Citations 9

Biomechanical Simulation of Rotator Cuff Tear and Glenohumeral Stability
Hsu, Horng Chaung, Luo, Zong-Ping, An, Kai , Luo, Zong-Ping, O’Driscoll, Shawn W.

Advances in Bioengineering | October 7, 2025 | Volume: No volume available | Issue: No issue available | Pages: 145-146

10.1115/imece1995-0138 Get It

Abstract This study examined in vitro glenohumeral instability under two simulated biomechanical models of rotator cuff tear: 1) tendon-defect model and 2) muscle-unloaded model. The results indicated that rotator cuff tear significantly increased the joint instability. Significant difference also existed between the two tested models. The tendon-defect model underestimated the joint instability in most simulated shoulder positions.
Loading Environment of the Supraspinatus Musculotendinous Unit
Luo, Zong-Ping, Hsu, Horng Chaung, Morrey, B.F. , An, Kai , Luo, Zong-Ping

Advances in Bioengineering | October 7, 2025 | Volume: No volume available | Issue: No issue available | Pages: 147-148

10.1115/imece1995-0139 Get It

Abstract The stress environment of the extracellular matrix of the supraspinatus tendon, including the stress distribution and concentration, was evaluated by using a finite element model. Stress riser was found around the insertion at the articular side of the tendon. Compressive and shear stresses were observed at the articular side which corresponded to the region associated with fibrocartilaginous matrix. This area corresponded well with the critical zone of potential tear observed clinically.
Determination of Inhomogeneous and Anisotropic Material Properties of Biomembranes
Luo, Zong-Ping, Grabowski, John, An, Kai , Luo, Zong-Ping, Grabowski, John J.

Advances in Bioengineering | October 7, 2025 | Volume: No volume available | Issue: No issue available | Pages: 287-288

10.1115/imece1995-0209 Get It

Abstract A methodology was developed for potential determination of the material properties of inhomogeneous and anisotropic biomembranes. Mathematical estimations and computer simulations were performed to determine the effect of load and displacement errors on the property values. The results indicated that the material properties were particularly sensitive to displacement errors. The determination of non-dominant components requires more accurate experimental measurements.
Prediction of Effects of Mechanical Stress and Estrogen on Bony Structure Using Fuzzy Logic Control
Luo, Zong-Ping, An, Kai , Turner, Russell T. , Luo, Zong-Ping

Advances in Bioengineering | January 31, 2022 | Volume: No volume available | Issue: No issue available | Pages: 345-346

10.1115/imece1998-0166 Get It

Abstract A theoretical model has been developed based on fuzzy logic control to predict bony response to mechanical load and estrogen. The results show good agreement with the experimental findings, which suggests that bone may be regulated by simple remodeling rules, similar to those used in the fuzzy logic control.
Development and Calibration of a Nanometer Manipulation and Measurement System for Molecular Biomechanical Testing
Luo, Zong-Ping, An, Kai , Luo, Zong-Ping

Advances in Bioengineering | January 31, 2022 | Volume: No volume available | Issue: No issue available | Pages: 221-222

10.1115/imece1998-0110 Get It

Abstract An optical tweezers system has been adopted for molecular biomechanical testing. To achieve nanometer manipulation and measurement, the system was modified with a piezo-stage and an interferometer. A systematic calibration was then performed on the displacement resolution. The results revealed that the system has a nanometer resolution which is sufficient for the measurement of deformation and stiffness of single macro-molecules.
In Vitro Measurement of Center of Pressure Changes of Selected Muscles Acting About the Ankle Joint Under Weight-Bearing
Kim, Kyu Jung, Kitaoka, Harold B. , Uchiyama, Eiichi, An, Kai , Kaufman, Kenton R.

Advances in Bioengineering | January 31, 2022 | Volume: No volume available | Issue: No issue available | Pages: 383-384

10.1115/imece1998-0185 Get It

Abstract Electromyography (EMG) measurement has been the one of the major sources of information to understand the neuromuscular control of human locomotion, while a limited amount of knowledge is available due to its complicate signal structure. Other measurable parameters may be of little value in extracting the neuromuscular information without having a precise mechanical relationship.
A Method to Determine the Effect of the Individual Rotator Cuff Muscles to Dynamic Joint Stability of the Shoulder
Kim, Kyu Jung, Lee, Seok Beom, An, Kai , Morrey, B.F.

Advances in Bioengineering | January 31, 2022 | Volume: No volume available | Issue: No issue available | Pages: 385-386

10.1115/imece1998-0186 Get It

Abstract The prevalence of rotator cuff disease among the elderly population and the greatest incidence of acute dislocations will continue to provide challenging patient management decisions. Stability of the shoulder is critical to successful upper extremity function. The GH joint is stabilized by passive capsuloligamentous restraints as well as by active dynamic stabilizers through concavity compression. The compression of the convex humeral head (HH) into the concave glenoid fossa (GF) counteracts against translational shear forces (Matsen et. al 1994). The major compressive load across the joint is provided by the action of the surrounding musculature, especially the rotator cuff. The muscles may generate both compressive and shear force components as well as moments. The purpose of this study is to describe a new testing methodology of how to estimate the contribution of individual rotator cuff muscles to the dynamic stability of the GH joint at a given joint position.
Interpreting oblique impact data from an accelerometer-instrumented ice hockey helmet
Jorgensen, Janelle, Thoreson, Andrew R. , Stuart, Michael, Loyd, Andre M., Smith, Aynsley M., Twardowski, Casey P., Gaz, Daniel V., Hollman, John H. , An, Kai , Krause, David A. , An, Kai Nan, Stuart, Michael J. , Hollman, John

Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology | April 7, 2017 | Volume: 231 | Issue: 4 | Pages: 307-316

10.1177/1754337117700549 Get It

The purpose of this study was to assess the correlations of acceleration measurements between an instrumented hockey helmet and the Hybrid III headform and to determine whether collision with a broad surface affects the correlations between these data. A CCM Vector hockey helmet, instrumented with the Head Impact Telemetry System, was fitted onto an instrumented Hybrid III headform and dropped onto an inclined plate to simulate impacts in hockey. The helmet and headform were dropped from 0.15, 0.30, and 0.60 m at different orientations to create impacts to the vertex, occipital, right, left, and forehead surfaces. Peak linear and rotational acceleration magnitudes and head injury criteria were assessed for each system. Correlations were assessed with the Pearson correlation coefficient, and linear regression models were generated. Relative error was assessed, and results were compared with the Wilcoxon signed rank test. Peak acceleration magnitudes generally had strong mathematical correlations, although a 1:1 linear relationship for rotational acceleration data was not observed. Differences between helmet and head peak acceleration magnitudes were significant. The linear relationship varied according to the impact direction. Instrumented helmet and head data demonstrated a strong mathematical correlation, but measures of linear acceleration generally had better 1:1 agreement than rotational acceleration measures. There is some dependence in the relationship between the helmet and head data on the impact direction, with vertex strikes showing the weakest correlation. Although data generated from the helmet may be useful for interpreting head accelerations experienced by on-ice players, additional analysis of the time-series data should be performed to understand its full utility.
The relationship of vascularity and water content to tensile strength in a patellar tendon replacement of the anterior cruciate in dogs
McFarland, Edward G. , Morrey, B.F. , An, Kai , Wood, Michael B.

The American Journal of Sports Medicine | June 21, 2007 | Volume: 14 | Issue: 6 | Pages: 436-448

10.1177/036354658601400602 Get It

The methods and materials for ACL reconstruction are important issues for the practicing orthopaedic sur geon. In this study a model was developed to study the biological and biomechanical characteristics of a patel lar tendon autograft used for ACL reconstruction. Spe cifically it was hypothesized that since vascularity of these grafts reflects their "healthiness," strength and vascularity should be inversely related in the early pe riod after implantation. Using an over the top technique, a patellar tendon graft was placed in three groups of dogs and studied at 37, 57, and 120 days. Vascularity of the grafts was measured using technetium-tagged red blood cells, and percent water by weight was determined by dessication. Tensile testing to failure was performed using an MTS machine. The grafts became more vascular, more hydrated, less stiff, and less strong (by 4 weeks) than controls. By 16 weeks the vascular response was subsiding but the grafts remained only 40% as strong as controls. Percent water increased significantly over controls for all time periods. Decrease in strength correlated poorly with vascularity but correlated well with increase in percent water. These findings suggest that the change in strength of an intraarticular ACL replacement relates more to a basic rearrangement of its collagen-ground substance relationships, and that vascularity may re flect the inflammatory response bringing about these changes. The model developed in this study serves as a basis for further studies, and the findings reveal important information about the behavior of ACL graft ing materials.