Back to Authors

Dangott, Bryan J

Mayo Clinic

Department of Laboratory Medicine and Pathology, Mayo Clinic, Jacksonville, FL, USA.

Citations 3

Challenges and Opportunities in Cytopathology Artificial Intelligence
VandeHaar, Meredith A. , Alasi, Hussien , Doganay, Fatih, Alazab, Heba, Xiao, Yao , Balan, Jagadheshwar , Dangott, Bryan, Nassar, Aziza , Akkus, Zeynettin , Al-Asi, Hussien , Yilmaz, Ibrahim, Balan, Jagadheshwar , Dangott, Bryan J, Nassar, Aziza , Akkus, Zeynettin , Yilmaz, Ibrahim, Reynolds, Jordan

Bioengineering | February 13, 2025 | Volume: 12 | Issue: 2 | Pages: 176

10.3390/bioengineering12020176 Get It

Artificial Intelligence (AI) has the potential to revolutionize cytopathology by enhancing diagnostic accuracy, efficiency, and accessibility. However, the implementation of AI in this field presents significant challenges and opportunities. This review paper explores the current landscape of AI applications in cytopathology, highlighting the critical challenges, including data quality and availability, algorithm development, integration and standardization, and clinical validation. We discuss challenges such as the limitation of only one optical section and z-stack scanning, the complexities associated with acquiring high-quality labeled data, the intricacies of developing robust and generalizable AI models, and the difficulties in integrating AI tools into existing laboratory workflows. The review also identifies substantial opportunities that AI brings to cytopathology. These include the potential for improved diagnostic accuracy through enhanced detection capabilities and consistent, reproducible results, which can reduce observer variability. AI-driven automation of routine tasks can significantly increase efficiency, allowing cytopathologists to focus on more complex analyses. Furthermore, AI can serve as a valuable educational tool, augmenting the training of cytopathologists and facilitating global health initiatives by making high-quality diagnostics accessible in resource-limited settings. The review underscores the importance of addressing these challenges to harness the full potential of AI in cytopathology, ultimately improving patient care and outcomes.
Artificial Intelligence Advances in Transplant Pathology
Rahman, Md Arafatur , Albadri, Sam , Salem, Fadi , Dangott, Bryan, Nassar, Aziza , Akkus, Zeynettin , Yilmaz, Ibrahim, Albadri, Sam T, Salem, Fadi E , Dangott, Bryan J, Taner, C. Burcin , Nassar, Aziza , Akkus, Zeynettin , Yilmaz, Ibrahim

Bioengineering | September 4, 2023 | Volume: 10 | Issue: 9 | Pages: 1041

10.3390/bioengineering10091041 Get It

Transplant pathology plays a critical role in ensuring that transplanted organs function properly and the immune systems of the recipients do not reject them. To improve outcomes for transplant recipients, accurate diagnosis and timely treatment are essential. Recent advances in artificial intelligence (AI)-empowered digital pathology could help monitor allograft rejection and weaning of immunosuppressive drugs. To explore the role of AI in transplant pathology, we conducted a systematic search of electronic databases from January 2010 to April 2023. The PRISMA checklist was used as a guide for screening article titles, abstracts, and full texts, and we selected articles that met our inclusion criteria. Through this search, we identified 68 articles from multiple databases. After careful screening, only 14 articles were included based on title and abstract. Our review focuses on the AI approaches applied to four transplant organs: heart, lungs, liver, and kidneys. Specifically, we found that several deep learning-based AI models have been developed to analyze digital pathology slides of biopsy specimens from transplant organs. The use of AI models could improve clinicians’ decision-making capabilities and reduce diagnostic variability. In conclusion, our review highlights the advancements and limitations of AI in transplant pathology. We believe that these AI technologies have the potential to significantly improve transplant outcomes and pave the way for future advancements in this field.
Non-invasive detection of cardiac allograft rejection among heart transplant recipients using an electrocardiogram based deep learning model
Adedinsewo, Demilade , Hardway, Heather D , Morales-Lara, Andrea Carolina , Wieczorek, Mikolaj A. , Douglass, Erika J. , Dangott, Bryan, Nakhleh, Raouf E. , Narula, Tathagat , Patel, Parag C. , Lyle, Melissa , Heckman, Alexander , Leoni-Moreno, Juan Carlos, Steidley, D. Eric , Hardaway, Brian , Abbas, Mohsin, Friedman, Paul A. , Carter, Rickey E. , Yamani, Mohamad H. , Douglass, Erika J , Dangott, Bryan J, Narula, Tathagat , Heckman, Alexander J, Leoni-Moreno, Juan C, Attia, Zachi I , Lopez-Jimenez, Francisco , Yamani, Mohamad, Carter, Rickey E , Adedinsewo, Demilade A , Hardway, Heather , Johnson, Patrick W. , Goswami, Rohan , Arsanjani, Reza , Behfar, Atta , Attia, Zachi I. , López-Jiménez, Francisco , Noseworthy, Peter A.

European Heart Journal - Digital Health | January 13, 2023 | Volume: 4 | Issue: 2 | Pages: 71-80

10.1093/ehjdh/ztad001 Get It

Abstract Aims Current non-invasive screening methods for cardiac allograft rejection have shown limited discrimination and are yet to be broadly integrated into heart transplant care. Given electrocardiogram (ECG) changes have been reported with severe cardiac allograft rejection, this study aimed to develop a deep-learning model, a form of artificial intelligence, to detect allograft rejection using the 12-lead ECG (AI-ECG). Methods and results Heart transplant recipients were identified across three Mayo Clinic sites between 1998 and 2021. Twelve-lead digital ECG data and endomyocardial biopsy results were extracted from medical records. Allograft rejection was defined as moderate or severe acute cellular rejection (ACR) based on International Society for Heart and Lung Transplantation guidelines. The extracted data (7590 unique ECG-biopsy pairs, belonging to 1427 patients) was partitioned into training (80%), validation (10%), and test sets (10%) such that each patient was included in only one partition. Model performance metrics were based on the test set (n = 140 patients; 758 ECG-biopsy pairs). The AI-ECG detected ACR with an area under the receiver operating curve (AUC) of 0.84 [95% confidence interval (CI): 0.78–0.90] and 95% (19/20; 95% CI: 75–100%) sensitivity. A prospective proof-of-concept screening study (n = 56; 97 ECG-biopsy pairs) showed the AI-ECG detected ACR with AUC = 0.78 (95% CI: 0.61–0.96) and 100% (2/2; 95% CI: 16–100%) sensitivity. Conclusion An AI-ECG model is effective for detection of moderate-to-severe ACR in heart transplant recipients. Our findings could improve transplant care by providing a rapid, non-invasive, and potentially remote screening option for cardiac allograft function.