reconstruction in terms of joint displacements after cyclic loading, in all 3 directions. Compared with the WD reconstruction, the TB repair resulted in significantly lower displacements in both the anterior (ie, 2.59 ± 1.08 mm, P = .011) and posterior (ie, 10.17 ± 6.24 mm, P = .014) directions, but not in the superior direction. No significant differences were observed between the 2 reconstructions during the load-to-failure testing, except for the displacement to failure, which was significantly smaller (ie, 5.34 ± 2.97 mm) in the WD group ( P = .037). Conclusion: Anterior, posterior, and superior displacements after an anatomic reconstruction of the AC joint complex using the SCT and CAL as graft material were similar to those of native AC joints and significantly smaller in the axial plane than those of AC joints after a WD repair. Clinical Relevance: An anatomic reconstruction is achievable using the CAL and the SCT as on-site graft materials, providing satisfactory initial stability and thereby allowing earlier mobilization.
Comparison of Autograft and Allograft with Surface Modification for Flexor Tendon Reconstruction
Background: Flexor tendon injury is common, and tendon reconstruction is indicated clinically if the primary repair fails or cannot be performed immediately after tendon injury. The purpose of the current study was to compare clinically standard extrasynovial autologous graft (EAG) tendon and intrasynovial allogeneic graft (IAG) that had both undergone biolubricant surface modification in a canine in vivo model. Methods: Twenty-four flexor digitorum profundus (FDP) tendons from the second and fifth digits of 12 dogs were used for this study. In the first phase, a model of failed FDP tendon repair was created. After 6 weeks, the ruptured FDP tendons with a scarred digit were reconstructed with the use of either EAG or IAG tendons treated with carbodiimide-derivatized hyaluronic acid and lubricin. At 12 weeks after tendon reconstruction, the digits were harvested for functional, biomechanical, and histologic evaluations. Results: The tendon failure model was a clinically relevant and reproducible model for tendon reconstruction. The IAG group demonstrated improved digit function with decreased adhesion formation, lower digit work of flexion, and improved graft gliding ability compared with the EAG group. However, the IAG group had decreased healing at the distal tendon-bone junction. Our histologic findings verified the biomechanical evaluations and, further, showed that cellular repopulation of allograft at 12 weeks after reconstruction is still challenging. Conclusions: FDP tendon reconstruction using IAG with surface modification has some beneficial effects for reducing adhesions but demonstrated inferior healing at the distal tendon-bone junction compared with EAG. These mixed results indicate that vitalization and turnover acceleration are crucial to reducing failure of reconstruction with allograft. Clinical Relevance: Flexor tendon reconstruction is a common surgical procedure. However, postoperative adhesion formation may lead to unsatisfactory clinical outcomes. In this study, we developed a potential flexor tendon allograft using chemical and tissue-engineering approaches. This technology could improve function following tendon reconstruction.
A 3D finite element model of prophylactic vertebroplasty in the metastatic spine: Vertebral stability and stress distribution on adjacent vertebrae
ABSTRACTIntroduction: The aim of this study was to assess alterations in median nerve (MN) biomechanics within the carpal tunnel resulting from ultrasound‐guided hydrodissection in a cadaveric model. Methods: Twelve fresh frozen human cadaver hands were used. MN gliding resistance was measured at baseline and posthydrodissection, by pulling the nerve proximally and then returning it to the origin. Six specimens were treated with hydrodissection, and 6 were used as controls. Results: In the hydrodissection group there was a significant reduction in mean peak gliding resistance of 92.9 ± 34.8 mN between baseline and immediately posthydrodissection (21.4% ± 10.5%; P = 0.001). No significant reduction between baseline and the second cycle occurred in the control group: 9.6 ± 29.8 mN (0.4% ± 5.3%; P = 0.467). Discussion: Hydrodissection can decrease the gliding resistance of the MN within the carpal tunnel, at least in wrists unaffected by carpal tunnel syndrome. A clinical trial of hydrodissection seems justified. Muscle Nerve 57: 25–32, 2018
Interpreting oblique impact data from an accelerometer-instrumented ice hockey helmet
Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology | April 7, 2017 | Volume: 231 | Issue: 4 | Pages: 307-316
The purpose of this study was to assess the correlations of acceleration measurements between an instrumented hockey helmet and the Hybrid III headform and to determine whether collision with a broad surface affects the correlations between these data. A CCM Vector hockey helmet, instrumented with the Head Impact Telemetry System, was fitted onto an instrumented Hybrid III headform and dropped onto an inclined plate to simulate impacts in hockey. The helmet and headform were dropped from 0.15, 0.30, and 0.60 m at different orientations to create impacts to the vertex, occipital, right, left, and forehead surfaces. Peak linear and rotational acceleration magnitudes and head injury criteria were assessed for each system. Correlations were assessed with the Pearson correlation coefficient, and linear regression models were generated. Relative error was assessed, and results were compared with the Wilcoxon signed rank test. Peak acceleration magnitudes generally had strong mathematical correlations, although a 1:1 linear relationship for rotational acceleration data was not observed. Differences between helmet and head peak acceleration magnitudes were significant. The linear relationship varied according to the impact direction. Instrumented helmet and head data demonstrated a strong mathematical correlation, but measures of linear acceleration generally had better 1:1 agreement than rotational acceleration measures. There is some dependence in the relationship between the helmet and head data on the impact direction, with vertex strikes showing the weakest correlation. Although data generated from the helmet may be useful for interpreting head accelerations experienced by on-ice players, additional analysis of the time-series data should be performed to understand its full utility.