Abstract Glioblastoma (GBM), isocitrate dehydrogenase wild-type (IDHwt) and central nervous system diffuse large B-cell lymphoma (CNS-DLBCL) are aggressive brain tumors with overlapping MRI features, yet distinct treatment approaches. Noninvasive tools are needed to aid in differential diagnosis. Deep learning on T1 postcontrast and T2-weighted MRI sequences were used to differentiate GBM and CNS-DLBCL. A three-stage temporal study design was utilized. Model development was performed on 146 patients with CNS-DLBCL and 146 age-matched, sex-matched, and MRI year–matched patients with GBM diagnosed at Mayo Clinic between 1998 and 2019. Models were tested on independent temporal test cohorts. Initial testing included 240 independent GBM diagnosed at Mayo Clinic between 1998 and 2019. The prospective test cohort included 37 patients with CNS-DLBCL and 256 patients with GBM diagnosed at Mayo Clinic after January 1, 2020, and 36 patients with CNS-DLBCL diagnosed at an external institution. Of the patients diagnosed at Mayo Clinic, 47% had MRIs generated from non-Mayo institutions. Two different model approaches were compared: (i) ensemble approach using area under the receiver operating characteristic curve (AUC) and cross-validation for model selection and (ii) loss approach minimizing cross-entropy loss and cross-validation to evaluate prediction performance. The AUCs on the prospective test cohort were 0.84 [95% confidence interval (CI), 0.78–0.90] and 0.83 (95% CI, 0.77–0.88) for the ensemble and loss approaches, respectively. Stability of ensemble prediction improved with the increasing number of models. Stratified AUC analysis demonstrated consistent performance across sex and age. We utilized a robust temporal study design and applied 2 different analytic approaches to develop a classification model. The findings confirm the feasibility of using MRI-based deep learning models to differentiate GBM from CNS-DLBCL. Significance: GBM, IDHwt and CNS-DLBCL are aggressive brain tumors with overlapping MRI features, yet distinct treatment approaches. Noninvasive tools are needed to aid in differential diagnosis. We developed MRI-based deep learning models to differentiate GBM, IDHwt from CNS-DLBCL using a rigorous three-stage temporal design that included prospective validation. The model AUC on a prospective cohort was 0.84.
Accelerometer‐Measured Behavior Patterns in Incident Cerebrovascular Disease: Insights for Preventative Monitoring From the UK Biobank
Background The goal was to compare patterns of physical activity (PA) behaviors (sedentary behavior [SB], light PA, moderate‐to‐vigorous PA [MVPA], and sleep) measured via accelerometers for 7 days between patients with incident cerebrovascular disease (CeVD) (n=2141) and controls (n=73 938). Methods and Results In multivariate models, cases spent 3.7% less time in MVPA (incidence rate ratio [IRR], 0.963 [95% CI, 0.929–0.998]) and 1.0% more time in SB (IRR, 1.010 [95% CI, 1.001–1.018]). Between 12 and 24 months before diagnosis, cases spent more time in SB (IRR, 1.028 [95% CI, 1.001–1.057]). Within the year before diagnosis, cases spent less time in MVPA (IRR, 0.861 [95% CI, 0.771–0.964]). Although SB time was not associated with CeVD risk, MVPA time, both total min/d (hazard ratio [HR], 0.998 [95% CI, 0.997–0.999]) and guideline threshold adherence (≥150 min/wk) (HR, 0.909 [95% CI, 0.827–0.998]), was associated with decreased CeVD risk. Comorbid burden had a significant partial mediation effect on the relationship between MVPA and CeVD. Cases slept more during 12:00 to 17:59 hours (IRR, 1.091 [95% CI, 1.002–1.191]) but less during 0:00 to 5:59 hours (IRR, 0.984 [95% CI, 0.977–0.992]). No between‐group differences were significant at subgroup analysis. Conclusions Daily behavior patterns were significantly different in patients before CeVD. Although SB was not associated with CeVD risk, the association between MVPA and CeVD risk is partially mediated by comorbid burden. This study has implications for understanding observable behavior patterns in cerebrovascular dysfunction and may help in developing remote monitoring strategies to prevent or reduce cerebrovascular decline.
Mitigating Bias in Radiology Machine Learning: 1. Data Handling
There is a growing demand for high-resolution (HR) medical images for both clinical and research applications. Image quality is inevitably traded off with acquisition time, which in turn impacts patient comfort, examination costs, dose, and motion-induced artifacts. For many image-based tasks, increasing the apparent spatial resolution in the perpendicular plane to produce multi-planar reformats or 3D images is commonly used. Single-image super-resolution (SR) is a promising technique to provide HR images based on deep learning to increase the resolution of a 2D image, but there are few reports on 3D SR. Further, perceptual loss is proposed in the literature to better capture the textural details and edges versus pixel-wise loss functions, by comparing the semantic distances in the high-dimensional feature space of a pre-trained 2D network (e.g., VGG). However, it is not clear how one should generalize it to 3D medical images, and the attendant implications are unclear. In this paper, we propose a framework called SOUP-GAN: Super-resolution Optimized Using Perceptual-tuned Generative Adversarial Network (GAN), in order to produce thinner slices (e.g., higher resolution in the ‘Z’ plane) with anti-aliasing and deblurring. The proposed method outperforms other conventional resolution-enhancement methods and previous SR work on medical images based on both qualitative and quantitative comparisons. Moreover, we examine the model in terms of its generalization for arbitrarily user-selected SR ratios and imaging modalities. Our model shows promise as a novel 3D SR interpolation technique, providing potential applications for both clinical and research applications.
PurposeOrgan segmentation of computed tomography (CT) imaging is essential for radiotherapy treatment planning. Treatment planning requires segmentation not only of the affected tissue, but nearby healthy organs‐at‐risk, which is laborious and time‐consuming. We present a fully automated segmentation method based on the three‐dimensional (3D) U‐Net convolutional neural network (CNN) capable of whole abdomen and pelvis segmentation into 33 unique organ and tissue structures, including tissues that may be overlooked by other automated segmentation approaches such as adipose tissue, skeletal muscle, and connective tissue and vessels. Whole abdomen segmentation is capable of quantifying exposure beyond a handful of organs‐at‐risk to all tissues within the abdomen.MethodsSixty‐six (66) CT examinations of 64 individuals were included in the training and validation sets and 18 CT examinations from 16 individuals were included in the test set. All pixels in each examination were segmented by image analysts (with physician correction) and assigned one of 33 labels. Segmentation was performed with a 3D U‐Net variant architecture which included residual blocks, and model performance was quantified on 18 test cases. Human interobserver variability (using semiautomated segmentation) was also reported on two scans, and manual interobserver variability of three individuals was reported on one scan. Model performance was also compared to several of the best models reported in the literature for multiple organ segmentation.ResultsThe accuracy of the 3D U‐Net model ranges from a Dice coefficient of 0.95 in the liver, 0.93 in the kidneys, 0.79 in the pancreas, 0.69 in the adrenals, and 0.51 in the renal arteries. Model accuracy is within 5% of human segmentation in eight of 19 organs and within 10% accuracy in 13 of 19 organs.ConclusionsThe CNN approaches the accuracy of human tracers and on certain complex organs displays more consistent prediction than human tracers. Fully automated deep learning‐based segmentation of CT abdomen has the potential to improve both the speed and accuracy of radiotherapy dose prediction for organs‐at‐risk.