Abstract Aims Current non-invasive screening methods for cardiac allograft rejection have shown limited discrimination and are yet to be broadly integrated into heart transplant care. Given electrocardiogram (ECG) changes have been reported with severe cardiac allograft rejection, this study aimed to develop a deep-learning model, a form of artificial intelligence, to detect allograft rejection using the 12-lead ECG (AI-ECG). Methods and results Heart transplant recipients were identified across three Mayo Clinic sites between 1998 and 2021. Twelve-lead digital ECG data and endomyocardial biopsy results were extracted from medical records. Allograft rejection was defined as moderate or severe acute cellular rejection (ACR) based on International Society for Heart and Lung Transplantation guidelines. The extracted data (7590 unique ECG-biopsy pairs, belonging to 1427 patients) was partitioned into training (80%), validation (10%), and test sets (10%) such that each patient was included in only one partition. Model performance metrics were based on the test set (n = 140 patients; 758 ECG-biopsy pairs). The AI-ECG detected ACR with an area under the receiver operating curve (AUC) of 0.84 [95% confidence interval (CI): 0.78–0.90] and 95% (19/20; 95% CI: 75–100%) sensitivity. A prospective proof-of-concept screening study (n = 56; 97 ECG-biopsy pairs) showed the AI-ECG detected ACR with AUC = 0.78 (95% CI: 0.61–0.96) and 100% (2/2; 95% CI: 16–100%) sensitivity. Conclusion An AI-ECG model is effective for detection of moderate-to-severe ACR in heart transplant recipients. Our findings could improve transplant care by providing a rapid, non-invasive, and potentially remote screening option for cardiac allograft function.
Screening for cardiac allograft rejection among heart transplant recipients using an electrocardiogram-based deep learning model
Abstract Background Current approaches utilizing non-invasive methods to screen for cardiac allograft rejection (gene expression profiling and cell free DNA) have yet to be broadly integrated into heart transplant management and have shown limited discrimination (AUCs of 0.68 and 0.77, respectively). Changes in the electrocardiogram (ECG) have been reported at the time of severe cardiac rejection, including low voltages and conduction abnormalities. It remains unknown if subtle ECG changes correlating with cardiac allograft rejection can be detected earlier using machine learning methods. Purpose We sought to develop an artificial intelligence (AI) model to detect cardiac allograft rejection based on the 12 lead ECG. Methods We identified all patients who underwent a heart transplant at 3 hospital sites within a single health system from Jan 1998 through Apr 2021 and extracted digital 12-lead ECG data as well as endomyocardial biopsy pathology results from the electronic medical record. We partitioned our data into a training (80%), validation (10%), and test set (10%) based on a group stratification sampling. Each patient was present in only one set and each set had a positivity rate of 2.6% with 6,074/758/758 ECGs belonging to 1,146/140/141 unique patients in each set respectively. Cardiac allograft rejection was defined as moderate or severe acute cellular rejection based on International Society for Heart and Lung Transplantation (ISHLT) guidelines. A convolutional neural network, using the 12-lead ECG data as input, was trained with hyperparameter optimization for regularization, learning rate adjustments, and class weights. Model performance metrics were based on the test data and estimated using the final model architecture. Results 1,587 heart transplant recipients who had at least one endomyocardial biopsy were evaluated for inclusion. We limited our sample to ECGs performed within 30 days of the biopsy date (7,590 ECGs, representing 1,425 unique patients). Our study population had a median age of 55.8 years and 28.7% were female. The median number of ECG-biopsy pairs per patient was 5. The majority of endomyocardial biopsy results were classified as none or mild rejection (97.1%), and 2.9% had moderate/severe rejection. The ECG-based AI model detected cardiac allograft rejection with an area under the receiver operative curve (AUC) of 0.84 in the test set. The sensitivity, specificity, positive and negative predictive values were 95%, 52.6%. 5.2% and 99.7% respectively. Conclusions An AI-ECG model appears to outperform novel non-invasive laboratory tests (gene expression profiling and cell free DNA) for detecting cardiac allograft rejection and does not require a blood draw or the additional complexities surrounding sample processing. This model relies on a readily available and relatively inexpensive test, the ECG. In addition, AI predictions can be made available within a few minutes following ECG acquisition. Funding Acknowledgement Type of funding sources: Private hospital(s). Main funding source(s): Mayo Clinic
MERGING ADVANCE TECHNOLOGY TO IMPROVE OUTCOMES IN HEART TRANSPLANTATION - A CASE REPORT
One of the signicant obstacles to donor heart utilization is that increasingly prolonged cold ischemic times are associated with worsened short- and long-term outcomes. As a result, most transplant centers aim to limit cold ischemic times to less than four hours. The TransMedics Organ Care System (OCS) (Trans Medics, Andover MA) is a portable ex vivo perfusion system designed to store a donor heart in a beating, metabolically active state, until it reaches the recipient, thereby allowing extended time outside the body while minimizing the effects of cold storage. We present a case of a heart transplant recipient supported with the Impella 5.5 as a bridge to transplantation who received a donation after circulatory death (DCD) heart supported by OCS. To our knowledge, this is the rst report of such a case.
REN3: Percutaneous Axillary Temporary Mechanical Support Improves Renal Function Prior To Heart Transplantation In Patients With Chronic Kidney Disease
AbstractIntroductionThe present study aimed to compare the clinical outcomes of heart transplant patients whose donor hearts were preserved with the SherpaPak controlled cold organ system versus the conventional ice storage technique.MethodsAll patients undergoing heart transplantation at our center between January 2019 and April 2021 were divided into two groups according to the technique used during donor heart preservation and transport. The first group consisted of 34 SherpaPak controlled temperature preservation patients, and the second group consisted of 47 patients where the conventional three bags and ice technique was utilized during organ transportation. The two groups were compared based on demographics, operative details, and postoperative outcomes.ResultsThere were no significant differences between the groups regarding Vasoactive Inotropic Score (VIS), Primary Graft Dysfunction (PGD), and the need for a transient pacer. However, the VIS, PGD, and pacing trends were lower in the SherpaPak patients even though the total ischemic and cardiopulmonary bypass times were significantly longer. Furthermore, SherpaPak patients exhibited a shorter stay in the ICU with no severe PGD and mortality.ConclusionThe SherpaPak donor heart preservation provides safe outcomes in heart transplant patients. Further research is needed to utilize this method for longer durations of ischemic time and expand travel distances for organ transportation.
Controlled temperatures in cold preservation provides safe heart transplantation results
Abstract Background Cardiovascular disease (CVD) has been identified as a major threat to maternal health in the US and UK with cardiomyopathy being one of the most common acquired CVD in the pregnant and postpartum period. Diagnosing cardiomyopathy in pregnancy is challenging due to an overlap of cardiovascular symptoms with normal pregnancy symptoms. Purpose The purpose of this study was to evaluate the effectiveness of an ECG based deep learning model in identifying cardiomyopathy among pregnant and postpartum women. Methods We utilized an ECG based deep learning model to detect cardiomyopathy in a cohort of pregnant or postpartum women seen at multiple hospital sites. Model performance was evaluated using area under the curve (AUC), accuracy, sensitivity, and specificity. We compared the diagnostic probabilities of the deep learning model with natriuretic peptides and a multivariable model consisting of demographic and clinical parameters. Results 1,807 women were included. 7%, 10% and 13% had LVEF ≤35%, <45% and <50% respectively. The ECG based deep learning model identified cardiomyopathy with an AUC of 0.92 for left ventricular ejection fraction (LVEF) ≤35%, 0.89 for LVEF <45% and 0.87 for LVEF <50%. For LVEF ≤35%, AUC was higher in Black (0.95) and Hispanic (0.98) women compared to white (0.91). Natriuretic peptides and the multivariable model had AUCs of 0.85 and 0.72 respectively. Conclusions A deep learning model effectively identifies cardiomyopathy in pregnant or postpartum women, outperforms natriuretic peptides and traditional clinical parameters with the potential to become a powerful initial screening tool for cardiomyopathy in the obstetric care setting. Funding Acknowledgement Type of funding sources: Other. Main funding source(s): This study was made possible using resources supported by the Mayo Clinic Women's Health Research Center and the Mayo Clinic Building Interdisciplinary Research Careers in Women's Health (BIRCWH) Program funded by the National Institutes of Health (NIH), grant number K12 HD065987. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.
Detecting cardiomyopathies in pregnancy and the postpartum period using ECG
Abstract Background Cardiovascular disease (CVD) has been identified as a major threat to maternal health in the US and UK with cardiomyopathy being one of the most common acquired CVD in the pregnant and postpartum period. Diagnosing cardiomyopathy in pregnancy is challenging due to an overlap of cardiovascular symptoms with normal pregnancy symptoms. Purpose The purpose of this study was to evaluate the effectiveness of an ECG based deep learning model in identifying cardiomyopathy among pregnant and postpartum women. Methods We utilized an ECG based deep learning model to detect cardiomyopathy in a cohort of pregnant or postpartum women seen at multiple hospital sites. Model performance was evaluated using area under the curve (AUC), accuracy, sensitivity, and specificity. We compared the diagnostic probabilities of the deep learning model with natriuretic peptides and a multivariable model consisting of demographic and clinical parameters. Results 1,807 women were included. 7%, 10% and 13% had LVEF ≤35%, <45% and <50% respectively. The ECG based deep learning model identified cardiomyopathy with an AUC of 0.92 for left ventricular ejection fraction (LVEF) ≤35%, 0.89 for LVEF <45% and 0.87 for LVEF <50%. For LVEF ≤35%, AUC was higher in Black (0.95) and Hispanic (0.98) women compared to white (0.91). Natriuretic peptides and the multivariable model had AUCs of 0.85 and 0.72 respectively. Conclusions A deep learning model effectively identifies cardiomyopathy in pregnant or postpartum women, outperforms natriuretic peptides and traditional clinical parameters with the potential to become a powerful initial screening tool for cardiomyopathy in the obstetric care setting. Funding Acknowledgement Type of funding sources: Other. Main funding source(s): This study was made possible using resources supported by the Mayo Clinic Women's Health Research Center and the Mayo Clinic Building Interdisciplinary Research Careers in Women's Health (BIRCWH) Program funded by the National Institutes of Health (NIH), grant number K12 HD065987. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.
Detecting cardiomyopathies in pregnancy and the postpartum period with an electrocardiogram-based deep learning model
Abstract Aims Cardiovascular disease is a major threat to maternal health, with cardiomyopathy being among the most common acquired cardiovascular diseases during pregnancy and the postpartum period. The aim of our study was to evaluate the effectiveness of an electrocardiogram (ECG)-based deep learning model in identifying cardiomyopathy during pregnancy and the postpartum period. Methods and results We used an ECG-based deep learning model to detect cardiomyopathy in a cohort of women who were pregnant or in the postpartum period seen at Mayo Clinic. Model performance was evaluated using the area under the receiver operating characteristic curve (AUC), accuracy, sensitivity, and specificity. We compared the diagnostic probabilities of the deep learning model with natriuretic peptides and a multivariable model consisting of demographic and clinical parameters. The study cohort included 1807 women; 7%, 10%, and 13% had left ventricular ejection fraction (LVEF) of 35% or less, <45%, and <50%, respectively. The ECG-based deep learning model identified cardiomyopathy with AUCs of 0.92 (LVEF ≤ 35%), 0.89 (LVEF < 45%), and 0.87 (LVEF < 50%). For LVEF of 35% or less, AUC was higher in Black (0.95) and Hispanic (0.98) women compared to White (0.91). Natriuretic peptides and the multivariable model had AUCs of 0.85 to 0.86 and 0.72, respectively. Conclusions An ECG-based deep learning model effectively identifies cardiomyopathy during pregnancy and the postpartum period and outperforms natriuretic peptides and traditional clinical parameters with the potential to become a powerful initial screening tool for cardiomyopathy in the obstetric care setting.
Impella flow pump reinsertion after axillary graft thrombectomy: Technical points in replacing axillary Impella
Axillary Impella devices are increasingly employed for long-term support of patients with systolic heart failure and shock. Axillary access allows for awake support and ambulation, which carries an inherent risk of disconnection or malposition. We report a series of two cases where device replacement due to dysfunction and malposition can be completed safely through the original axillary graft using axillary graft thrombectomy, given that the clot burden could be a major source of morbidity to the patient.