Abstract Lung transplant recipients are at higher risk of developing COVID-19 infection compared to other solid organ transplants. The risk further increases in the unvaccinated patients. We present a case of a 43-year-old male who underwent bilateral sequential lung transplantation for pulmonary alveolar microlithiasis (PAM) and had an uneventful recovery. However, two years post-transplantation, the patient developed chronic lung allograft dysfunction (CLAD) with bronchiolitis obliterans syndrome and two episodes of COVID-19 infection. During the second episode of COVID-19 infection, the patient developed sepsis and multi-organ dysfunction ultimately resulting in death. Our case report highlights the increased susceptibility of PAM patients’ post-lung transplant to COVID-19 infection. Continuous follow-up of PAM patients’ post-lung transplantation is necessary to prevent unfavorable outcomes.
Absorbable antibiotic beads for treatment of
LVAD
driveline infections
Abstract Backgound Infections of the left ventricular assist device (LVAD) driveline are a dreaded complication that results in high mortality and morbidity. Method We retrospectively reviewed five consecutive patients with severe continuous‐flow LVAD (HVAD, Heartmate 2, and Heartmate 3) driveline infection. These infections, which developed on an average of 960.4 ± 843.9 days after LVAD placement, were refractory to systemic antibiotics and local wound care. All were treated with extensive surgical debridement, local installation of absorbable antibiotic‐loaded calcium sulfate beads (vancomycin and tobramycin), primary wound closure, and 6 weeks of systemic antibiotics after surgery. Results Four patients had resolution of DLI, and one had a recurrent infection at another part of the driveline 7 months after the complete resolution of the previous site. This patient was successfully treated with debridement and bead placements. Three patients still have their LVADs, while two received orthotopic heart transplants. At the time of the transplant, there was no evidence of gross infection of the LVAD drivelines or pumps. At the average follow‐up time of 425.8 ± 151 days, no patients have an active infection. Conclusion Treatment of LVAD driveline infection with absorbable antibiotic beads with primary wound closure is a viable option and merits further investigation.
Extending donor criteria: successful lung transplantation post ex vivo back table donor pulmonary artery thrombolysis
Abstract Pulmonary embolization in donor lungs is a common finding and found in up to 38% of cases. To expand the pool of organs, transplant centers now utilize lungs, from increased risk donors, that may have pulmonary embolic disease. Modalities of clearing pulmonary artery embolisms are critical to reduce the prevalence of primary graft dysfunction post transplantation. There have been anecdotal cases of pulmonary embolectomy pre and post organ procurement or in vivo and ex vivo thrombolytic therapy performed in donors with massive pulmonary emboli. We report for the first time therapeutic ex vivo thrombolysis on the back table without Ex Vivo Lung Perfusion (EVLP), followed by successful transplantation.
P96: Using Fenestrated Stent to Increase the Flow of ECMO of Superior Vena Cava Compression Syndrome
Abstract Aims We sought to investigate the outcomes of heart transplant patients supported with Impella 5.5 temporary mechanical circulatory support. Methods and results Patient demographics, perioperative data, hospital timeline, and haemodynamic parameters were followed during initial admission, Impella support, and post-transplant period. Vasoactive-inotropic score, primary graft failure, and complications were recorded. Between March 2020 and March 2021, 16 advanced heart failure patients underwent Impella 5.5 temporary left ventricular assist device support through axillary approach. Subsequently, all these patients had heart transplantation. All patients were either ambulatory or chair bound during their temporary mechanical circulatory support until heart transplantation. Patients were kept on Impella support median of 19 days (3–31) with the median lactate dehydrogenase level of 220 (149–430). All Impella devices were removed during heart transplantation. During Impella support, patients had improved renal function with median creatinine serum level of 1.55 mg/dL decreased to 1.25 (P = 0.007), pulmonary artery pulsatility index scores increased from 2.56 (0.86–10) to 4.2 (1.3–10) (P = 0.048), and right ventricular function improved (P = 0.003). Patients maintained improved renal function and favourable haemodynamics after their heart transplantation as well. All patients survived without any significant morbidity after their heart transplantation. Conclusions Impella 5.5 temporary left ventricular assist device optimizes care of heart transplant recipients providing superior haemodynamic support, mobility, improved renal function, pulmonary haemodynamics, and right ventricular function. Utilizing Impella 5.5 as a direct bridging strategy to heart transplantation resulted in excellent outcomes.
Transesophageal echocardiography: a tool for intraoperative assessment of coronary blood flow
Abstract Transesophageal echocardiography (TEE) has become an indispensable part of cardiac surgery, but its potential for assessing coronary anatomy and blood flow remains underutilised. This case report presents a case of acute iatrogenic left main coronary artery obstruction following re-operative aortic valve replacement that was promptly diagnosed by intraoperative TEE and managed successfully by Bentall operation. We also emphasise the technique of TEE for coronary evaluation, its caveats and its clinical application during cardiac surgery.
Incidentally Discovered Cor Triatriatum Sinistrum Anomaly During Heart Transplant