Back to Authors

Cetta, Frank

0009-0006-7987-502X

Mayo Clinic

Mayo Clinic

Citations 63

Incidence, morphology, and progression of bicuspid aortic valve in pediatric and young adult subjects with coexisting congenital heart defects
Poterucha, Joseph T., Johnson, Jonathan N. , Craviari, Cecilia , Nienaber, Thomas , Palfreeman, Jared, Cetta, Frank , Hagler, Donald J. , Niaz, Talha

Congenital Heart Disease | November 28, 2016 | Volume: 12 | Issue: 3 | Pages: 261-269

10.1111/chd.12429 Get It

Intravascular and hybrid intraoperative stent placement for baffle obstruction in transposition of the great arteries after atrial switch
Poterucha, Joseph T., Taggart, Nathaniel W. , Johnson, Jonathan N. , Cannon, Bryan C. , Hagler, Donald J. , Cetta, Frank , Cabalka, Allison K. , Dearani, Joseph A. , Taggart, Nathaniel W

Catheterization and Cardiovascular Interventions | October 27, 2016 | Volume: 89 | Issue: 2 | Pages: 306-314

10.1002/ccd.26783 Get It

ObjectivesTo report our experience with intravascular and hybrid intra‐operative stent placement for baffle obstruction in patients with complete transposition of the great arteries (TGA) after the atrial switch (Mustard/Senning) operation.BackgroundVenous baffle obstruction is a challenging complication after atrial switch operation in patients with TGA. Traditional treatment options include intravascular stenting or surgery.MethodsA retrospective analysis of Mayo Clinic's electronic medical record was completed to identify consecutive pediatric and adult patients with TGA after atrial switch who underwent baffle stent implantation from 1994 to 2015.ResultsOverall, 64 patients were referred for cardiac catheterization, in whom 47 (73%) were noted to have hemodynamic and angiographic evidence of baffle obstruction. A total of 20 patients mean age 33 (range: 8–46) years old underwent stent implantation of baffle stenosis at a mean of 33 (range: 7.5–45) years after initial atrial switch operation (Mustard, n = 19; Senning, n = 1). Overall, 27 baffles were stented in 20 patients via the following approaches: intravascular (17); hybrid surgical (3); staged intravascular & hybrid (2). Sites of stent placement were: superior vena cava (SVC) (13); inferior vena cava (IVC) (9); pulmonary venous baffle (5). Three patients had stent placement in the SVC and IVC baffles during the same procedure. Procedural adverse events occurred in 2/22 cases (9%) including creation of unintentional baffle leak (n = 1) and stent migration (n = 1). There was no procedure‐related mortality. At follow‐up (median 2, range 0.02–10 years), significantly improved NYHA class and mean Doppler baffle gradient were demonstrated (P < 0.05). Mild baffle re‐stenosis (mean Doppler gradient; 2–3 mmHg) occurred in two patients who have not required re‐intervention. Trivial baffle leak was noted in four patients. Baffle re‐intervention was only occurred in one patient. One patient with pre‐procedural Class IV symptoms died 3.5 months after stent implantation.ConclusionsThis study is the largest reported experience of intravascular and intra‐operative hybrid stent placement for patients with TGA after atrial switch. Transcatheter and minimally invasive hybrid intraoperative surgical stent placement are an effective strategy for relief of systemic and pulmonary venous baffle obstruction. © 2016 Wiley Periodicals, Inc.
Sudden cardiac death and late arrhythmias after the Fontan operation
Pundi, Kavitha N., Pundi, Krishna , Johnson, Jonathan N. , Driscoll, David J. , Wackel, Philip L. , Cetta, Frank , Cannon, Bryan C. , Li, Zhuo , Pundi, Krishna N, Dearani, Joseph A. , Li, Zhuo Ya , McLeod, Christopher J. , Pundi, Krishna

Congenital Heart Disease | August 22, 2016 | Volume: 12 | Issue: 1 | Pages: 17-23

10.1111/chd.12401 Get It

Heart transplantation after Fontan: Results from a surgical Fontan cohort
Pundi, Kavitha N., Pundi, Krishna , Driscoll, David J. , Dahl, S, Mora, Bassem N., Daly, Richard C. , Cetta, Frank , Johnson, Jonathan N. , Li, Zhuo , Dahl, Sonja H, O'Leary, Patrick W, Dearani, Joseph A. , Li, Zhuo Ya , O’Leary, Patrick , Pundi, Krishna

Pediatric Transplantation | July 11, 2016 | Volume: 20 | Issue: 8 | Pages: 1087-1092

10.1111/petr.12753 Get It

AbstractWe performed a retrospective review of outcomes after heart transplantation during long‐term follow‐up of a surgical cohort of 1138 Fontan patients who were followed at the Mayo Clinic. Follow‐up information was obtained from medical records and a clinical questionnaire that was mailed to patients not known to be deceased at the initiation of the study. Forty‐four of 1138 Fontan patients with initial or subsequent evaluation at Mayo had cardiac transplantation between 1988 and 2014 (mean age at transplantation was 23.2 ± 12 yr, median was 19.8 yr; mean interval between Fontan and transplantation was 13.0 ± 7.7 yr, median was 13.1 yr). Two patients had combined organ transplantation (one heart–lung, one heart–liver). Twelve of the 44 (27%) patients had PLE prior to transplantation. There was no difference in post‐bypass Fontan pressures or incidence of late reoperations for AVV repair/replacement between transplanted and non‐transplanted patients. There were 16 (36%) deaths in the transplantation cohort; seven occurred within 30 days of transplantation. Overall one, five, 10, and 15 yr post‐transplantation survival was 80%, 72%, 69%, and 55%, respectively. Although this is a challenging group of patients, intermediate‐term results suggest that cardiac transplantation remains a reasonable option for patients with a failed Fontan circulation.
Long‐term follow‐up after PFO device closure
Taggart, Nathaniel W. , Reeder, Guy S., Lennon, Ryan J. , Slusser, Joshua P. , Freund, Monique , Cetta, Frank , Hagler, Donald J. , Freund, Monique A, Cabalka, Allison K. , Taggart, Nathaniel W

Catheterization and Cardiovascular Interventions | March 31, 2016 | Volume: 89 | Issue: 1 | Pages: 124-133

10.1002/ccd.26518 Get It

ObjectivesTo describe medium‐ to long‐term follow‐up of patients undergoing device closure of patent foramen ovale (PFO) for stroke or transient ischemic attack (TIA).BackgroundTranscatheter device closure of PFO continues to be used for secondary prevention of cryptogenic stroke or TIA, but data are lacking regarding long‐term outcomes.MethodsWe reviewed the Mayo Clinic Rochester PFO database for patients who underwent device closure of PFO for secondary prevention of stroke/TIA from December 2001 to June 2012. Demographic, clinical, procedural, and follow‐up data were reviewed. Recurrence rate of stroke/TIA were calculated. Data were analyzed to identify risk factors of recurrent neurologic events.ResultsSeven hundred and thirty patients (mean age 53 years; 40% female) were included in our study. Most patients (72%) had cryptogenic stroke as their qualifying event for PFO closure. There were no procedure‐related deaths or strokes. The most commonly used device was the Amplatzer Septal Occluder (82%). Median follow‐up was 6 years. A 3.9% of patients had documented residual right‐to‐left shunting at last echocardiogram. Recurrent stroke and/or TIA were reported in 45 patients, (6.3% of patients with follow‐up data). Patients who experienced recurrent stroke/TIA were older and had a higher rate of diabetes and hypertension than those who did not. The presence of residual shunt did not correlate with risk of recurrent events.ConclusionsDevice closure of PFO can be performed safely with very good long‐term resolution of atrial shunting. Recurrent neurologic events after PFO closure may reflect additional comorbid risk factors unrelated to the potential for paradoxical embolism. © 2016 Wiley Periodicals, Inc.
Improved Ventricular Function after TEE-guided Cardioversion of Atrial Arrhythmias in Patients after the Fontan Operation
Poterucha, Joseph T., Egbe, Alexander C. , Johnson, Jonathan N. , Wackel, Phillip L., Cannon, Bryan C. , Eidem, Benjamin W., Cetta, Frank , Niaz, Talha

Congenital Heart Disease | March 31, 2016 | Volume: 11 | Issue: 6 | Pages: 578-583

10.1111/chd.12339 Get It

Contraception Practices and Pregnancy Outcome in Patients after Fontan Operation
Pundi, Kavitha N., Pundi, Krishna , Johnson, Jonathan N. , Bonnichsen, Crystal R. , Phillips, Sabrina D. , Canobbio, Mary C., Driscoll, David J. , Cetta, Frank , Dearani, Joseph A. , Canobbio, Mary M., Pundi, Krishna

Congenital Heart Disease | August 4, 2015 | Volume: 11 | Issue: 1 | Pages: 63-70

10.1111/chd.12291 Get It

Is Aortic Valve Leaflet Morphology Predictive of Outcome in Pediatric Aortic Valve Stenosis?
Bowman, Jessica, Cao, Yumei , Tweddell, James S., Simpson, Pippa , Cetta, Frank , Pelech, Andrew N. , Bowman, Jessica L, Loomba, Rohit , Dearani, Joseph A.

Congenital Heart Disease | July 29, 2015 | Volume: 10 | Issue: 6 | Pages: 552-560

10.1111/chd.12278 Get It

Transcatheter closure of postmyocardial infarction, iatrogenic, and postoperative ventricular septal defects: The Mayo Clinic experience
Egbe, Alexander C. , Poterucha, Joseph T., Rihal, Charanjit S. , Taggart, Nathaniel W. , Cetta, Frank , Pollak, Peter , Reeder, Guy S., Hagler, Donald J. , Cabalka, Allison K. , Pollak, Peter M, Rihal, Charanjit S. , Taggart, Nathaniel W

Catheterization and Cardiovascular Interventions | May 29, 2015 | Volume: 86 | Issue: 7 | Pages: 1264-1270

10.1002/ccd.25989 Get It

Objectives To determine event‐free survival after transcatheter closure of ventricular septal defect (VSD), and to identify predictors of adverse events (AE) in post myocardial infarction VSD (post‐MI VSD) subgroup. Background There are limited data on mid‐term follow‐up after transcatheter VSD closure. Methods Retrospective review of 27 cases of transcatheter VSD closure (post‐MI = 18 and non‐ischemic = 9) performed from 1999 to 2013. We defined AE as death, device embolization, hemolysis requiring blood transfusion, heart block and reintervention. Results In the post‐MI VSD subgroup, mean age and follow‐up was 69 ± 11 and 7.3 ± 7 years, respectively. AE occurred in 8 (44%) patients (death‐3, device embolization‐1, hemolysis‐1, surgical VSD closure‐2, reintervention‐1). Event‐free survival was 56% at 1 month and 5 years, and all AE occurred in the periprocedural period. Cardiogenic shock (HR: 3.21, CI: 1.82–5.41, P = 0.002), and VSD closure in acute phase (HR: 2.14, CI: 1.12–4.31, P = 0.004) were independent predictors of AE. In the non‐ischemic VSD subgroup, mean age and follow‐up was 49 ± 15 and 8.7 ± 8 years, respectively. AE occurred in 3 (33%) patients (late death‐1, surgical VSD closure‐2). For the entire cohort, freedom from death was 89% and 85% at 1 month and 5 years, and event‐free survival was 70% and 61% at 1 month and 5 years. Conclusions Transcatheter closure of post‐MI VSD carries a moderate risk of periprocedural complications but low event rates afterwards. By comparison, device closure of non‐ischemic VSD has lower periprocedural morbidity but some patients continued to experience AE during follow‐up. © 2015 Wiley Periodicals, Inc.
Embolization of Veno-venous Collaterals after the Fontan Operation Is Associated with Decreased Survival
Poterucha, Joseph T., Johnson, Jonathan N. , Taggart, Nathaniel W. , Hagler, Donald J. , Driscoll, David J. , Cetta, Frank , Taggart, Nathan W, Cabalka, Allison K. , Taggart, Nathaniel W

Congenital Heart Disease | May 23, 2015 | Volume: 10 | Issue: 5 | Pages: E230-E236

10.1111/chd.12276 Get It