Back to Authors

Philbrick, Kenneth A.

https://orcid.org/0000-0003-1424-6987

Mayo Clinic

Mayo Clinic

Citations 6

Description and evaluation of a self-operated waist measurement device
Song, Yilin , Philbrick, Kenneth A. , Weston, Alexander D. , Potretzke, Theodora A. , Lytle, Kelli A. , Jensen, Teresa B. , Jensen, Michael D.

BMJ Innovations | April 25, 2024 | Volume: 10 | Issue: 3 | Pages: 88-95

10.1136/bmjinnov-2023-001162 Get It

Background National guidelines recommend that waist circumference (WC) be measured in patients with a body mass index (BMI) 27–35 kg/m2. Unfortunately, perhaps due to logistical reasons, WC is seldom measured in clinical settings. Herein, we describe the performance of a self-operated waist measurement device (SOWMD) as a potential means to overcome barriers to measuring WC. Materials and methods Ten volunteers underwent WC measures by professionals and SOWMD on 5 separate days to assess the reproducibility and accuracy. We then compared SOWMD measures with CT-derived fat content by recruiting 81 patients scheduled for a diagnostic abdominal CT scan. Results There was no difference between professionally measured and SOWMD-measured WC; the intraindividual coefficient of variation over the 5 days was between 0.4% and 2.2%. The WC measured manually, by SOWMD and CT scan were highly correlated (r=0.90–0.92, all p<0.001). The minimal WC measured by SOWMD was a better predictor (r=0.81 for all patients, r=0.87 for men, both p<0.001) of CT-measured visceral adipose tissue volume than other approaches. The minimal WC measured by SOWMD was correlated with fasting plasma glucose (r=0.40, p<0.05), triglyceride (r=0.41, p<0.01) and high-density cholesterol (r=−0.49, p<0.001) concentrations. Conclusion SOWMD is a reproducible, accurate and convenient way to measure WC that can provide added value for health care providers when combined with BMI information.
SOUP-GAN: Super-Resolution MRI Using Generative Adversarial Networks
Zhang, Kuan , Philbrick, Kenneth A. , Conte, Gian Marco , Sobek, Joseph D. , Philbrick, Kenneth, Conte, Gian Marco , Hu, Haoji Roland , Rouzrokh, Pouria , Erickson, Bradley J.

Tomography | March 24, 2022 | Volume: 8 | Issue: 2 | Pages: 905-919

10.3390/tomography8020073 Get It

There is a growing demand for high-resolution (HR) medical images for both clinical and research applications. Image quality is inevitably traded off with acquisition time, which in turn impacts patient comfort, examination costs, dose, and motion-induced artifacts. For many image-based tasks, increasing the apparent spatial resolution in the perpendicular plane to produce multi-planar reformats or 3D images is commonly used. Single-image super-resolution (SR) is a promising technique to provide HR images based on deep learning to increase the resolution of a 2D image, but there are few reports on 3D SR. Further, perceptual loss is proposed in the literature to better capture the textural details and edges versus pixel-wise loss functions, by comparing the semantic distances in the high-dimensional feature space of a pre-trained 2D network (e.g., VGG). However, it is not clear how one should generalize it to 3D medical images, and the attendant implications are unclear. In this paper, we propose a framework called SOUP-GAN: Super-resolution Optimized Using Perceptual-tuned Generative Adversarial Network (GAN), in order to produce thinner slices (e.g., higher resolution in the ‘Z’ plane) with anti-aliasing and deblurring. The proposed method outperforms other conventional resolution-enhancement methods and previous SR work on medical images based on both qualitative and quantitative comparisons. Moreover, we examine the model in terms of its generalization for arbitrarily user-selected SR ratios and imaging modalities. Our model shows promise as a novel 3D SR interpolation technique, providing potential applications for both clinical and research applications.
Association between Visceral Adipose Tissue and Non-Alcoholic Steatohepatitis Histology in Patients with Known or Suspected Non-Alcoholic Fatty Liver Disease
Idılman, Ilkay S. , Low, Hsien Min , Gidener, Tolga , Philbrick, Kenneth A. , Mounajjed, Taofic, Li, Jiahui , Yin, Meng , Venkatesh, Sudhakar K. , Philbrick, Kenneth, Venkatesh, Sudhakar K , Yin, Meng , Gidener, Tolga , Li, Jiahui , Allen, Alina M.

Journal of Clinical Medicine | June 9, 2021 | Volume: 10 | Issue: 12 | Pages: 2565

10.3390/jcm10122565 Get It

(1) Purpose: To determine the association between visceral adipose tissue (VAT) and proton density fat fraction (PDFF) with magnetic resonance imaging (MRI), and hepatic steatosis (HS), non-alcoholic steatohepatitis (NASH) and hepatic fibrosis (HF) in patients with known or suspected non-alcoholic fatty liver disease (NAFLD). (2) Methods: 135 subjects that had a liver biopsy performed within 3 months (bariatric cohort) or 1 month (NAFLD cohort) of an MRI exam formed the study group. VAT volume was quantified at L2-L3 level on opposed-phase images with signal intensity-based painting using a semi-quantitative software. Liver PDFF and pancreas PDFF were calculated on fat fraction maps. Liver volume (Lvol) and spleen volume (Svol) were also calculated using a semi-automated 3D volume tool available on PACS. A histological analysis was performed by an expert hepatopathologist blinded to imaging findings. (3) Results: The mean Lvol, Svol, liver PDFF, pancreas PDFF and VAT of the study population were 2492.2 mL, 381.6 mL, 13.2%, 12.7% and 120.6 mL, respectively. VAT showed moderate correlation with liver PDFF (r = 0.41, p < 0.001) and weak correlation with Lvol (r = 0.38, p < 0.001), Svol (r = 0.20, p = 0.025) and pancreas PDFF (rs = 0.29, p = 0.001). VAT, Lvol and liver PDFF were significantly higher in patients with HS (p < 0.001), NASH (p < 0.05) and HF (p < 0.05). VAT was also significantly higher in the presence of lobular inflammation (p = 0.019) and hepatocyte ballooning (p = 0.001). The cut-off VAT volumes for predicting HS, NASH and HF were 101.8 mL (AUC, 0.7), 111.8 mL (AUC, 0.64) and 111.6 mL (AUC, 0.66), respectively. (4) Conclusion: The MRI determined VAT can be used for predicting the presence of HS, NASH and HF in patients with known or suspected NAFLD.
Complete abdomen and pelvis segmentation using U‐net variant architecture
Weston, Alexander D. , Korfiatis, Panagiotis , Philbrick, Kenneth A. , Conte, Gian Marco , Kostandy, Petro, Sakinis, Thomas, Zeinoddini, Atefeh , Boonrod, Arunnit, Moynagh, Michael R., Takahashi, Naoki , Moynagh, Michael, Conte, Gian Marco , Takahashi, Naoki , Zeinoddini, Atefeh, Erickson, Bradley J.

Medical Physics | August 2, 2020 | Volume: 47 | Issue: 11 | Pages: 5609-5618

10.1002/mp.14422 Get It

PurposeOrgan segmentation of computed tomography (CT) imaging is essential for radiotherapy treatment planning. Treatment planning requires segmentation not only of the affected tissue, but nearby healthy organs‐at‐risk, which is laborious and time‐consuming. We present a fully automated segmentation method based on the three‐dimensional (3D) U‐Net convolutional neural network (CNN) capable of whole abdomen and pelvis segmentation into 33 unique organ and tissue structures, including tissues that may be overlooked by other automated segmentation approaches such as adipose tissue, skeletal muscle, and connective tissue and vessels. Whole abdomen segmentation is capable of quantifying exposure beyond a handful of organs‐at‐risk to all tissues within the abdomen.MethodsSixty‐six (66) CT examinations of 64 individuals were included in the training and validation sets and 18 CT examinations from 16 individuals were included in the test set. All pixels in each examination were segmented by image analysts (with physician correction) and assigned one of 33 labels. Segmentation was performed with a 3D U‐Net variant architecture which included residual blocks, and model performance was quantified on 18 test cases. Human interobserver variability (using semiautomated segmentation) was also reported on two scans, and manual interobserver variability of three individuals was reported on one scan. Model performance was also compared to several of the best models reported in the literature for multiple organ segmentation.ResultsThe accuracy of the 3D U‐Net model ranges from a Dice coefficient of 0.95 in the liver, 0.93 in the kidneys, 0.79 in the pancreas, 0.69 in the adrenals, and 0.51 in the renal arteries. Model accuracy is within 5% of human segmentation in eight of 19 organs and within 10% accuracy in 13 of 19 organs.ConclusionsThe CNN approaches the accuracy of human tracers and on certain complex organs displays more consistent prediction than human tracers. Fully automated deep learning‐based segmentation of CT abdomen has the potential to improve both the speed and accuracy of radiotherapy dose prediction for organs‐at‐risk.
Automated Abdominal Segmentation of CT Scans for Body Composition Analysis Using Deep Learning
Weston, Alexander D. , Korfiatis, Panagiotis , Kline, Timothy L. , Philbrick, Kenneth A. , Kostandy, Petro, Sakinis, Tomas , Sugimoto, Motokazu , Takahashi, Naoki , Takahashi, Naoki , Erickson, Bradley J. , Weston, Alexander D

Radiology | December 26, 2018 | Volume: 290 | Issue: 3 | Pages: 669-679

10.1148/radiol.2018181432 Get It

What Does Deep Learning See? Insights From a Classifier Trained to Predict Contrast Enhancement Phase From CT Images
Philbrick, Kenneth A. , Yoshida, Kotaro , Inoue, Dai , Akkus, Zeynettin , Kline, Timothy L. , Weston, Alexander D. , Korfiatis, Panagiotis , Takahashi, Naoki , Akkus, Zeynettin , Takahashi, Naoki , Erickson, Bradley J.

American Journal of Roentgenology | November 7, 2018 | Volume: 211 | Issue: 6 | Pages: 1184-1193

10.2214/ajr.18.20331 Get It