Abstract Aims Limited US outcome data exist among patients with myocardial injury and types 1 and 2 myocardial infarction (MI) evaluated with high-sensitivity cardiac troponin (hs-cTn). Methods and results This is an observational US cohort study of emergency department (ED) patients undergoing hs-cTnT measurement. Cases with ≥1 hs-cTnT increase >99th percentile were adjudicated following the Fourth Universal Definition of MI. Post-discharge major adverse cardiovascular events (MACE) included death, MI, heart failure (HF) hospitalization, stroke or transient ischaemic attack, and new-onset atrial fibrillation or flutter during 2 years follow-up. Among 2002 patients, 857 (43%) had ≥1 hs-cTnT >99th percentile. Among these, 702 (81.9%) had myocardial injury, 64 (7.5%) had type 1 MI, and 91 (10.6%) had type 2 MI. Compared with patients without myocardial injury, type 2 MI [8.4 vs. 50%; adjusted hazard ratio (HR) 2.31, 95% confidence interval (CI) 1.49–3.58] and myocardial injury (8.4 vs. 47%; adjusted HR 3.13, 95% CI 2.39–4.09) had a higher risk of MACE, in large part because of death and HF hospitalizations. Compared with patients with type 1 MI, type 2 MI (23 vs. 50%; adjusted HR 2.24; 95% CI 1.23–4.10) and myocardial injury (23 vs. 47%; adjusted HR 2.02; 95% CI 1.20–3.40) also have a higher risk of MACE. Conclusion Among unselected US ED patients undergoing hs-cTnT measurement, most increases are due to myocardial injury, and type 2 MI is more frequent than type 1 MI. Patients with myocardial injury and type 2 MI have morbid outcomes, in large part due to death and HF.
Rapid Exclusion of Acute Myocardial Injury and Infarction With a Single High-Sensitivity Cardiac Troponin T in the Emergency Department: A Multicenter United States Evaluation
Background: There are good data to support using a single high-sensitivity cardiac troponin T (hs-cTnT) below the limit of detection of 5 ng/L to exclude acute myocardial infarction. Per the US Food and Drug Administration, hs-cTnT can only report to the limit of quantitation of 6 ng/L, a threshold for which there are limited data. Our goal was to determine whether a single hs-cTnT below the limit of quantitation of 6 ng/L is a safe strategy to identify patients at low risk for acute myocardial injury and infarction. Methods: The efficacy (proportion identified as low risk based on baseline hs-cTnT<6 ng/L) of identifying low-risk patients was examined in a multicenter (n=22 sites) US cohort study of emergency department patients undergoing at least 1 hs-cTnT (CV Data Mart Biomarker cohort). We then determined the performance of a single hs-cTnT<6 ng/L (biomarker alone) to exclude acute myocardial injury (subsequent hs-cTnT >99th percentile in those with an initial hs-cTnT<6 ng/L). The clinically intended rule-out strategy combining a nonischemic ECG with a baseline hs-cTnT<6 ng/L was subsequently tested in an adjudicated cohort in which the diagnostic performance for ruling out acute myocardial infarction and safety (myocardial infarction or death at 30 days) were evaluated. Results: A total of 85 610 patients were evaluated in the CV Data Mart Biomarker cohort, among which 24 646 (29%) had a baseline hs-cTnT<6 ng/L. Women were more likely than men to have hs-cTnT<6 ng/L (38% versus 20%, P <0.0001). Among 11 962 patients with baseline hs-cTnT<6 ng/L and serial measurements, only 1.2% developed acute myocardial injury, resulting in a negative predictive value of 98.8% (95% CI, 98.6–99.0) and sensitivity of 99.6% (95% CI, 99.5–99.6). In the adjudicated cohort, a nonischemic ECG with hs-cTnT<6 ng/L identified 33% of patients (610/1849) as low risk and resulted in a negative predictive value and sensitivity of 100% and a 30-day rate of 0.2% for myocardial infarction or death. Conclusions: A single hs-cTnT below the limit of quantitation of 6 ng/L is a safe and rapid method to identify a substantial number of patients at very low risk for acute myocardial injury and infarction.
High-Sensitivity Cardiac Troponin T for the Detection of Myocardial Injury and Risk Stratification in COVID-19
Abstract Background Limited data exist on high-sensitivity cardiac troponin (hs-cTn) for risk-stratification in COVID-19. Methods We conducted a multicenter, retrospective, observational, US-based study of COVID-19 patients undergoing hs-cTnT. Outcomes included short-term mortality (in-hospital and 30-days post-discharge) and a composite of major adverse events, including respiratory failure requiring mechanical ventilation, cardiac arrest, and shock within the index presentation and/or mortality during the index hospitalization or within 30-days post-discharge. Results Among 367 COVID-19 patients undergoing hs-cTnT, myocardial injury was identified in 46%. They had a higher risk for mortality (20% vs 12%, P < 0.0001; unadjusted HR 4.44, 95% CI 2.13–9.25, P < 0.001) and major adverse events (35% vs. 11%, P < 0.0001; unadjusted OR 4.29, 95% CI 2.50–7.40, P < 0.0001). Myocardial injury was associated with major adverse events (adjusted OR 3.84, 95% CI 2.00–7.36, P < 0.0001) but not mortality. Baseline (adjusted OR 1.003, 95% CI 1.00–1.007, P = 0.047) and maximum (adjusted OR 1.005, 95% CI 1.001–1.009, P = 0.0012) hs-cTnT were independent predictors of major adverse events. Most (95%) increases were due to myocardial injury, with 5% (n = 8) classified as type 1 or 2 myocardial infarction. A single hs-cTnT <6 ng/L identified 26% of patients without mortality, with a 94.9% (95% CI 87.5–98.6) negative predictive value and 93.1% sensitivity (95% CI 83.3–98.1) for major adverse events in those presenting to the ED. Conclusions Myocardial injury is frequent and prognostic in COVID-19. While most hs-cTnT increases are modest and due to myocardial injury, they have important prognostic implications. A single hs-cTnT <6 ng/L at presentation may facilitate the identification of patients with a favorable prognosis.
Sex-Specific 99th Percentile URLs for Cardiac Troponin Assays—Their Time Has Come